| Literature DB >> 35014231 |
Uros Meglic1,2, Oskar Zupanc1,2.
Abstract
BACKGROUND: Identifying the location and scale of radiographic changes in elbow bony impingement (EBI) is critical in formulating an appropriate diagnosis and treatment plan for such patients. The purpose of present study was to evaluate the intra-rater and inter-rater reliability of the new radiographic parameters, Anterior Impingement angle (AIa) and Posterior Impingement angle (PIa), for EBI. In addition, to determine if there was a relationship between radiographic parameters and clinical evaluation. PATIENTS AND METHODS: Three raters of different levels of training evaluated the radiographs of 60 patients (30 in EBI group and 30 in normal group) twice, at least 2 weeks apart. Intra-rater and inter-rater reliabilities were calculated by Intraclass Correlation Coefficients (ICC) with 95% confidence intervals. Correlation between radiographic parameters and clinical evaluation was calculated by Pearson correlation coefficient.Entities:
Keywords: classification; elbow; impingement; osteoarthritis; reliability
Mesh:
Year: 2022 PMID: 35014231 PMCID: PMC8884848 DOI: 10.2478/raon-2021-0056
Source DB: PubMed Journal: Radiol Oncol ISSN: 1318-2099 Impact factor: 2.991
Figure 1Radiographic measurements: (A) Anterior Impingement angle (AIa) and Posterior Impingement angle (PIa) in normal group, (B) AIa and Pia in EBI group, (C) sigmoid notch coverage angle (SNC) in normal group.
Manual and radiographic measurements
| EBI groupa | NORMAL groupa | p | |
|---|---|---|---|
| Flexion (º) | 115 ± 8 | 139 ± 5 | < 0.05 |
| Extension deficit (º) | 19 ± 12 | 0 ± 0 | < 0.05 |
| fROM (º) | 96 ± 14 | 139 ± 5 | < 0.05 |
| SNC (º) | 217 ± 10 | 170 ± 6 | < 0.05 |
| AIa (º) | 44 ± 5 | 20 ± 4 | < 0.05 |
| Pia (º) | 173 ± 10 | 150 ± 5 | < 0.05 |
Mean ± SD;
AIa = Anterior Impingement angle; EBI = elbow bony impingement; SNC = sigmoid notch coverage; PIa = Posterior Impingement angle; fROM = flexion-extension range of motion
Inter-rate r and intra-rater reliabilitiesa
| Inter-rater reliabilitya | Intra-rater reliability for rater 1a | Intra-rater reliability for rater 2a | Intra-rater reliability for rater 3a | ||
|---|---|---|---|---|---|
| EBI group | AIa | 0.85 (0.75–0.94) | 0.87 (0.75–0.94) | 0.87 (0.74–0.94) | 0.87 (0.75–0.95) |
| PIa | 0.84 (0.69–0.92) | 0.83 (0.66–0.91) | 0.88 (0.76–0.94) | 0.85 (0.75–0.93) | |
| NORMAL | AIa | 0.87 (0.76–0.94) | 0.90 (0.81–0.95) | 0.87 (0.74–0.94) | 0.87 (0.75–0.95) |
| group | PIa | 0.85 (0.75–0.93) | 0.86 (0.73–0.93) | 0.86 (0.73–0.93) | 0.86 (0.74–0.94) |
ICC value (95% CI);
AIa = Anterior Impingement angle; CI = confidence interval; EBI = elbow bony impingement; ICC = intraclass correlation coefficients; PIa = Posterior Impingement angle
Inter-rater reliability between two upper-hand expert surgeons and one resident
| Surgeon 1 | Surgeon 1 | Surgeon 2 | ||
|---|---|---|---|---|
| EBI group | AIa | 0.85 (0.71–0.93) | 0.85 (0.74–0.94) | 0.86 (078–0.95) |
| PIa | 0.84 (0.69–0.92) | 0.89 (0.79–0.95) | 0.87 (0.74–0.94) | |
| NORMAL | AIa | 0.87 (0.74–0.94) | 0.90 (0.80–0.95) | 0.88 (0.77–0.94) |
| group | PIa | 0.85 (0.71–0.93) | 0.89 (0.77–0.94) | 0.87 (0.760–0.94) |
ICC value (95% CI);
AIa = Anterior Impingement angle; CI = confidence interval; EBI = elbow bony impingement; ICC = intraclass correlation coefficients; PIa = Posterior Impingement angle
Figure 2Manual flexion-extension range of motion (fROM) and radiographic measurement correlations between (A) f lexion and Anterior Impingement angle AIa, (B) extension deficit and Posterior Impingement angle (Pia).