Abstract
BACKGROUND: The comparison of respiratory system compliance (Crs) between COVID and non-COVID ARDS patients has been the object of debate, but few studies have evaluated it when considering applied positive end expiratory pressure (PEEP), which is one of the known determinants of Crs itself. The aim of this study was to compare Crs taking into account the applied PEEP.Entities:
Keywords: Artificial; COVID-19; Intensive care units; PEEP; Respiration; Respiratory system; Respiratory system compliance; Ventilation
Mesh:
Year: 2022 PMID: 35022054 PMCID: PMC8753591 DOI: 10.1186/s12931-022-01930-0
Source DB: PubMed Journal: Respir Res ISSN: 1465-9921
Fig. 1Flowchart of patients included in the study. PEEP positive end expiratory pressure, ARDS acute respiratory distress syndrome
Patient characteristics
| Non-COVID ARDS | COVID ARDS | p value | COVID ARDS, matched cohort | p value* | |
|---|---|---|---|---|---|
| Number of patients | 91 | 276 | 91 | ||
| Age, years | 69 [59, 77] | 68 [60, 73] | 0.30 | 67 [63, 73] | 0.40 |
| Male sex | 61 (67) | 207 (75) | 0.18 | 71 (78) | 0.14 |
| Respiratory rate, breaths·minute−1 | 21 [18, 25] | 22 [20, 25] | 0.16 | 22 [20, 24] | 0.47 |
| PEEP, cmH2O | 8 [6, 10] | 10 [8, 14] | < 0.001 | 10 [8, 12] | < 0.001 |
| pH | 7.34 [7.26, 7.43] | 7.32 [7.23, 7.39] | 0.02 | 7.34 [7.23, 7.39] | 0.13 |
| PaCO2, mmHg | 44 [36, 53] | 51 [44, 62] | < 0.001 | 49 [44, 60] | < 0.001 |
| BMI, kg/m2 | 26 [22, 29] | 28 [26, 32] | < 0.001 | 27 [25, 31] | 0.005 |
| VT, ml·kg IBW | 6.4 [5.8, 7.1] | 6.0 [5.4, 6.5] | < 0.001 | 5.9 [5.4, 6.3] | < 0.001 |
| PaO2/FiO2 | 117 [89, 172] | 103 [77, 138] | 0.017 | 108 [80, 144] | 0.12 |
| Predicted FRC, liters | 3.1 [2.7, 3.6] | 3.1 [2.6, 3.4] | 0.07 | 3.10 [2.7, 3.6] | 0.71 |
| Ventilatory Ratio | 1.7 [1.3, 1.9] | 1.9 [1.5, 2.2] | 0.001 | 1.8 [1.5, 2.1] | 0.027 |
| Best Crs, ml/cmH2O | 38 [29, 50] | 40 [30, 48] | 0.98 | 40 [30, 49] | 0.82 |
| Best minimum PEEP, cmH2O | 6 [4, 8] | 6 [2, 10] | 0.64 | 4 [2, 8] | 0.012 |
Data are shown as median [interquartile range], or count (percentage)
The last column (*) shows the comparison between non-COVID ARDS and COVID ARDS patients matched for predicted FRC. Best compliance is the highest Crs obtained at the tested PEEP levels
Best minimum PEEP is the lowest PEEP level associated with the highest Crs
PEEP positive end expiratory pressure, BMI body mass index, V tidal volume, IBW ideal body weight, FRC functional residual capacity, C respiratory system compliance, ARDS acute respiratory distress syndrome
Fig. 2Crs at different PEEP levels. Linear regression showing Crs at different PEEP levels in non-COVID ARDS and COVID ARDS, in all enrolled patients and in the subset of patients which were matched for predicted FRC. 0 = non-COVID ARDS patients, 1 = COVID ARDS patients. C respiratory system compliance, PEEP positive end expiratory pressure, ARDS acute respiratory distress syndrome, FRC functional residual capacity
Results of the propensity score weighted association between Crs,avg and COVID status at different PEEP levels
| Non-COVID ARDS | COVID ARDS | p value | |
|---|---|---|---|
| Number of patients | 91 | 276 | |
| Crs,avg at PEEP 0 cmH2O | 36 [26, 47] | 33 [25, 42] | 0.002 |
| Crs,avg at PEEP 5 cmH2O | 38 [30, 48] | 37 [28, 44] | 0.10 |
| Crs,avg at PEEP 10 cmH2O | 35 [28, 47] | 36 [29, 44] | 0.27 |
| Crs,avg at PEEP 15 cmH2O | 32 [22, 41] | 32 [24, 40] | 0.13 |
Data are shown as median [interquartile range]
C average respiratory system compliance, PEEP positive end expiratory pressure, ARDS acute respiratory distress syndrome
Fig. 3Distribution of Crs at different PEEP levels. 0 = non-COVID ARDS patients, 1 = COVID ARDS patients. C respiratory system compliance, PEEP positive end expiratory pressure, ARDS acute respiratory distress syndrome, FRC functional residual capacity