Literature DB >> 18672424

Dynamic 3-D virtual fixtures for minimally invasive beating heart procedures.

Jing Ren1, Rajni V Patel, Kenneth A McIsaac, Gerard Guiraudon, Terry M Peters.   

Abstract

Two-dimensional or 3-D visual guidance is often used for minimally invasive cardiac surgery and diagnosis. This visual guidance suffers from several drawbacks such as limited field of view, loss of signal from time to time, and in some cases, difficulty of interpretation. These limitations become more evident in beating-heart procedures when the surgeon has to perform a surgical procedure in the presence of heart motion. In this paper, we propose dynamic 3-D virtual fixtures (DVFs) to augment the visual guidance system with haptic feedback, to provide the surgeon with more helpful guidance by constraining the surgeon's hand motions thereby protecting sensitive structures. DVFs can be generated from preoperative dynamic magnetic resonance (MR) or computed tomograph (CT) images and then mapped to the patient during surgery. We have validated the feasibility of the proposed method on several simulated surgical tasks using a volunteer's cardiac image dataset. Validation results show that the integration of visual and haptic guidance can permit a user to perform surgical tasks more easily and with reduced error rate. We believe this is the first work presented in the field of virtual fixtures that explicitly considers heart motion.

Entities:  

Mesh:

Year:  2008        PMID: 18672424     DOI: 10.1109/TMI.2008.917246

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Vision-Based Control of a Handheld Surgical Micromanipulator with Virtual Fixtures.

Authors:  Brian C Becker; Robert A Maclachlan; Louis A Lobes; Gregory D Hager; Cameron N Riviere
Journal:  IEEE Trans Robot       Date:  2013-02-19       Impact factor: 5.567

Review 2.  Surgical simulation in pediatric urologic education.

Authors:  Thomas Sean Lendvay
Journal:  Curr Urol Rep       Date:  2011-04       Impact factor: 3.092

3.  Dimensionality Reduction in Controlling Articulated Snake Robot for Endoscopy Under Dynamic Active Constraints.

Authors:  Ka-Wai Kwok; Kuen Hung Tsoi; Valentina Vitiello; James Clark; Gary C T Chow; Wayne Luk; Guang-Zhong Yang
Journal:  IEEE Trans Robot       Date:  2013-02-01       Impact factor: 5.567

4.  Cardiac X-ray image-based haptic guidance for robot-assisted coronary intervention: a feasibility study.

Authors:  Abdullah Tahir; Hashim Iqbal; Muhammad Usman; Asim Ghaffar; Awais Hafeez
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-01-18       Impact factor: 2.924

5.  Dynamic virtual fixture on the Euclidean group for admittance-type manipulator in deforming environments.

Authors:  Dongwen Zhang; Qingsong Zhu; Jing Xiong; Lei Wang
Journal:  Biomed Eng Online       Date:  2014-04-27       Impact factor: 2.819

6.  A novel flexible virtual fixtures for teleoperation.

Authors:  Guanglong Du; Ping Zhang
Journal:  ScientificWorldJournal       Date:  2014-02-11

7.  Combined 2D and 3D tracking of surgical instruments for minimally invasive and robotic-assisted surgery.

Authors:  Xiaofei Du; Maximilian Allan; Alessio Dore; Sebastien Ourselin; David Hawkes; John D Kelly; Danail Stoyanov
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-02       Impact factor: 2.924

8.  Force quantification and simulation of pedicle screw tract palpation using direct visuo-haptic volume rendering.

Authors:  Esther I Zoller; Balázs Faludi; Nicolas Gerig; Gregory F Jost; Philippe C Cattin; Georg Rauter
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-09-21       Impact factor: 2.924

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.