| Literature DB >> 35031660 |
Ulyana Bliznyuk1,2, Valentina Avdyukhina3, Polina Borshchegovskaya3,4, Timofey Bolotnik5, Victoria Ipatova3,4, Zoya Nikitina6, Alexander Nikitchenko3, Igor Rodin5,7, Felix Studenikin3,4, Alexander Chernyaev3,4, Dmitry Yurov4.
Abstract
The purpose of this work was to compare the effect of electron and X-ray irradiation on microbiological content and volatile organic compounds in chilled turkey meat. Dose ranges which significantly suppress the pathogenic microflora while maintaining the organoleptic properties of the turkey meat are different for electron and X-ray irradiation. According to the study it is recommended to treat chilled turkey using X-ray irradiation with the dose ranging from 0.5 to 0.75 kGy, while in electron irradiation permissible doses should be within 0.25-1 kGy. Three main groups of volatile compounds: alcohols, ketones, and aldehydes-were found in irradiated and non-irradiated samples of turkey meat. It was found that the total amount of aldehydes, which are responsible for the formation of a specific odor of irradiated meat products, increases exponentially with the increase in the absorbed dose for both types of irradiation. It was established that acetone can be used as a potential marker of the fact of exposure of low-fat meat products to ionizing radiation.Entities:
Year: 2022 PMID: 35031660 PMCID: PMC8760279 DOI: 10.1038/s41598-021-04733-3
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1The electron spectrum N(E) of the accelerator UELR-1-25-T-001.
Figure 2Depth dose distribution in a water layer 5 mm thick during 1 MeV electron treatment from one side. The dashed line is the average thickness of the turkey sample.
Figure 3(a) Computer simulation of the BSV-23 Cu X-ray tube. Red lines are accelerated electrons and green lines are photons. (b) The spectrum of photons N(E) in arb. units at the output of the BSV-23 Cu X-ray tube.
Figure 4Depth dose distribution in a 7 mm thick water layer during two-side X-ray treatment.
Figure 5Dependences of the relative total viable count of microorganisms in chilled turkey meat on the dose of X-ray (black curve) and electron (red curve) radiation.
The content of identified volatile compounds in the turkey samples (mg/kg; n = 3 is the number of repeats, P = 0.95 is the confidence level).
| Class | Name | Control | 0.25 kGy | 0.5 kGy | 1 kGy | 2 kGy | |
|---|---|---|---|---|---|---|---|
| Aldehydes | Pentanal | Electron | 0.028 ± 0.007 | 0.042 ± 0.008 | 0.04 ± 0.01 | 0.05 ± 0.01 | 0.06 ± 0.01 |
| X-ray | 0.023 ± 0.006 | 0.036 ± 0.009 | 0.04 ± 0.01 | 0.07 ± 0.02 | |||
| Hexanal | Electron | 0.21 ± 0.05 | 0.4 ± 0.1 | 0.4 ± 0.1 | 0.4 ± 0.1 | 0.5 ± 0.1 | |
| X-ray | 0.18 ± 0.04 | 0.37 ± 0.09 | 0.36 ± 0.09 | 0.7 ± 0.2 | |||
| Ketones | Acetone | Electron | ND ( ND – Not Detected.) | 0.04 ± 0.01 | 0.04 ± 0.01 | 0.05 ± 0.01 | 0.07 ± 0.02 |
| X-ray | 0.04 ± 0.01 | 0.04 ± 0.01 | 0.041 ± 0.009 | 0.05 ± 0.01 | |||
| 2,3-Butanedione | Electron | 1.5 ± 0.4 | 1.4 ± 0.4 | 0.5 ± 0.1 | 0.4 ± 0.1 | 0.6 ± 0.1 | |
| X-ray | 0.20 ± 0.05 | 0.21 ± 0.05 | 0.26 ± 0.07 | 0.30 ± 0.07 | |||
| 3-Hydroxy-2-butanone | Electron | 0.4 ± 0.1 | 0.18 ± 0.04 | 0.19 ± 0.05 | 0.10 ± 0.02 | 0.07 ± 0.02 | |
| X-ray | 0.28 ± 0.07 | 0.31 ± 0.08 | 0.6 ± 0.1 | 0.6 ± 0.2 | |||
| 6-Methylheptanone-3 | Electron | 0.07 ± 0.02 | 0.04 ± 0.01 | 0.05 ± 0.01 | 0.06 ± 0.01 | 0.07 ± 0.02 | |
| X-ray | 0.08 ± 0.02 | 0.09 ± 0.02 | 0.12 ± 0.03 | 0.21 ± 0.05 | |||
| Alcohols | Isopropanol | Electron | ND | 0.037 ± 0.009 | 0.05 ± 0.01 | 0.053 ± 0.013 | 0.05 ± 0.01 |
| X-ray | 0.08 ± 0.02 | 0.07 ± 0.02 | 0.08 ± 0.02 | 0.09 ± 0.02 | |||
| 2,3-Butanediol | Electron | 0.02 ± 0.004 | 0.020 ± 0.005 | ND | ND | ND | |
| X-ray | 0.22 ± 0.06 | 0.33 ± 0.08 | 0.4 ± 0.1 | 0.5 ± 0.1 | |||
| Hexanol-1 | Electron | 0.07 ± 0.02 | 0.06 ± 0.02 | 0.034 ± 0.008 | 0.04 ± 0.01 | 0.05 ± 0.01 | |
| X-ray | 0.06 ± 0.02 | 0.12 ± 0.03 | 0.14 ± 0.03 | 0.31 ± 0.07 | |||
| 2-Ethylhexanol-1 | Electron | 0.08 ± 0.02 | 0.06 ± 0.01 | 0.05 ± 0.01 | 0.054 ± 0.013 | 0.11 ± 0.03 | |
| X-ray | 0.08 ± 0.03 | 0.09 ± 0.04 | 0.12 ± 0.03 | 0.21 ± 0.03 | |||
ND not detected.
Figure 6Dependence of the concentration of (a) aldehydes and (b) acetone on the dose of electron and X-ray radiation.
Figure 7Dose dependence of the change in the relative concentration of volatile compounds (red curve), acetone (blue curve), aldehydes (green curve) and microorganisms (black curve) in turkey meat after treatment with (a) electron and (b) X-rays.