Literature DB >> 34989873

Continuous background correction of refractive index signal to improve monoclonal antibody concentration monitoring during UF/DF and SPTFF operations.

Thaddaeus A Webster1, Kelley Turner2, Caitlin DuBois2, Ryan MacDougall2, Carrie Mason2.   

Abstract

Inline refractive index (RI) has the potential for monitoring protein concentration during final bulk concentration. While useful for monitoring and controlling product concentration, RI is sensitive to the respective background buffer being used for processing. This raises concerns around variations in buffer preparations, and during diafiltration where the buffer background is a mixture of different buffers during exchange. This study evaluated whether the use of a RI probe in the permeate line could facilitate continuous background subtraction (dual RI) and improve concentration monitoring during ultrafiltration/diafiltration and single pass TFF concentration for IgG1 and IgG4 antibodies. The proposed dual RI strategy yielded reductions in % error compared to the use of a single refractive index estimate from the retentate line (6.18% vs 8.63% for IgG4 and 2.65% vs 8.85% for IgG1) during traditional ultrafiltration/diafiltration. The improvement in IgG estimates were best during diafiltration where the continuous background subtraction of the permeate RI-enabled continuous monitoring of antibody material without knowledge of what the background buffer was compared to the use of a single RI estimate (6.47% vs 10.79% for IgG4 and 3.29% vs 19.59% for IgG1). In contrast minimal improvement to accuracy was obtained when using SPTFF as a concentration step. The ability to monitor product concentration changes via the proposed dual RI approach removes the need for complex calibrations, minimal worry about changing buffer backgrounds during diafiltration, and could enable better process control during product concentration in the cGMP manufacture of biologics.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Continuous product concentration monitoring; Dual RI

Mesh:

Substances:

Year:  2022        PMID: 34989873     DOI: 10.1007/s00449-021-02683-8

Source DB:  PubMed          Journal:  Bioprocess Biosyst Eng        ISSN: 1615-7591            Impact factor:   3.210


  7 in total

1.  Refractive index of proteins in aqueous sodium chloride.

Authors:  J Wen; T Arakawa
Journal:  Anal Biochem       Date:  2000-05-01       Impact factor: 3.365

Review 2.  Recovery and purification process development for monoclonal antibody production.

Authors:  Hui F Liu; Junfen Ma; Charles Winter; Robert Bayer
Journal:  MAbs       Date:  2010-09-01       Impact factor: 5.857

3.  The specific refractive increment of some purified proteins.

Authors:  G E PERLMANN; L G LONGSWORTH
Journal:  J Am Chem Soc       Date:  1948-08       Impact factor: 15.419

Review 4.  Size-exclusion chromatography with on-line light-scattering, absorbance, and refractive index detectors for studying proteins and their interactions.

Authors:  J Wen; T Arakawa; J S Philo
Journal:  Anal Biochem       Date:  1996-09-05       Impact factor: 3.365

5.  On the distribution of protein refractive index increments.

Authors:  Huaying Zhao; Patrick H Brown; Peter Schuck
Journal:  Biophys J       Date:  2011-05-04       Impact factor: 4.033

6.  Multi-attribute PAT for UF/DF of Proteins-Monitoring Concentration, particle sizes, and Buffer Exchange.

Authors:  Laura Rolinger; Matthias Rüdt; Juliane Diehm; Jessica Chow-Hubbertz; Martin Heitmann; Stefan Schleper; Jürgen Hubbuch
Journal:  Anal Bioanal Chem       Date:  2020-02-18       Impact factor: 4.142

7.  Determination of protein absorption coefficients using a refractive index chromatographic monitor.

Authors:  N M Young
Journal:  J Biochem Biophys Methods       Date:  1985-03
  7 in total