Literature DB >> 35035293

Initial Evaluation of a Mobile SARS-CoV-2 RT-LAMP Testing Strategy.

Christina M Newman1, Mitchell D Ramuta1, Matthew T McLaughlin1, Roger W Wiseman1, Julie A Karl1, Dawn M Dudley1, Miranda R Stauss2, Robert J Maddox2, Andrea M Weiler2, Mason I Bliss3, Katrina N Fauser2, Luis A Haddock3, Cecilia G Shortreed1, Amelia K Haj1, Molly A Accola4, Anna S Heffron1, Hailey E Bussan1, Matthew R Reynolds3,2, Olivia E Harwood1, Ryan V Moriarty1, Laurel M Stewart1, Chelsea M Crooks3, Trent M Prall1, Emma K Neumann1, Elizabeth D Somsen1, Corrie B Burmeister1, Kristi L Hall1, William M Rehrauer1,4, Thomas C Friedrich3,2, Shelby L O'Connor1,2, David H O'Connor1,2.   

Abstract

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) control in the United States remains hampered, in part, by testing limitations. We evaluated a simple, outdoor, mobile, colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay workflow where self-collected saliva is tested for SARS-CoV-2 RNA. From July 16, 2020, to November 19, 2020, surveillance samples (n = 4704) were collected from volunteers and tested for SARS-CoV-2 at 5 sites. Twenty-one samples tested positive for SARS-CoV-2 by RT-LAMP; 12 were confirmed positive by subsequent quantitative reverse-transcription polymerase chain reaction (qRT-PCR) testing, whereas 8 tested negative for SARS-CoV-2 RNA, and 1 could not be confirmed because the donor did not consent to further molecular testing. We estimated the false-negative rate of the RT-LAMP assay only from July 16, 2020, to September 17, 2020 by pooling residual heat-inactivated saliva that was unambiguously negative by RT-LAMP into groups of 6 or fewer and testing for SARS-CoV-2 RNA by qRT-PCR. We observed a 98.8% concordance between the RT-LAMP and qRT-PCR assays, with only 5 of 421 RT-LAMP-negative pools (2493 total samples) testing positive in the more-sensitive qRT-PCR assay. Overall, we demonstrate a rapid testing method that can be implemented outside the traditional laboratory setting by individuals with basic molecular biology skills and that can effectively identify asymptomatic individuals who would not typically meet the criteria for symptom-based testing modalities.
© 2021 ABRF.

Entities:  

Keywords:  colorimetric LAMP; point-of-care test; saliva-based

Mesh:

Substances:

Year:  2021        PMID: 35035293      PMCID: PMC8730517          DOI: 10.7171/jbt.21-32-03-009

Source DB:  PubMed          Journal:  J Biomol Tech        ISSN: 1524-0215


  47 in total

Review 1.  A review of saliva: normal composition, flow, and function.

Authors:  S P Humphrey; R T Williamson
Journal:  J Prosthet Dent       Date:  2001-02       Impact factor: 3.426

2.  A rapid, sensitive and inexpensive method for detection of grapevine red blotch virus without tissue extraction using loop-mediated isothermal amplification.

Authors:  J Lucina Romero Romero; Gavriela Dena Carver; Patricio Arce Johnson; Keith L Perry; Jeremy R Thompson
Journal:  Arch Virol       Date:  2019-03-20       Impact factor: 2.574

3.  SARS-CoV-2 Viral Load in Upper Respiratory Specimens of Infected Patients.

Authors:  Lirong Zou; Feng Ruan; Mingxing Huang; Lijun Liang; Huitao Huang; Zhongsi Hong; Jianxiang Yu; Min Kang; Yingchao Song; Jinyu Xia; Qianfang Guo; Tie Song; Jianfeng He; Hui-Ling Yen; Malik Peiris; Jie Wu
Journal:  N Engl J Med       Date:  2020-02-19       Impact factor: 91.245

4.  Evaluation of Abbott BinaxNOW Rapid Antigen Test for SARS-CoV-2 Infection at Two Community-Based Testing Sites - Pima County, Arizona, November 3-17, 2020.

Authors:  Jessica L Prince-Guerra; Olivia Almendares; Leisha D Nolen; Jayleen K L Gunn; Ariella P Dale; Sean A Buono; Molly Deutsch-Feldman; Suganthi Suppiah; LiJuan Hao; Yan Zeng; Valerie A Stevens; Kristen Knipe; Justine Pompey; Christine Atherstone; David P Bui; Tracy Powell; Azaibi Tamin; Jennifer L Harcourt; Patricia L Shewmaker; Magdalena Medrzycki; Phili Wong; Shilpi Jain; Alexandra Tejada-Strop; Shannon Rogers; Brian Emery; Houping Wang; Marla Petway; Caitlin Bohannon; Jennifer M Folster; Adam MacNeil; Reynolds Salerno; Wendi Kuhnert-Tallman; Jacqueline E Tate; Natalie J Thornburg; Hannah L Kirking; Khalilullah Sheiban; Julie Kudrna; Theresa Cullen; Kenneth K Komatsu; Julie M Villanueva; Dale A Rose; John C Neatherlin; Mark Anderson; Paul A Rota; Margaret A Honein; William A Bower
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2021-01-22       Impact factor: 17.586

5.  Direct detection of SARS-CoV-2 using non-commercial RT-LAMP reagents on heat-inactivated samples.

Authors:  Alisa Alekseenko; Donal Barrett; Yerma Pareja-Sanchez; Rebecca J Howard; Emilia Strandback; Henry Ampah-Korsah; Urška Rovšnik; Silvia Zuniga-Veliz; Alexander Klenov; Jayshna Malloo; Shenglong Ye; Xiyang Liu; Björn Reinius; Simon J Elsässer; Tomas Nyman; Gustaf Sandh; Xiushan Yin; Vicent Pelechano
Journal:  Sci Rep       Date:  2021-01-19       Impact factor: 4.379

6.  Optimizing direct RT-LAMP to detect transmissible SARS-CoV-2 from primary nasopharyngeal swab samples.

Authors:  Dawn M Dudley; Christina M Newman; Andrea M Weiler; Mitchell D Ramuta; Cecilia G Shortreed; Anna S Heffron; Molly A Accola; William M Rehrauer; Thomas C Friedrich; David H O'Connor
Journal:  PLoS One       Date:  2020-12-31       Impact factor: 3.240

7.  Performance of an Antigen-Based Test for Asymptomatic and Symptomatic SARS-CoV-2 Testing at Two University Campuses - Wisconsin, September-October 2020.

Authors:  Ian W Pray; Laura Ford; Devlin Cole; Christine Lee; John Paul Bigouette; Glen R Abedi; Dena Bushman; Miranda J Delahoy; Dustin Currie; Blake Cherney; Marie Kirby; Geroncio Fajardo; Motria Caudill; Kimberly Langolf; Juliana Kahrs; Patrick Kelly; Collin Pitts; Ailam Lim; Nicole Aulik; Azaibi Tamin; Jennifer L Harcourt; Krista Queen; Jing Zhang; Brett Whitaker; Hannah Browne; Magdalena Medrzycki; Patricia Shewmaker; Jennifer Folster; Bettina Bankamp; Michael D Bowen; Natalie J Thornburg; Kimberly Goffard; Brandi Limbago; Allen Bateman; Jacqueline E Tate; Douglas Gieryn; Hannah L Kirking; Ryan Westergaard; Marie Killerby
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2021-01-01       Impact factor: 35.301

8.  Evaluation of rapid diagnosis of novel coronavirus disease (COVID-19) using loop-mediated isothermal amplification.

Authors:  Yutaro Kitagawa; Yuta Orihara; Rieko Kawamura; Kazuo Imai; Jun Sakai; Norihito Tarumoto; Masaru Matsuoka; Shinichi Takeuchi; Shigefumi Maesaki; Takuya Maeda
Journal:  J Clin Virol       Date:  2020-05-21       Impact factor: 3.168

9.  Rapid detection of novel coronavirus/Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by reverse transcription-loop-mediated isothermal amplification.

Authors:  Laura E Lamb; Sarah N Bartolone; Elijah Ward; Michael B Chancellor
Journal:  PLoS One       Date:  2020-06-12       Impact factor: 3.240

10.  Saliva or Nasopharyngeal Swab Specimens for Detection of SARS-CoV-2.

Authors:  Anne L Wyllie; John Fournier; Arnau Casanovas-Massana; Melissa Campbell; Maria Tokuyama; Pavithra Vijayakumar; Joshua L Warren; Bertie Geng; M Catherine Muenker; Adam J Moore; Chantal B F Vogels; Mary E Petrone; Isabel M Ott; Peiwen Lu; Arvind Venkataraman; Alice Lu-Culligan; Jonathan Klein; Rebecca Earnest; Michael Simonov; Rupak Datta; Ryan Handoko; Nida Naushad; Lorenzo R Sewanan; Jordan Valdez; Elizabeth B White; Sarah Lapidus; Chaney C Kalinich; Xiaodong Jiang; Daniel J Kim; Eriko Kudo; Melissa Linehan; Tianyang Mao; Miyu Moriyama; Ji E Oh; Annsea Park; Julio Silva; Eric Song; Takehiro Takahashi; Manabu Taura; Orr-El Weizman; Patrick Wong; Yexin Yang; Santos Bermejo; Camila D Odio; Saad B Omer; Charles S Dela Cruz; Shelli Farhadian; Richard A Martinello; Akiko Iwasaki; Nathan D Grubaugh; Albert I Ko
Journal:  N Engl J Med       Date:  2020-08-28       Impact factor: 176.079

View more
  4 in total

1.  Self-Sampled Gargle Water Direct RT-LAMP as a Screening Method for the Detection of SARS-CoV-2 Infections.

Authors:  Skaiste Arbaciauskaite; Pouya Babakhani; Natalia Sandetskaya; Dalius Vitkus; Ligita Jancoriene; Dovile Karosiene; Dovile Karciauskaite; Birute Zablockiene; Dirk Kuhlmeier
Journal:  Diagnostics (Basel)       Date:  2022-03-22

2.  SARS-CoV-2 and other respiratory pathogens are detected in continuous air samples from congregate settings.

Authors:  Mitchell D Ramuta; Christina M Newman; Savannah F Brakefield; Miranda R Stauss; Roger W Wiseman; Amanda Kita-Yarbro; Eli J O'Connor; Neeti Dahal; Ailam Lim; Keith P Poulsen; Nasia Safdar; John A Marx; Molly A Accola; William M Rehrauer; Julia A Zimmer; Manjeet Khubbar; Lucas J Beversdorf; Emma C Boehm; David Castañeda; Clayton Rushford; Devon A Gregory; Joseph D Yao; Sanjib Bhattacharyya; Marc C Johnson; Matthew T Aliota; Thomas C Friedrich; David H O'Connor; Shelby L O'Connor
Journal:  medRxiv       Date:  2022-03-30

3.  SARS-CoV-2 and other respiratory pathogens are detected in continuous air samples from congregate settings.

Authors:  David H O'Connor; Shelby L O'Connor; Mitchell D Ramuta; Christina M Newman; Savannah F Brakefield; Miranda R Stauss; Roger W Wiseman; Amanda Kita-Yarbro; Eli J O'Connor; Neeti Dahal; Ailam Lim; Keith P Poulsen; Nasia Safdar; John A Marx; Molly A Accola; William M Rehrauer; Julia A Zimmer; Manjeet Khubbar; Lucas J Beversdorf; Emma C Boehm; David Castañeda; Clayton Rushford; Devon A Gregory; Joseph D Yao; Sanjib Bhattacharyya; Marc C Johnson; Matthew T Aliota; Thomas C Friedrich
Journal:  Nat Commun       Date:  2022-08-11       Impact factor: 17.694

4.  Competitive SNP-LAMP probes for rapid and robust single-nucleotide polymorphism detection.

Authors:  Leland B Hyman; Clare R Christopher; Philip A Romero
Journal:  Cell Rep Methods       Date:  2022-06-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.