Literature DB >> 3497310

Inaccuracy of radial artery pressure measurement after cardiac operations.

R Mohr, J Lavee, D A Goor.   

Abstract

The phenomenon of a pressure gradient between central and radial arteries was evaluated in 48 patients immediately after coronary artery bypass operations. All were in stable hemodynamic condition, none receiving catecholamine support. In eight patients (Group A) mean femoral pressure was significantly higher than mean radial pressure (range 10 to 30 mm Hg). In the remaining 40 (Group B) radial and femoral pressures were equal. Mean cardiac index (thermodilution) was 3.3 +/- 0.68 versus 2.1 +/- 0.4 L/min/m2, systemic vascular resistance 1,181 +/- 218.4 versus 2,049 +/- 501 dynes/sec/cm-5, toe temperature 23.8 degrees +/- 1.2 degrees C versus 24.02 degrees +/- 0.9 degrees C, core temperature 33.9 degrees +/- 0.5 degrees C versus 34.1 degrees +/- 0.6 degrees C, mixed venous oxygen saturation 78% +/- 3% versus 62% +/- 5%, and peak radial dP/dt 1,485 +/- 366 versus 2,028 +/- 392 in Groups A and B, respectively. These data indicate, first, that the low radial pressures measured in Group A patients did not represent the true central aortic pressures; that is, they were false. Second, these low pressures had nothing to do with compromised cardiac function; rather, they were due to peripheral constriction and volume factors and also probably to proximal shunting. It is therefore recommended that while the chest is still open, if a discrepancy exists between a low radial artery pressure, a high palpable aortic pressure, and a satisfactory cardiac contraction, a femoral cannula for pressure measurement should be inserted. Treatment is by blood infusion until the femoral-radial gradient has been abolished.

Entities:  

Mesh:

Year:  1987        PMID: 3497310

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  Sustained effects of plasma norepinephrine levels on femoral-radial pressure gradient after cardiopulmonary bypass.

Authors:  R Nakayama; T Goto; I Kukita; R Sakata
Journal:  J Anesth       Date:  1993-01       Impact factor: 2.078

Review 2.  Hemodynamic monitoring during liver transplantation: A state of the art review.

Authors:  Mona Rezai Rudnick; Lorenzo De Marchi; Jeffrey S Plotkin
Journal:  World J Hepatol       Date:  2015-06-08

3.  Intraperitoneal hemorrhage following femoral artery cannulation for intraoperative monitoring: an unusual complication.

Authors:  E K Sim; F A Beynen; G K Danielson
Journal:  J Clin Monit       Date:  1993-09

4.  Early goal-directed therapy based on endotracheal bioimpedance cardiography: a prospective, randomized controlled study in coronary surgery.

Authors:  Jean-Luc Fellahi; David Brossier; Fabien Dechanet; Marc-Olivier Fischer; Vladimir Saplacan; Jean-Louis Gérard; Jean-Luc Hanouz
Journal:  J Clin Monit Comput       Date:  2014-11-09       Impact factor: 2.502

5.  Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output.

Authors:  Sumit Vasdev; Sandeep Chauhan; Minati Choudhury; Millind P Hote; Madhur Malik; Usha Kiran
Journal:  J Clin Monit Comput       Date:  2012-02-17       Impact factor: 2.502

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.