Literature DB >> 34977726

Geometric characteristics of bicuspid aortic valves.

Jan Nijs1,2, Babs Vangelder3, Kaoru Tanaka2,4, Sandro Gelsomino1,5, Ines Van Loo1, Mark La Meir1,5, Jos Maessen5,6, Bas L J H Kietselaer7.   

Abstract

OBJECTIVE: We studied the coaptation angles α and β in bicuspid aortic valve geometry from computed tomography scan images.
METHODS: In 45 patients, we calculated the coaptation angle α (the angle between the nonfused commissures crossing the center of coaptation), angle β (between the nonfused commissures crossing the center of the reference circle), angles γ1 and γ2 and ε1 and ε2 (angle between the nonfused commissures and the coaptation point at the raphe or the perfect midpoint, respectively), the length of the raphe, the absolute and relative sinuses' surfaces (relative to the perfect circle and the percentage exceeding the ideal circle). Spearman correlation was employed to investigate the associations among all parameters.
RESULTS: The coaptation angles α and β were significantly different (P < .001). We found a significant correlation of α with the length of the raphe (P = .008), whereas β was dependent on the position of the commissures. Both γ1 and γ2 (P = .04), or ε1 and ε2 (P < .001) significantly differed from each other and ε2 was the most constant angle, although its size geometrically depends on β. The noncoronary was the largest sinus, and β was the primary determinant of its increased size in bicuspid aortic valves with righ/left fusion pattern.
CONCLUSIONS: The coaptation angle α is influenced by the length of the raphe, whereas angle β is dependent on the position of the commissures. The position of the raphe can vary and is not always situated in the middle of the free edge. The position of the right/non commissure is variable, whereas the right/left commissure is more fixed.
© 2021 The Author(s).

Entities:  

Keywords:  BAV, bicuspid aortic valve; CT, computed tomography; NCS, noncoronary sinus; aorta; aortic valve; aortic valve repair; bicuspid

Year:  2021        PMID: 34977726      PMCID: PMC8691778          DOI: 10.1016/j.xjtc.2021.08.032

Source DB:  PubMed          Journal:  JTCVS Tech        ISSN: 2666-2507


Summarization of the main features of the article. In BAV with complete fusion, the commissural orientation is determined by a variable combination of commissural position and length of the raphe. The coaptation angle α, influenced by the length of the raphe, does not reflect the correct position of the commissures dictated by the commissural angle β. For repair, preferably both angles should be considered separately. The orientation of the raphe and position of R/N commissure are variable. The noncoronary sinus was the largest that increases with β. See Commentaries on pages 216 and 217. The bicuspid aortic valve (BAV) is the most common congenital cardiac malformation, affecting approximately 1% to 2% of the general population,1, 2, 3, 4, 5, 6 Its main anatomic feature is the consequence of anomalous embryologic development resulting in 2 functional commissures of normal height (bicommissural valve) with a third rudimentary commissure varying in height and present in approximately 95% of cases. BAV affects the aortic root, ascending aorta, or aortic arch in about 70% of patients, and it is among the most common causes of aortic stenosis, aortic dilatation,,, and aortic regurgitation,, frequently requiring surgical intervention.9, 10, 11 Moreover, because BAV often affects individuals in their third and fourth decades of life, operative decision making is challenging in these patients and the appropriate choice among the alternative possibilities of treatment is still an area of concern and debate., During the past decade, interest in aortic valve repair has increased,,, as has knowledge that a detailed understanding of the morphology and function of the BAV are necessary to obtain a successful and durable repair. Because the BAV morphology is complex, anatomical variations often occur that have not been completely analyzed. It is, therefore, necessary to have an even more in-depth insight into BAV structures. Although a commissural orientation (coaptation angle α) >150° obtained through repositioning of the nonfused commissures has been advocated to increase the durability of the surgical repair, we hypothesize that the relationship between the coaptation angle and the position of the nonfused commissures is not constant. This study describes a new methodology for examining the BAV geometrical characteristics and is aimed at investigating the relation between the exact position of the commissures and the coaptation angle α, discussing their potential influence on surgical valve repair.

Methods

Due to the retrospective nature of the study, ethical committee approval was waived for. The patients gave their written consent to the intervention and, at the same time, their approval the use of data for scientific purposes.

Patients

Consecutive patients with a diagnosed BAV undergoing a cardiac computed tomography (CT) or a preoperative CT of the thoracic aorta between 2008 and 2015 were included in the study. All cardiac CT imaging procedures where electrocardiography-triggered. Reasons for exclusion were significant motion artifacts.

CT Examination and Measurements

All patients underwent cardiac CT studies or CT scans of the thoracic aorta. Triggered diastolic images were taken at 75% of the RR-interval on average. Raw data were used for the analysis. All CT scans were searched for the ideal image plane, clearly showing the aortic valve cusps, their free margins, the raphe, and the nonfused commissures. Optimal diastolic images without motion artifacts were selected manually. Geometrical parameters were measured in diastolic images. For this purpose, 2 different commercially available software systems were used: IMPAX (Agfa, Mortsel, Belgium), IntelliSpace (Philips, Eindhoven, the Netherlands) and Syngo Via (Siemens, Erlangen, Germany). The same observer performed all CT measurements 2 times. Figure E1 describes the methodology to create the desired image plane. Geometrical parameters were used to analyze the asymmetric morphology in BAVs employing GeoGebra software (https://www.geogebra.org).
Figure E1

Description of the steps to create the desired image plane. Panel A: Step1: Multiplanar images in sagittal, coronal, and axial orientation are created to be simultaneously viewed to obtain the correct level in the axial orientation. Panel B: Step2: The sagittal and coronal images are rotated in the direction indicated by the arrows to obtain the right image plane of the aortic valve. The red reference line in the sagittal image is first used to rotate the view. This line approximates the level of the aortic annulus (orange dotted line). Panel C: Step 3: The procedure is repeated in the coronal image. Then, the computed tomography crosshair is moved upward, in cranial direction, to the level of maximal aortic sinus dimensions (in accordance to the orange arrow). These modifications also change the former coronal and axial images as displayed in sequence I. Panel D: Step 4: The axial image is checked to evaluate as whether this view corresponds with the clearest plane of the aortic valve. This control image is displayed in Panel D.

The following geometric parameters were measured: The length of the raphe (Figure 1, A and B).
Figure 1

Schematic of raphe and sinus measurements from computed tomography scan. A and B, Measurement of the length of the raphe. The length of the raphe |AD| was measured as the distance between from the external point of the raphe A and the coaptation midpoint D. C and D, Sinuses' surface. Three segments were drawn: the length of the raphe |AD| as described above; a line between the nonfused commissure B, and the coaptation midpoint D (segment |AD|); and A line between the nonfused commissure A and the coaptation midpoint D, segment |BD|). These 3 lines defines the extension of the three sinuses (noncoronary [NC], right coronary [RC], and left coronary [LC]). Once the sinuses were defined, their surfaces were measured. E and F, Relative sinuses' surface. For these measurements, a circle was drawn passing through the position of the raphe A, the position of the non-fused commissure B, and the position of the nonfused commissure C, and its center E was identified. Three fixed points were placed at the level of maximum sinus dimensions (points J, G, and H, respectively). Then another series of 3 fixed points were placed on the created circle, respectively named I, K, and L. The distance |GK| was the difference (protrusion) between the midpoint of the RC sinus and its projection on the created circle. Similarly, the segment |HL| was the difference between the midpoint of the LC sinus and its projection on the created circle and the distance |IJ| was the difference between the midpoint of the NC sinus and its projection on the created circle. These distances were measured as the differences between the distances from single sinuses midpoints (G, H, and J for the RC, LC and NC, respectively) and the circle center E and the distances from single sinus midpoint projection on the circle (K, L, and I for the RC, LC, and NC, respectively). Finally, the amount of sinus protrusion was calculated as the ratio between these distances. For the RC it was: |GK|/(|GK| + |KE|) = |GK|/GE. Similarly, the protrusion of LC was calculated as: |HL|/(|HL| + |LE| = |HL|/HE and the protrusion of NC was calculated as: IJ|/(|IJ| + |JE|) = |IJ|/IE, for the LC and NC, respectively.

The absolute sinus surfaces (Figure 1, C and D) to evaluate the morphological trend of sinuses within the bicuspid asymmetry. This enabled us to determine the contribution of each sinus to the total aortic sinus surface and to assess their correlation with other parameters. Relative sinus surface, which is the corresponding surface compared with a reference circle with a fixed radius and center E (Figure 1, E and F) and was given as a percentage of each sinus exceeding the reference circle. Three fixed points were placed at the level of maximum sinus dimensions (points J, G, and H). Then another series of three fixed points were placed on the created circle on the corresponding lines toward J, G, and H, respectively named I, K, and L. The distance |GK|, |HL|, and |IJ| were measured. The other 3 lines were drawn between I, K, and L and the center of the circle E (segments |IE|, |KE|, and |LE|), and the sections were measured. The left relative sinus was obtained as | HL|/HE. Similarly, the relative surfaces of the other sinuses were calculated as | GK|/GE and |IJ|/IE, for the right and noncoronary sinsues (NCS), respectively. The coaptation angle α,: The angle between 2 lines drawn from nonfused commissures to the coaptation midpoint (Figure 2, A and B).
Figure 2

Schematic of angles' measurements from the computed tomography scan. A and B, Coaptation angle α, which is the angle between the nonfused commissures |BD| and |DC| from the bicuspid coaptation midpoint D. C and D, A circle was drawn through the position of the raphe A, the position of the nonfused commissure B, and the position of the nonfused commissure C and its center E was identified. Angle β is defined as the angle between the nonfused commissures |BE| and |DE| and center of the circle E. It represents the true commissural orientation in an ideal circle. E and F, The point E is the center of a circle drawn through the position of the raphe A, the position of the nonfused commissure B, and the position of the nonfused commissure C, whereas D is the coaptation point. The distance between these 2 central points |ED| was measured. In addition, 2 lines were drawn from the position of the raphe A to both center points E (line |AE|) and D (line |AD|) and were measured. Their difference in distance (|AE| – |AD|) was also determined and angle γ (red) between EAD was calculated. Two more angles were measured: the angle γ1 (light blue) was the angle between the nonfused commissure B, the position of the raphe A, and the coaptation point D, obtained drawing the segments |BD| and |AD|; the angle γ2 (light green) was the angle between the nonfused commissure and the position of the raphe A, obtained drawing the segments |CD| and |AD|. G and H, Reference angles. The point E is the center of a circle drawn through the position of the raphe A, the position of the nonfused commissure B and the position of the nonfused commissure C. Another 2 angles were measured: the angle ε1 (light blue) was the angle between the nonfused commissure B, the position of the raphe A, and the circle center E, obtained drawing the segments |BE| and |AE|; the angle ε2 (light green) was the angle between the nonfused commissure and the position of the raphe A, obtained drawing the segments |CE| and |AE|. To confirm the hypothesis of a rather constant position of the commissures between the right and the left cusp, and the left and the noncoronary cusp, ε2 should be a constant. NC, Noncoronary.

The angle β: The angle between 2 lines drawn from 1 nonfused commissure and the center point of the perfect circle created (Figure 2, C and D). The angle γ: The angle between the raphe, and a line drawn between the commissures and the perfect midpoint (Figure 2, E and F). Angles γ1 and γ2 were comprised between each of the nonfused commissures and the raphe toward the coaptation midpoint. Angles ε1 and ε2 (Figure 2, G and H): The angles between lines drawn from nonfused commissures on 1 hand and fused commissure on the other hand toward the perfect midpoint. Together with β, they were used to determine position consistency between commissures. To confirm the hypothesis of the fixed position of the commissures between the right and the left cusp, and the left and the noncoronary cusp, ε2 should be a constant. Aortic dimensions. Aortic annulus, aortic root, sinotubular junction, ascending aorta, and the aortic arch were measured. The aortic annulus was determined following the Society of Cardiovascular Computed Tomography guidelines.15, 16 Figure E2 shows the method used in the case of the BAV with only 2 sinuses.
Figure E2

Method used in case of bicuspid aortic valve (BAV) with only 2 sinuses. Panel A: Upper Left, Fixed points are placed on the insertions of the non-fused commissures (B, C) and the central coaptation point (D). These valves contain no raphe, so only 2 points B and C can be used for creating a circle. Following geometrical rules, a circle cannot be created with only 2 points. Therefore, 2 opposite half circles are drawn through B and C, creating 1 circle (upper middle). The central point E was determined. The 2 circles are overlapped (upper right). Panel B: Angle α (BCD) and β (BED) are measured. The other angles are measured as for 3-sinus valves. Panel C: Measurement of relative aortic sinus dimensions: the 2 sinuses are indicated with arches. Fixed points are placed at the level of maximum sinus dimensions (points G and H). Then another series of fixed points are placed across from G and H, on the reference circle, respectively named I and F. From the center point E line sections are being drawn extending to G and H. These distance lines are determined. Then a next series of section lines are drawn from the same midpoint E to the opposite points I and also these distances are measured. These different dimensions are used to analyze relative to one another. The mathematical variations between the midpoints D and E are determined the same as applied in 3-sinus-valves using point A shown in the figure.

Schematic of raphe and sinus measurements from computed tomography scan. A and B, Measurement of the length of the raphe. The length of the raphe |AD| was measured as the distance between from the external point of the raphe A and the coaptation midpoint D. C and D, Sinuses' surface. Three segments were drawn: the length of the raphe |AD| as described above; a line between the nonfused commissure B, and the coaptation midpoint D (segment |AD|); and A line between the nonfused commissure A and the coaptation midpoint D, segment |BD|). These 3 lines defines the extension of the three sinuses (noncoronary [NC], right coronary [RC], and left coronary [LC]). Once the sinuses were defined, their surfaces were measured. E and F, Relative sinuses' surface. For these measurements, a circle was drawn passing through the position of the raphe A, the position of the non-fused commissure B, and the position of the nonfused commissure C, and its center E was identified. Three fixed points were placed at the level of maximum sinus dimensions (points J, G, and H, respectively). Then another series of 3 fixed points were placed on the created circle, respectively named I, K, and L. The distance |GK| was the difference (protrusion) between the midpoint of the RC sinus and its projection on the created circle. Similarly, the segment |HL| was the difference between the midpoint of the LC sinus and its projection on the created circle and the distance |IJ| was the difference between the midpoint of the NC sinus and its projection on the created circle. These distances were measured as the differences between the distances from single sinuses midpoints (G, H, and J for the RC, LC and NC, respectively) and the circle center E and the distances from single sinus midpoint projection on the circle (K, L, and I for the RC, LC, and NC, respectively). Finally, the amount of sinus protrusion was calculated as the ratio between these distances. For the RC it was: |GK|/(|GK| + |KE|) = |GK|/GE. Similarly, the protrusion of LC was calculated as: |HL|/(|HL| + |LE| = |HL|/HE and the protrusion of NC was calculated as: IJ|/(|IJ| + |JE|) = |IJ|/IE, for the LC and NC, respectively. Schematic of angles' measurements from the computed tomography scan. A and B, Coaptation angle α, which is the angle between the nonfused commissures |BD| and |DC| from the bicuspid coaptation midpoint D. C and D, A circle was drawn through the position of the raphe A, the position of the nonfused commissure B, and the position of the nonfused commissure C and its center E was identified. Angle β is defined as the angle between the nonfused commissures |BE| and |DE| and center of the circle E. It represents the true commissural orientation in an ideal circle. E and F, The point E is the center of a circle drawn through the position of the raphe A, the position of the nonfused commissure B, and the position of the nonfused commissure C, whereas D is the coaptation point. The distance between these 2 central points |ED| was measured. In addition, 2 lines were drawn from the position of the raphe A to both center points E (line |AE|) and D (line |AD|) and were measured. Their difference in distance (|AE| – |AD|) was also determined and angle γ (red) between EAD was calculated. Two more angles were measured: the angle γ1 (light blue) was the angle between the nonfused commissure B, the position of the raphe A, and the coaptation point D, obtained drawing the segments |BD| and |AD|; the angle γ2 (light green) was the angle between the nonfused commissure and the position of the raphe A, obtained drawing the segments |CD| and |AD|. G and H, Reference angles. The point E is the center of a circle drawn through the position of the raphe A, the position of the nonfused commissure B and the position of the nonfused commissure C. Another 2 angles were measured: the angle ε1 (light blue) was the angle between the nonfused commissure B, the position of the raphe A, and the circle center E, obtained drawing the segments |BE| and |AE|; the angle ε2 (light green) was the angle between the nonfused commissure and the position of the raphe A, obtained drawing the segments |CE| and |AE|. To confirm the hypothesis of a rather constant position of the commissures between the right and the left cusp, and the left and the noncoronary cusp, ε2 should be a constant. NC, Noncoronary.

Data Analysis

The distribution of continuous variables was defined by using the Shapiro-Wilk test. According to the results of the test, continuous data were expressed as median ± interquartile range difference. Comparisons were carried out by the Wilcoxon signed-ranked test, Mann-Whitney U test, and Kruskal-Wallis test. Spearman rho was employed to investigate bivariate correlations between various continuous parameters. Intrarater reliability was analyzed by calculating intraclass correlations and applying the Bland-Altman plot, as shown in Figure E3 and E4. SPSS software version 22.0 (IBM-SPSS, Inc, Chicago, Ill) was used for all calculations.
Figure E3

Bland-Altman plots and intrarater reliability. The y-axis illustrates the difference (DIFF) between the 2 measurements. The x-axis shows the means between the 2 repeated measurements.

Figure E4

Bland-Altman plots and intrarater reliability. The y-axis illustrates the difference (DIFF) between the 2 measurements. The x-axis shows the means between the 2 repeated measurements. L, Left coronary; R, right coronary; NC, noncoronary.

Results

Patient Population

The study population consisted of 45 patients. Baseline patient characteristics are shown in Table 1. All patients had congenital BAV, of which 35 (77.8%) had an right/left fusion pattern. The most prevalent aortic pathology was a supracoronary ascending aortic aneurysm (n = 27 [60%]). The aorta was unaffected in 13% (n = 6).
Table 1

Patient characteristics (N = 45)

CharacteristicResult
Age (y)56
Male sex38 (84.4)
BMI26
Hypertension24 (53.3)
Hypercholesterolemia17 (37.8)
Diabetes mellitus3 (6.7)
Coronary artery disease8 (17.8)
Chronic renal failure1 (2.2)
Familial BAV1 (2.2)
Marfan syndrome0
Genetic testing9 (20)
Cusp fusion pattern
 True bicuspid4 (8.9)
 Right/left fusion pattern35 (77.8)
 Right/non fusion pattern5 (11.1)
 Left/non fusion pattern1 (2.2)
Aortic pathology
 None6 (13.3)
 Ascending aortic aneurism27 (60)
 Aortic coarctation2 (4.4)
 Aortic root aneurysm5 (11.1)
 Combined aneurysm4 (8.9)
 Type A dissection1 (2.2)
Aortic valve surgery
 None23 (51.1)
 Repair11 (24.4)
 Replacement11 (24.4)
Aortic surgical correction
 None29 (64.4)
 David3 (6.7)
 Yacoub7 (15.6)
 Perceval2 (4.4)
Combined surgery
 Bentall4 (8.9)
Surgical indication
 None26 (57.8)
 Aortic regurgitation2 (4.4)
 Aneurysm progression6 (13.3)
 Aortic stenosis6 (13.3)
 Aortic regurgitation + aneurysm progression4 (8.9)
 Dissection1 (2.2)
LVEF (%)60 (7)
LVEDD (mm)51.5 (11.75)
Annulus diameter (mm)28 (5)
Sinus diameter (mm)40.75 (10.88)
Ascending aorta diameter (mm)42 (10.75)
Aortic regurgitation grade
 None10 (22.2)
 Mild22 (48.9)
 Moderate6 (13.3)
 Serious4 (8.9)
Aortic regurgitation type
 Unknown19 (42.2)
 Type 1 (dilatation)12 (26.7)
 Type 2 (prolapse)4 (8.9)
 Type 3 (restriction)7 (15.6)
Maximum gradient (mm Hg)25 (32.42)
Mean gradient (mm Hg)15.75 (20.6)
TEE5 (11)

Values are presented as median (interquartile range difference) or as n (%). BMI, Body mass index; BAV, biscuspid aortic valve; LVEF, left ventricle ejection fraction; LVEDD, left ventricular end diastolic diameter; TEE, transesophageal echocardiography.

Patient characteristics (N = 45) Values are presented as median (interquartile range difference) or as n (%). BMI, Body mass index; BAV, biscuspid aortic valve; LVEF, left ventricle ejection fraction; LVEDD, left ventricular end diastolic diameter; TEE, transesophageal echocardiography.

General CT Features

CT imaging characteristics are shown in Table 2. In 53.3% of patients, a calcified aortic valve was found. 91.1% of the valves consisted of 3 sinuses, of which the NCS was the largest. Seventy-seven percent of patients had normal anatomy of the aortic arch. One patient was diagnosed with a bovine arch, in 1 other patient an aberrant right subclavian artery was found. Table E1 shows that excluding the ascending aorta, the aortic dimensions were larger in men than in women. Furthermore, 2-sinus valves showed larger aortic root, sinotubular junction, and ascending aorta diameters. In contrast, aortic dimensions did not significantly vary between valves with different cusp fusion patterns.
Table 2

General computed tomography features (N = 45)

Result
Scan protocol
 Flash38 (84.4)
 Step-and-shoot7 (15.6)
Calcified aortic valve24 (53.3)
Cardiac cycle: % of RR-interval75 [17]
No. of sinuses
 25 (11.1)
 340 (88.9)
Aortic arch anatomy
 Unknown8 (17.8)
 Normal35 (77.8)
 Bovine arch1 (2.2)
 Aberrant right subclavian arteries1 (2.2)
Aorta dimensions (mm)
 Annulus27 (5)
 Aortic root39.5 (10)
 STJ32.5 (8.95)
 Ascending43 (9.75)
 Aortic arch28 (5.75)

Values are presented as median (interquartile range difference) or as n (%). RR-interval, Interbeat interval; STJ, sinotubular junction.

Table E1

Aortic dimensions by subgroups (N = 45) as determine by computed tomography

VariableAorta dimensions (mm)
MenWomen2 sinuses3 sinusesRight/left fusion patternRight/non fusion patternTrue
Annulus27 (3.9)24 (7.0)25 (3.0)27 (4.5)27 (5.0)27 (4.3)25 (2.5)
Aortic root40 (8.7)35 (16.0)45 (13.0)35 (9.8)35 (10.5)40 (11.6)36 (12.0)
STJ34 (9.5)30 (5.8)35 (12.5)32 (7.5)31 (8.8)36 (7.2)35.2 (9.5)
Ascending aorta43 (9.0)41 (13.0)50 (3.5)42 (10.0)43 (10.5)41 (9.5)48 (9.7)
Aortic arch28 (8.0)24.5 (5.5)28 (5.5)28 (5.2)

Values are presented as median (interquartile range difference) or as n (%). STJ, Sinotubular junction.

Significant versus women.

Significant versus 3-sinuses; annulus P = .001; aortic root P = .015; STJ P = .002; ascending aorta P = .255; aortic arch P = .002.

General computed tomography features (N = 45) Values are presented as median (interquartile range difference) or as n (%). RR-interval, Interbeat interval; STJ, sinotubular junction.

Geometrical Measurements

The measured geometric parameters are shown in Table 3. The α and β angles were significantly different (P < .001). The median angle difference was 15°with a maximum difference of 47° and a minimal difference of 1.4°. This difference was significantly higher in the 3-sinus group (P = .009), whereas it was not different between BAV with varying cusp fusion patterns (P = .28). The angles γ1 and γ2 were statistically different (P = .04) and the median commissural orientation ε1 differed from ε2 (P < .001). From all calculated commissural positions, ε2 appeared to be the most constant angle.
Table 3

Cusp geometry (N = 45)

Result
Commissural positions
 α151° (44.6°)
 β144.50° (28.0°)
 γ8.2° (1.5°)
 γ1107.4° (22.3°)
 γ2103.1° (18.2°)
 ε1113.00° (22.0°)
 ε2100.53° (13.3°)
Length of raphe (mm)15.6 (3.95)
|DE| (mm)0.4 (0.1)
Sinus surface (cm2)
 LCS6.8 (4.3)
 RCS6.95 (4.95)
 NCS8.7 (4.57)
Sinus size relative a perfect circle (% increase)
 LCS+13.8 (5.7)
 RCS+10.7 (4.6)
 NCS+16.7 (6.7)

Values are presented as median (interquartile range difference) or as percentage (interquartile range difference). |DE|, Distance between the commissural point and the reference center; LCS, left coronary sinus; RCS, right coronary sinus; NCS, noncoronary sinus.

Cusp geometry (N = 45) Values are presented as median (interquartile range difference) or as percentage (interquartile range difference). |DE|, Distance between the commissural point and the reference center; LCS, left coronary sinus; RCS, right coronary sinus; NCS, noncoronary sinus. Looking at the relative size of each sinus beyond the radius of the reference circle, the NCS appeared to be the largest sinus (+16.7% ± 6.67%). In contrast, the right coronary sinus had the smallest percentages with a median increase of +10.71% ± 4.63% compared with the perfect circle.

Correlation Analysis

A moderate correlation (Table 4) was found between the length of raphe and the angle α (P = .008), whereas there was no correlation with β (P = .548). Moreover, Δαβ significantly correlated with and the distance between the commissural point and the reference center |DE| (P < .001) as well as with Δ |AE||AD| (P < .001). In contrast, both Δγ1 and γ2 showed no correlation with Δαβ. There was a slight inverse correlation between the 3 sinus surfaces and Δαβ (P = .01 and .02 and P = .017, in left coronary sinus, right coronary sinus, and NCS, respectively) and a small direct relationship between the NCS surface and β (P = .03).
Table 4

Correlation analysis

VariableSpearman rhoCorrelation coefficientP value95% confidence interval
Length rapheαβRaphe length0.4120.097−0.112.008.584.4870.119 to 0.6440.211 to 0.381−0.403 to 0.217
Δαβ|AD||AE|Δ |AD||AE||DE|Δγ1γ20.265−0.1520.7130.7150.171.079.319<.001<.001.325−0.095 to 0.554−0.450 to 0.1560.498 to 0.8620.483 to 0.853−0.181 to 0.493
LC sinus surfaceαβΔαβΔγ1γ2Δε1ε2Raphe length0.1180.194−0.3560.036−0.2690.043.438.201.016.837.074.789–0.192 to 0.414−0.099 to 0.486−0.604 to −0.054−0.283 to 0.337−0.555 to 0.011−0.241 to 0.323
RC sinus surfaceαβΔαβΔγ1γ2Δε1ε2Raphe length−0.1160.025−0.3480.0660.0590.010.475.880.028.713.719.953−0.428 to 0.218−0.302 to 0.316−0.595 to −0.032−0.291 to 0.411−0.275 to 0.367−0.282 to 0.308
NC sinus surfaceαβΔαβΔγ1γ2Δε1ε2Raphe length0.1740.321−0.353−0.014−0.1440.063.254.031.017.937.345.697−0.146 to 0.4570.007 to 0.544−0.607 to 0.049−0.297 to 0.290−0.449 to 0.168−0.221 to 0.342

Values are presented as median (interquartile range difference) or as n (%). |AD|, Distances from nonused commissures to the coaptation point; |AE|, distances from nonfused commissures to the perfect central point; |DE|, distance between the commissural point and the reference center; LC, left coronary; RC, right coronary; NC, noncoronary.

Correlation analysis Values are presented as median (interquartile range difference) or as n (%). |AD|, Distances from nonused commissures to the coaptation point; |AE|, distances from nonfused commissures to the perfect central point; |DE|, distance between the commissural point and the reference center; LC, left coronary; RC, right coronary; NC, noncoronary. When analyzing the correlations between the relative sinus sizes and all geometrical parameters (Table 5), we observed that the left sinus surface showed a moderate correlation that was inverse with β (P = .007). At the same time, it was directly correlated to Δαβ (P = .001), Δγ1γ2 (P = .001) Δε1ε2 (P = .01), and |DE| (P < .001). In addition, the right sinus surface significantly inversely correlated with Δαβ (P = .001). Finally, we failed to find any significant correlation between the noncoronary sinus surface and the other parameters.
Table 5

Relative sinus sizes: Correlation analysis

VariableSpearman rhoCorrelation coefficientP value95% confidence interval
LC sinus surfaceαβΔαβΔγ1γ2Δε1ε2Raphe length|DE|−0.266−0.3960.4640.3380.360−0.2610.548.077.007.001.047.015.100<.001−0.578 to 0.102−0.652 to −0.0920.180 to 0.6710.016 to 0.5960.033 to 0.614−0.518 to 0.0470.308 to 0.731
RC sinus surfaceαβΔαβΔγ1γ2Δε1ε2Raphe length|DE|−0.0500.146−0.3920.132−0.1980.273−0.252.742.338.008.449.192.084.094–0.356 to 0.230–0.166 to 0.442−0.632 to −0.108−0.231 to 0.457−0.526 to 0.145−0.073 to 0.556−0.497 to 0.062
NC sinus surfaceαβΔαβΔγ1γ2Δε1ε2Raphe length|DE|−0.007−0.2280.0750.1230.0750.1160.144.964.132.625.483.623.470.346−0.278 to 0.275−0.509 to 0.127−0.257 to 0.401−0.229 to 0.4540.196 to 0.329−0.238 to 0.415−0.189 to 0.450

LC, Left coronary; |DE|, distance between the commissural point and the reference center; RC, right coronary; NC, noncoronary.

Relative sinus sizes: Correlation analysis LC, Left coronary; |DE|, distance between the commissural point and the reference center; RC, right coronary; NC, noncoronary.

Intraoperator Variability

The intraclass correlation was >0.9 for all measurements (P < .001), as shown in Table E2. The mean differences between the 2 measures were small and all close to zero and a good agreement at regression. The Bland-Altman plots are shown in Figure E3 and E4. Overall, the interrate variability was small, and the agreement between measurements was high.
Table E2

Intraclass correlation

Mean ± standard deviationP valueICCP value95% confidence interval
α12–0.13 ± 2.83.1520.996.0000.993-0.998
LCraphe1-LCraphe2–0.06 ± 0.53.7190.989.0000.980-0.994
Sinus LC1-Sinus LC20.02 ± 0.48.8230.992.0000.986-0.996
Sinus RC1-Sinus RC20.08 ± 0.60.6460.987.0000.975-0.993
Sinus NC1-Sinus NC2–0.04 ± 0.76.9820.988.0000.979-0.994

ICC, Intraclass correlation; LC, left coronary; RC, right coronary; NC, noncoronary.

Discussion

Aortic valve repair is a preferred option for patients with BAV because of its advantages over valve replacement. To choose the best repair strategy, advanced assessment of the geometric characteristics of the aortic valve must be mastered by all surgeons who want to perform valve-preserving surgery. Commissure orientation, defined as the angle α formed by the lines joining the commissures to the central axis of the valve, varies between 120° (tricuspid configuration) and 180° (bicuspid symmetrical shape). Schäfers and colleagues, showed that a commissural orientation as close as possible to 180°, by repositioning of the nonfused commissures, increases the durability of the repair by decreasing shear stress on the cusps. Other groups reported excellent results with α of 120° or 180°.,18, 19, 20 In this article, we presented a new CT–scan-based method that describes the aortic valve geometry in order to increase the understanding of the geometric morphology of the BAV. We tested the hypothesis that the coaptation angle α lacks a constant relationship with the exact position of the commissures. If this hypothesis is confirmed, the angle α alone might not be solely dependent on the true position of the commissure. Considering the true commissural angle β, we observed that the coaptation angle α significantly differs from the commissural angle β (P < .001). This suggests that the coaptation angle α indeed lacks a constant relationship with the exact position of the commissures. This was confirmed by the observation that even when the commissures were normally or near-normally positioned a commissural orientation α of 120° to 140° can be observed. The data showed a significant correlation of α with the length of the raphe (P = .008), which in contrast, did not correlate with β (P = .58). This finding might suggest that α is influenced by the length of the raphe rather than by the true commissural position. Moreover, we found that the angles γ1 and γ2 significantly differed from each other (P = .04), demonstrating that in many cases the raphe is not situated in the middle of the free edge and its coaptation midpoint can vary. This finding might suggest that the orientation of the raphe also has a different influence on α and β. The variability of the raphe's orientation is confirmed by the difference between the coaptation midpoint and the perfect center point |DE|. This segment, as well as the difference between the length of the raphe versus the length between the commissure and the circle midpoint (|AE| and AD|, respectively), were significantly correlated to Δαβ (both P values < .001). The coaptation angle α, on which valve repair decision making is partly based, may have no or minimal relationship with the true location of the 3 commissures, being more dependent on the length of the raphe instead. At the same time, β is dependent on the position of the nonfused commissures on a perfect circle, drawn through all 3 commissures. As a consequence, when considering the reposition of the commissures during remodeling or reimplantation, the surgeon could consider α and β separately. (Figure 3). Although midterm durability with commissural reorientation seems to be good, exact influence of this maneuver on mobility and shear stress of the fused cusp remains unknown. Further studies with 4-dimensional magnetic resonance flow imaging could help in elaborate on the effect of commissural repositioning on flow through the bicuspid valve.
Figure 3

The coaptation angle α was measured starting from the central coaptation point D. The angle α is measured with lines drawn from the coaptation point D through the 2 functional commissures B and C. The angle β was measured to geometric center E determined by the circle method. The circle is adjusted to contain the three commissures. The angle is measured with lines drawn from the center of the circle through the 2 functional commissures B and C.

The coaptation angle α was measured starting from the central coaptation point D. The angle α is measured with lines drawn from the coaptation point D through the 2 functional commissures B and C. The angle β was measured to geometric center E determined by the circle method. The circle is adjusted to contain the three commissures. The angle is measured with lines drawn from the center of the circle through the 2 functional commissures B and C. During valve surgery of BAV with righ/left fusion pattern it is often seen that the fused commissure, together with the commissure between the left and the noncoronary cusp, appears to be positioned at a fairly fixed point. In contrast, the commissure between the right and noncoronary cusp seems to be rather variable, mostly being displaced to the left. We hypothesized that if ε1 and ε2 differed from each other, this finding would demonstrate rather fixed positions of the commissures between the right and the left cusp and the left and noncoronary cusp. Angle ε2 should be quite constant to confirm this observation. In our experience, ε1 and ε2 differed from each other (P < .001) and ε2 was the most constant angle, compared with ε1 and β, suggesting that the position of the right commissure is less constant. At the same time, although ε2 is more fixed, its size geometrically depends on β. This reflects our experience during surgical inspection that the right:non commissure is frequently already positioned to the left. If this is correct, one might consider to only reposition the left/non commissure aiming at symmetrical fused cusp (ε1 = ε 2), this without the risk of damaging the atrioventricular conduction system. However, more measurements of ε2 are necessary to confirm the altered position of the commissure between the right and noncoronary cusps. This might be of clinical importance because the interleaflet triangle underneath the right and noncoronary cusp is closely related to the membranous septum, which contains the His bundle. Another observation was that the NCS was the largest sinus, and β was the primary determinant of its increased size in righ/left BAV. Considering this in the context of aortic valve repair, in case of a dilated NCS in right/left BAV, the Wolfe procedure (replacement of the supracoronary ascending aorta together with the dilated NCS) receives a Class IIa recommendation (level of evidence C). However, considering that the size of the NCS gets bigger when β increases, one might conclude this does not necessarily indicate that the NCS is pathologically as dilated as it seems. Unfortunately, the standard size of the NCS in the case of right/left BAV is unknown. Because the aortic root is globally dilated in most of our patients, this finding suggests that the NCS could be enlarged by design in right/left BAVs, rather than being a sign of pathological dilatation. To confirm this hypothesis, more sinus measurements should be performed at an early stage of life. In Video 1, the main findings of the study are explained by 1 of the authors. In the video, an author explains the main features of the study. Video available at: https://www.jtcvs.org/article/S2666-2507(21)00591-5/fulltext.

Clinical Application

Although the importance of these features and their clinical application, especially regarding the surgical decision making and techniques employed have to be further explored, we have started to include preoperative CT scan evaluation as described any time an aortic valve repair is planned. In Figure 4, a clinical case of a patient referred for BAV who underwent preoperative CT scan measurements and calculations is reported. CT scan, echocardiograph, and real-time measurements matched. The practice of repositioning the commissures as close to 180° as possible is being widely adopted by repair surgeons. Repositioning of the commissures (at the level of the sinotubular junction) implies the use of an annuloplasty ring inducing the same repositioning of the base of the interleaflet triangles (virtual basal ring). Indeed, if this is done only at the level of the commissures, the aortic valve is skewed by inducing alteration of the geometry of the valve. In the case shown, the patient underwent a Yacoub operation and we avoided aggressively repositioning the commissures based on the observation that the commissural position and the raphe significantly influence the coaptation angle (commissural orientation) more than previously believed and compared with the same commissural position on a virtual circle. As shown by the postrepair image, it was sufficient to pull on the commissures along the angle α to obtain a proper coaptation and an equal length of the plicated free edges. Hence, β was respected during the surgery as to not distort the valve.
Figure 4

Application of the method described during an aortic valve repair of a bicuspid aortic valve with right/left fusion pattern. A, Measurement of angle α on tranesophageal echocardiography. B, Measurement of angle β on transesophageal echocardiography. C, Measurement of of angle β on computed tomography scan. D, Intraoperative view of the uninstrumented aortic valve. E, Intraoperative assessment of angle β with a valve sizer. F, Intraoperative view after root remodeling and valve repair without annuloplasty and without repositioning of the nonfused commissures.

Application of the method described during an aortic valve repair of a bicuspid aortic valve with right/left fusion pattern. A, Measurement of angle α on tranesophageal echocardiography. B, Measurement of angle β on transesophageal echocardiography. C, Measurement of of angle β on computed tomography scan. D, Intraoperative view of the uninstrumented aortic valve. E, Intraoperative assessment of angle β with a valve sizer. F, Intraoperative view after root remodeling and valve repair without annuloplasty and without repositioning of the nonfused commissures.

Limitations of the Study

Our study presents some limitations that must be pointed out. First, the lack of a control group to confirm the correctness of the used measurements. Second, only 1 operator took the measurements. Although the method was proven to be reliable with an intraclass coefficient >0.90, a second observer and the calculation of interobserver agreement would have strengthened the study. Third, 2 different imaging software was used, and their equivalence was not tested, examining the same CT image using both software. Fourth, although unlikely, at present it is unknown whether the commissural position changes during progressive dilatation of the aortic root or even ascending aorta. Fifth, the potential of this method to improve the possibility of valve repair has to be deeply explored because about 50% of patients did not undergo surgery. Therefore, more patients in the valve repair group are necessary to correlate the BAV aortic geometry and the surgery decision making. Finally, the CT scan images are static, and they only assess structure, rather than function. In addition, CT images only assess structure at a single time point in the cardiac cycle. To study in a static state in diastole was decided to be able to make a comparison to the commissural orientation as described in the literature. Finally, most of the preoperative necessary information, necessary to judge repairability, comes from echocardiographic diastolic images (short and long axis images, +/- color flow).

Conclusions

The coaptation angle is dependent on both the commissural position and the length of the raphe. Considering the coaptation angle, the commissural position, and the length of the raphe separately and then reassembling them back together can give new perspectives on assessing the BAV design. This study confirms that BAV anatomy is even less uniform than already described, showing different lengths of the raphes even in completely fused cusps, commissural positions, and relative dimensions of sinuses. Further studies, including long-term follow-up and 4-dimensional flow magnetic resonance imaging, are needed to test whether these parameters are useful in BAV repair and whether these might have a beneficial influence on durable valve competence.

Conflict of Interest Statement

The authors reported no conflicts of interest. The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest.
  23 in total

1.  Clinical and pathophysiological implications of a bicuspid aortic valve.

Authors:  Paul W M Fedak; Subodh Verma; Tirone E David; Richard L Leask; Richard D Weisel; Jagdish Butany
Journal:  Circulation       Date:  2002-08-20       Impact factor: 29.690

2.  Preservation of the bicuspid aortic valve.

Authors:  Hans-Joachim Schäfers; Diana Aicher; Frank Langer; Henning F Lausberg
Journal:  Ann Thorac Surg       Date:  2007-02       Impact factor: 4.330

3.  A classification system for the bicuspid aortic valve from 304 surgical specimens.

Authors:  Hans-H Sievers; Claudia Schmidtke
Journal:  J Thorac Cardiovasc Surg       Date:  2007-05       Impact factor: 5.209

Review 4.  Genetic basis of familial valvular heart disease.

Authors:  Ratnasari Padang; Richard D Bagnall; Christopher Semsarian
Journal:  Circ Cardiovasc Genet       Date:  2012-10-01

5.  SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).

Authors:  Stephan Achenbach; Victoria Delgado; Jörg Hausleiter; Paul Schoenhagen; James K Min; Jonathon A Leipsic
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-11-14

6.  Leaflet reconstructive techniques for aortic valve repair.

Authors:  Domenico Mazzitelli; Christof Stamm; J Scott Rankin; Steffen Pfeiffer; Theodor Fischlein; Jan Pirk; Yeong-Hoon Choi; Christian Detter; Johannes Kroll; Friedhelm Beyersdorf; Malakh Shrestha; Christian Schreiber; Rüdiger Lange
Journal:  Ann Thorac Surg       Date:  2014-12-01       Impact factor: 4.330

7.  Long-term results of external aortic ring annuloplasty for aortic valve repair.

Authors:  Emmanuel Lansac; Isabelle Di Centa; Ghassan Sleilaty; Stephanie Lejeune; Nizar Khelil; Alain Berrebi; Christelle Diakov; Leila Mankoubi; Marie-Christine Malergue; Milena Noghin; Konstantinos Zannis; Suzanna Salvi; Patrice Dervanian; Mathieu Debauchez
Journal:  Eur J Cardiothorac Surg       Date:  2016-08       Impact factor: 4.191

8.  Tirone David valve-sparing aortic root replacement and cusp repair for bicuspid aortic valve disease.

Authors:  Fabian A Kari; David H Liang; John-Peder Escobar Kvitting; Elizabeth H Stephens; R Scott Mitchell; Michael P Fischbein; D Craig Miller
Journal:  J Thorac Cardiovasc Surg       Date:  2012-12-20       Impact factor: 5.209

9.  Early results with annular support in reconstruction of the bicuspid aortic valve.

Authors:  Diana Aicher; Ulrich Schneider; Wolfram Schmied; Takashi Kunihara; Masato Tochii; Hans-Joachim Schäfers
Journal:  J Thorac Cardiovasc Surg       Date:  2012-12-20       Impact factor: 5.209

10.  Cusp height in aortic valves.

Authors:  Hans-Joachim Schäfers; Wolfram Schmied; Gil Marom; Diana Aicher
Journal:  J Thorac Cardiovasc Surg       Date:  2012-07-31       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.