Literature DB >> 34993098

Quantification of brown adipose tissue in vivo using synthetic magnetic resonance imaging: an experimental study with mice model.

Mengjuan Huo1,2, Junzhao Ye3, Zhi Dong1, Huasong Cai1, Meng Wang1, Guoping Yin4, Long Qian5, Zi-Ping Li1, Bihui Zhong3, Shi-Ting Feng1.   

Abstract

BACKGROUND: The white adipose tissue (WAT) and brown adipose tissue (BAT) are associated with the development of several obesity-associated disorders. The use of imaging techniques to differentiate BAT from WAT and quantify BAT volume remains challenging, due to limitations such as spatial resolution and magnetic field inhomogeneity. This study aimed to investigate the feasibility for differentiating BAT from WAT, and quantify the BAT volume in vivo using synthetic magnetic resonance imaging (MRI).
METHODS: A total of 16 C57BL/6 mice were scanned using synthetic MRI. Quantitative longitudinal relaxation time (T1) and transverse relaxation time (T2) maps were obtained from the original synthetic MRI data using the synthetic MRI software offline. The T1 and T2 values of interscapular BAT (IBAT) and dorsal subcutaneous WAT were measured. The IBAT volume was calculated using synthetic MRI-derived T2-weighted images (T2WIs) based on its morphological characteristics and quantitative tissue values. The body weight of mice was measured, and the IBAT specimens were excised and weighted. The correlation between IBAT volume and the weight of IBAT gross specimen and between IBAT volume and mouse body weight was analyzed.
RESULTS: The T1 values of BAT (330.3±19.57 ms) were higher than those of WAT (304.42±4.14 ms) (P<0.001), whereas the T2 values of BAT (66.06±5.06 ms) were lower than those of WAT (88.23±7.68 ms) (P<0.001). The area under the curve (AUC) values of the T1 and T2 for differentiating BAT from WAT was 0.942 and 0.995, respectively. The AUC of the T2 values was higher than that of T1 (P=0.04) using the DeLong test. The optimal cut-off value for T2 was 76 ms for differentiating BAT from WAT (100% sensitivity, 93.7% specificity). A moderate correlation was observed between IBAT volume and the weight of the IBAT gross specimen (r=0.662, P=0.014), and between IBAT volume and mouse body weight (r=0.653, P=0.016).
CONCLUSIONS: The quantitative parameters derived using synthetic MRI may be used to detect and differentiate BAT from WAT in vivo. Synthetic MRI may help quantify BAT volume in vivo. 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Brown adipose tissue (BAT); longitudinal relaxation time (T1); synthetic magnetic resonance imaging (MRI); transverse relaxation time (T2); white adipose tissue (WAT)

Year:  2022        PMID: 34993098      PMCID: PMC8666771          DOI: 10.21037/qims-20-1344

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  46 in total

Review 1.  Synthetic Brain MRI: Review of Current Concepts and Future Directions.

Authors:  Fabrício Guimarães Gonçalves; Suraj D Serai; Giulio Zuccoli
Journal:  Top Magn Reson Imaging       Date:  2018-12

2.  Practical T2 quantitation for clinical applications.

Authors:  C S Poon; R M Henkelman
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813

3.  Multimodal imaging approach to monitor browning of adipose tissue in vivo.

Authors:  Xin Hui Derryn Chan; Ghayathri Balasundaram; Amalina Binte Ebrahim Attia; Julian L Goggi; Boominathan Ramasamy; Weiping Han; Malini Olivo; Shigeki Sugii
Journal:  J Lipid Res       Date:  2018-04-13       Impact factor: 5.922

4.  Nanofluidity of fatty acid hydrocarbon chains as monitored by benchtop time-domain nuclear magnetic resonance.

Authors:  Michelle D Robinson; David P Cistola
Journal:  Biochemistry       Date:  2014-11-26       Impact factor: 3.162

5.  Differentiating brown and white adipose tissues by high-resolution diffusion NMR spectroscopy.

Authors:  Sanjay Kumar Verma; Kaz Nagashima; Jadegoud Yaligar; Navin Michael; Swee Shean Lee; Tian Xianfeng; Venkatesh Gopalan; Suresh Anand Sadananthan; Rengaraj Anantharaj; S Sendhil Velan
Journal:  J Lipid Res       Date:  2016-11-14       Impact factor: 5.922

6.  T1 Shortening in the Globus Pallidus after Multiple Administrations of Gadobutrol: Assessment with a Multidynamic Multiecho Sequence.

Authors:  Koung Mi Kang; Seung Hong Choi; Moonjung Hwang; Tae Jin Yun; Ji-Hoon Kim; Chul-Ho Sohn
Journal:  Radiology       Date:  2017-11-01       Impact factor: 11.105

Review 7.  Preclinical In vivo Imaging for Fat Tissue Identification, Quantification, and Functional Characterization.

Authors:  Pasquina Marzola; Federico Boschi; Francesco Moneta; Andrea Sbarbati; Carlo Zancanaro
Journal:  Front Pharmacol       Date:  2016-09-26       Impact factor: 5.810

8.  Targeted Molecular Magnetic Resonance Imaging Detects Brown Adipose Tissue with Ultrasmall Superparamagnetic Iron Oxide.

Authors:  Qingqiao Hu; Xiangxun Chen; Juan Liu; Wenjuan Di; Shan Lv; Lijun Tang; Guoxian Ding
Journal:  Biomed Res Int       Date:  2018-10-10       Impact factor: 3.411

9.  Quantitative T2 Mapping of Knee Cartilage: Comparison between the Synthetic MR Imaging and the CPMG Sequence.

Authors:  Seung Hyun Lee; Young Han Lee; Ho-Taek Song; Jin-Suck Suh
Journal:  Magn Reson Med Sci       Date:  2018-02-01       Impact factor: 2.471

10.  Application of Synthetic MRI for Direct Measurement of Magnetic Resonance Relaxation Time and Tumor Volume at Multiple Time Points after Contrast Administration: Preliminary Results in Patients with Brain Metastasis.

Authors:  Koung Mi Kang; Seung Hong Choi; Moonjung Hwang; Roh-Eul Yoo; Tae Jin Yun; Ji-Hoon Kim; Chul-Ho Sohn
Journal:  Korean J Radiol       Date:  2018-06-14       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.