Abdullah Tahir1, Hashim Iqbal1, Muhammad Usman1, Asim Ghaffar2, Awais Hafeez1. 1. Department of Mechatronics and Control Engineering, University of Engineering and Technology Lahore, Faisalabad Campus, Lahore, Pakistan. 2. Department of Mechatronics and Control Engineering, University of Engineering and Technology Lahore, Faisalabad Campus, Lahore, Pakistan. asim.ghaffar@uet.edu.pk.
Abstract
PURPOSE: Effective and efficient haptic guidance is desirable for tele-operated robotic surgery because it has a potential to enhance surgeon's skills, especially in coronary interventions where surgeon loses both an eye-hand coordination and a direct sight to the organ. This paper proposes a novel haptic guidance procedure-both kinesthetic and cutaneous, which solely depends upon X-ray images, for tele-robotic system that assists an efficient navigation of the guidewire towards the target location during a coronary intervention. METHODS: Proposed methodology requires cardiologists to draw virtual fixtures (VFs) on angiograms as a preoperative procedure. During an operation, these VFs direct the guidewire to the desired coronary vessel. For this, the position and orientation of guidewire tip are calculated with respect to VFs' anatomy, using image processing on the real-time 2D fluoroscopic images. The haptic feedbacks are then rendered on to the master device depending on the interaction with attractive and repulsive, guidance and forbidden region VFs. RESULTS: A feasibility study in the laboratory environment is performed by using a webcam as an image acquisition device and a phantom-based coronary vessel model. The subsequent statistical analysis shows that, on an average, a decrease of approx. 37% in task completion time is observed with haptic feedback. Moreover, haptic guidance is found effective for most difficult branch, whereas there is a minimal significance of such haptics for the easiest branch. CONCLUSIONS: The proposed haptic guidance procedure may assist cardiologists for an efficient and effective guidewire navigation during a surgical procedure. The cutaneous haptics (vibration feedback) is found more helpful in coronary interventions compared with kinesthetic haptics (force feedback).
PURPOSE: Effective and efficient haptic guidance is desirable for tele-operated robotic surgery because it has a potential to enhance surgeon's skills, especially in coronary interventions where surgeon loses both an eye-hand coordination and a direct sight to the organ. This paper proposes a novel haptic guidance procedure-both kinesthetic and cutaneous, which solely depends upon X-ray images, for tele-robotic system that assists an efficient navigation of the guidewire towards the target location during a coronary intervention. METHODS: Proposed methodology requires cardiologists to draw virtual fixtures (VFs) on angiograms as a preoperative procedure. During an operation, these VFs direct the guidewire to the desired coronary vessel. For this, the position and orientation of guidewire tip are calculated with respect to VFs' anatomy, using image processing on the real-time 2D fluoroscopic images. The haptic feedbacks are then rendered on to the master device depending on the interaction with attractive and repulsive, guidance and forbidden region VFs. RESULTS: A feasibility study in the laboratory environment is performed by using a webcam as an image acquisition device and a phantom-based coronary vessel model. The subsequent statistical analysis shows that, on an average, a decrease of approx. 37% in task completion time is observed with haptic feedback. Moreover, haptic guidance is found effective for most difficult branch, whereas there is a minimal significance of such haptics for the easiest branch. CONCLUSIONS: The proposed haptic guidance procedure may assist cardiologists for an efficient and effective guidewire navigation during a surgical procedure. The cutaneous haptics (vibration feedback) is found more helpful in coronary interventions compared with kinesthetic haptics (force feedback).
Authors: Jing Ren; Rajni V Patel; Kenneth A McIsaac; Gerard Guiraudon; Terry M Peters Journal: IEEE Trans Med Imaging Date: 2008-08 Impact factor: 10.048
Authors: C-H King; M O Culjat; M L Franco; C E Lewis; E P Dutson; W S Grundfest; J W Bisley Journal: IEEE Trans Haptics Date: 2009-03-06 Impact factor: 2.487