Abstract
PURPOSE: Spinal dural arteriovenous fistulas (SDAVFs) represent the most common indication for a spinal angiography. The diagnostic reference level (DRL) for this specific endovascular procedure is still to be determined. This single-center study provides detailed dosimetrics of diagnostic spinal angiography performed in patients with SDAVFs.Entities:
Keywords: Diagnostic; Dose reduction; Endovascular; Neurointervention; Reference level
Mesh:
Year: 2022 PMID: 34994809 PMCID: PMC9424156 DOI: 10.1007/s00062-021-01130-1
Source DB: PubMed Journal: Clin Neuroradiol ISSN: 1869-1439 Impact factor: 3.156
Patient demographics and procedural data
| Patient data | |
|---|---|
| Mean age, years (range) | 65 (45–82) |
| 6/25 (24%) | |
| 62 | |
| Preoperative | 30 |
| Postoperative | 32 |
| 22/25 (88%) | |
| 4/25 (16%) | |
| 17/25 (68%) | |
| 16/25 (64%) | |
| 1/62 (1.6%) | |
DSA digital subtraction angiography, Th thoracic, L lumbar, ceMRA contrast-enhanced magnetic resonance angiography
Dosimetric data from spinal angiographies
| All angiographies ( | Preoperative angiographies ( | Postoperative angiographies ( | |
|---|---|---|---|
| Mean DAP, Gy cm2 (range) | 259.9 ± 360 (8.7–1724.2) | 427.83 ± 428.02 (563.5–1724.2) | 97.60 ± 106.17 (8.7–538.7) |
| Median DAP, Gy cm2 | 126 | 256.46 | 62.01 |
| Mean FT, min (range) | 19.6 ± 17.4 (1.8–111.5) | 33.1 ± 23.5 (6.3–111.5) | 11.1 ± 8.2 (1.8–38.8) |
| Median FT, min | 16.9 | 24.2 | 7.6 |
| Mean CV, ml (range) | 142.9 ± 87.6 (40–500) | 232 ± 123.2 (80–500) | 96 ± 51.5 (40–270) |
| Median CV, ml | 120 | 200 | 80 |
| Mean number of DSA runs | 16.6 | 26.3 | 7 |
| Median number of DSA runs | 10 | 20 | 6 |
DAP dose area product, FT fluoroscopy time, CV contrast material volume, DSA digital subtraction angiography
Fig. 1Scatter plot with linear regression lines reporting dose area product (DAP) values of preoperative (pre) (dotted line) and postoperative (post) (solid line) angiographies for each patient. The x-axis represents all patients from number 1 to number 25
Fig. 2Scatter plot with linear regression lines reporting fluoroscopy times (FT) of preoperative (pre) (dotted line) and postoperative (post) (solid line) angiographies for each patient. The x-axis represents all patients from number 1 to number 25
Percentile values of dose area product (DAP) for preoperative and postoperative spinal angiographies. The 75th percentile defines the diagnostic reference level
| Total DAP, Gy cm2 | Preoperative ( | Postoperative ( | All ( |
|---|---|---|---|
| 25th percentile | 121.65 | 42.04 | 57.13 |
| Median | 223.14 | 66.52 | 126 |
| 75th percentile |