| Literature DB >> 35022781 |
Jonathan Reyes1, Bernhard Stiehl1, Juanpablo Delgado1, Michael Kinzel1, Kareem Ahmed1.
Abstract
BACKGROUND: Airborne viral pathogens like severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can be encapsulated and transmitted through liquid droplets/aerosols formed during human respiratory events.Entities:
Keywords: COVID-19; aerosols and droplets; face coverings; human respiratory function; social distance study
Mesh:
Substances:
Year: 2022 PMID: 35022781 PMCID: PMC9016420 DOI: 10.1093/infdis/jiab609
Source DB: PubMed Journal: J Infect Dis ISSN: 0022-1899 Impact factor: 7.759
Experiment Specifications
| Equipment | Specifications | Use | Placement |
|---|---|---|---|
| Light source | 532 nm, 150 mJ | Particle illumination | ROI |
| Camera | 5 MP, 30 fps | Capture of particle scatter | 1.52 m from ROI |
| PDI | 0.5 < diameter < 1000 μm | Particle distribution/velocity | ROI |
| APS | 0.3 < diameter < 500 μm | Particle distribution | ROI |
| Cloth face covering | Single layer, 100% cotton | Exhausted particle reduction | Over participant’s nose and mouth |
| Disposable face covering | Triple layer, 15-μm mesh | Exhausted particle reduction | Over participant’s nose and mouth |
Abbreviations: APS, aerodynamic particle sizer; PDI, phase doppler interferometer; ROI, region of interest.
Statistical Participant Information
| Participant | Age, y | Height, ft | Sex | Zero-Exposure Distance, ft (90% CI) | ||
|---|---|---|---|---|---|---|
| No Cover | Cloth Cover | Disposable Cover | ||||
| 1 | 28 | 5.67 | Male | 4.3 (±0.22) | 2.1 (±0.12) | 0.5 (±0.01) |
| 2 | 25 | 5.83 | Male | 4.4 (±0.24) | 2.2 (±0.14) | 0.5 (±0.03) |
| 3 | 26 | 5.58 | Male | 4.3 (±0.19) | 2.0 (±0.20) | 0.5 (±0.01) |
| 4 | 24 | 5.75 | Male | 4.5 (±0.31) | 2.1 (±0.11) | 0.4 (±0.01) |
| 5 | 23 | 5.75 | Male | 4.4 (±0.25) | 1.8 (±0.05) | 0.5 (±0.02) |
| 6 | 29 | 5.67 | Male | 4.4 (±0.23) | 2.0 (±0.18) | 0.5 (±0.01) |
| 7 | 26 | 5.42 | Male | 4.2 (±0.28) | 1.9 (±0.10) | 0.5 (±0.03) |
| 8 | 22 | 5.92 | Male | 4.5 (±0.19) | 2.1 (±0.02) | 0.4 (±0.01) |
| 9 | 30 | 5.75 | Male | 4.1 (±0.22) | 2.0 (±0.04) | 0.5 (±0.01) |
| 10 | 31 | 6 | Male | 4.5 (±0.33) | 2.1 (±0.13) | 0.3 (±0.02) |
| 11 | 27 | 6.08 | Male | 4.5 (±0.26) | 2.2 (±0.14) | 0.5 (±0.03) |
| 12 | 28 | 5.67 | Female | 4.4 (±0.22) | 1.8 (±0.13) | 0.4 (±0.02) |
| 13 | 27 | 5.5 | Female | 4.4 (±0.21) | 1.7 (±0.04) | 0.5 (±0.01) |
| 14 | 21 | 5.58 | Female | 4.5 (±0.30) | 2.1 (±0.15) | 0.5 (±0.02) |
Abbreviation: CI, confidence interval.
Figure 1.Experimental approach: (A) diagram of experimental set up with labeled equipment; and (B) acquisition grid used to obtain distance data.
Summarized Results From All Experimental Test Cases and Participants With 90% Confidence Intervals in Parentheses
| Mode | Face Cover, Type | Average Exhausted Diameter, μm | Maximum Exhausted Distance, ft | Average Exhausted Velocity, m/s | Expelled Volume, mL |
|---|---|---|---|---|---|
| Speech | None | 11.5 (±1.10) | 1.25 (±0.08) | 5.3 (±0.32) | 3.5 (±0.29) |
| Cloth | 1.5 (±0.11) | 0.61 (±0.04) | 1.9 (±0.14) | 0.05 (±4e-3) | |
| Disposable | 0.8 (±0.06) | 0.15 (±0.01) | 0.8 (±0.05) | 0.002 (±2e-4) | |
| Cough | None | 13.2 (±1.30) | 1.37 (±0.09) | 12.1 (±0.74) | 4.3 (±0.41) |
| Cloth | 1.9 (±0.14) | 0.67 (±0.04) | 4.8 (±0.33) | 0.07 (±5e-3) | |
| Disposable | 0.7 (±0.07) | 0.15 (±0.15) | 0.9 (±0.08) | 0.001 (±1e-4) |
Figure 2.Path line images of compiled speech recordings (A) without a face covering; (B) with a cotton cloth covering; and (C) with a 3-layer mesh disposable covering.
Figure 3.Path line images of compiled cough recordings (A) without a face covering; (B) with a cotton cloth covering; and (C) with a 3-layer mesh disposable covering.