Evianne Kruithof1, Sina Amirrajab1, Kevin D Lau2, Marcel Breeuwer1,3.
Abstract
The late enhanced magnetic resonance image dataset in this article is simulated using a mechanistic cardiac phantom that includes an myocardial infarct. Settings of the image simulation pipeline are adjusted such that high- and low-resolution images, with and without slice alignment artifacts, are simulated. Our article on the influence of image artifacts on image-based models of the cardiac electrophysiology is based on this data (Kruithof et al., 2021). This dataset provides image-analysis researchers a reference to perform validation of their methods using the included high-resolution ground truth image, a resource that is often unavailable clinically.Entities:
Keywords: Ground truth magnetic resonance imaging data; Image artifacts; Image resolution; Slice misalignment; Ventricular tachycardia
Year: 2021 PMID: 34984215 PMCID: PMC8693344 DOI: 10.1016/j.dib.2021.107691
Source DB: PubMed Journal: Data Brief ISSN: 2352-3409
Fig. 1(A) Short axis view and (B) long axis view of the high-resolution ground truth image1. Long axis view of the (C) low-resolution image2 and (D) low-resolution image3 including slice alignement artifacts. Figure from Kruithof et al. [1].
Fig. 2Designed infarct geometry for the XCAT heart phantom. The scar core is visualized in red, the outer border zone and border zone channel in yellow. Figure from Kruithof et al. [1].
| Subject | Cardiology and Cardiovascular Medicine |
| Specific subject area | Postinfarction cardiac imaging |
| Type of data | Image |
| How data were acquired | The data was simulated utilizing the mechanistic 4D eXtended CArdiac Torso (XCAT) heart phantom (Segars et al., 2010), Rhinoceros modelling software 6 (Rhino, 2020) and the openGTN MRI simulation pipeline (openGTN, 2020). |
| Data format | Raw |
| Parameters for data collection | Simulated data is generated using a virtual cardiac phantom containing a myocardial infarct. Mechanistic breathing parameters are adjusted to create late enhanced MR images with and without slice alignment artifacts. Multiple data simulations are performed to provide both high- and low-resolution images as well. |
| Description of data collection | The mechanistic 4D XCAT non-infarcted heart model is utilized as anatomical phantom and extended with a myocardial infarct scar. Bloch-equation based MR image simulation is performed using the simulation pipeline of openGTN et al., 2020 . |
| Data source location | Institution: Eindhoven University of Technology |
| Data accessibility | |
| Related research article | E. Kruithof, S. Amirrajab, M.J.M. Cluitmans, K.D. Lau, M. Breeuwer, Influence of Image Artifacts on Image-Based Computer Simulations of the Cardiac Electrophysiology, Computers in Biology and Medicine (Kruithof et al., 2021). |