Abstract

Catheter ablation of recurrent atrial arrhythmias following pulmonary vein isolation can be challenging given the complex nature of previously ablated tissue, and managing these already complex cases may be rendered more difficult by the impact of wavefront directionality on mapping catheter orientation, which can make the accurate identification of arrhythmogenic substrate more difficult to achieve. In this report, a 72-year-old man with a history of symptomatic paroxysmal atrial fibrillation and prior pulmonary vein isolation (PVI) underwent repeat ablation. Importantly, this case study demonstrates how a direction-independent high-density mapping catheter (Advisor™ HD Grid; Abbott, Chicago, IL, USA) can identify fractionated low-voltage zones that may be missed when using a standard linear ablation catheter. Copyright:
© 2021 Innovations in Cardiac Rhythm Management.

Entities:  

Keywords:  Cardiac mapping; HD Grid; high density; wavefront

Year:  2021        PMID: 34970467      PMCID: PMC8712022          DOI: 10.19102/icrm.2021.121203

Source DB:  PubMed          Journal:  J Innov Card Rhythm Manag        ISSN: 2156-3977


Case presentation

Catheter ablation of recurrent atrial arrhythmias post–pulmonary vein isolation (PVI) can be challenging due to the complex nature of previously ablated tissue.[1] The challenges of these already complex cases can be compounded by the impact of wavefront directionality on mapping catheter orientation, thus complicating the accurate identification of arrhythmogenic substrate.[2] This case study demonstrates how a direction-independent high-density mapping catheter (Advisor™ HD Grid; Abbott, Chicago, IL, USA) can identify fractionated low-voltage zones that may be missed using a standard linear ablation catheter. A 72-year-old man with a history of symptomatic paroxysmal atrial fibrillation, and a prior PVI performed with a 28-mm cryoballoon catheter (Arctic Front™; Medtronic, Minneapolis, MN, USA), presented one year after the index PVI with recurrence of palpations. Electrocardiography was performed, which demonstrated an atrial tachycardia (AT) with 1:1 conduction. The patient opted for repeat electrophysiology study and ablation. The procedure was performed under general anesthesia. Catheters were positioned along the tricuspid annulus, His-bundle region, and coronary sinus (CS). The patient presented in tachycardia with a cycle length of 490 ms and eccentric CS catheter activation with earliest activation in the distal CS, indicating a left atrial origin (. Left atrial access was obtained via a transseptal puncture, and electroanatomic mapping (EnSite Precision™; Abbott, Chicago, IL, USA) was performed with a multi-electrode grid catheter. Activation and voltage mapping of the 490-ms tachycardia were simultaneously performed.[3] Dense scar zones were defined as regions where the local signal was less than 0.07 mV in amplitude. Both bipolar (30-Hz high-pass, 300-Hz low-pass, notch filter) and unipolar (0.5-Hz high-pass, 100-Hz low-pass, notch filter) filters were used to assess the left atrial signals and identify potential ablation targets. Entrainment mapping was performed on both the left atrial roof and mitral isthmus areas, indicating that those regions were not critical to the tachycardia. Activation mapping suggested a focal AT originating from the superior ostium of the left atrial appendage (. A low-voltage, fractionated signal was identified with the distal component 90 ms prior to the onset of the P-wave (. The location was marked on the three-dimensional map. The grid mapping catheter was exchanged for an externally irrigated ablation catheter (FlexAbility; Abbott), which was positioned at the suggested focal origin. Ablation catheter–tissue contact was confirmed using intracardiac echo and impedance. Neither the bipolar nor the unipolar atrial electrograms (EGMs) on the ablation catheter were able to be appreciated as they had appeared on the grid catheter, which produces EGMs independent of the electrode orientation to wavefront activation (. Radiofrequency (RF) energy was delivered at a power of 35 W. Within three seconds of RF application, the tachycardia terminated. The tachycardia was not re-inducible with burst atrial pacing down to 200 ms. At the time of the patient’s six-month follow-up, he remained arrhythmia-free. This is a case study and therefore did not undergo the institutional review board process.

Discussion

The incidence of ATs after cryoballoon ablation has been reported to be as high as 8%.[4] ATs can be focal or re-entrant, and are caused by one or a combination of triggered activity, enhanced automaticity, or reentrant activity. Furthermore, it has been shown that the substrate required for an AT may be correlated to areas of abnormal myocardium, such as those with fibrosis, hypertrophy, and thinning.[5] Fibrotic tissues produce signals which are difficult to discern, thereby increasing the level of complexity associated with mapping an AT.[3] Due to its grid design, the grid mapping catheter can assess the timing and voltage in a direction-independent manner, thereby reducing one of the challenges associated with these complex procedures. The catheter features a rectangular-shaped design with 16 1-mm electrodes that are equally spaced along the splines and across the splines (3 mm edge to edge). The electrical signals recorded between the orthogonal pairs are compared, and the highest amplitude signal is selected for the annotation of the localized timing (using EnSite Precision™; Abbott). This catheter design and algorithm allows for the creation of voltage and activation maps that are more accurate due to the reduction of “bipolar blindness”[2]—a phenomenon that occurs when the electrodes’ angle of incidence to the myocardium records near-simultaneous activation on both poles, thus canceling out most of the bipolar signal.[6] Our case demonstrates the contrast in appreciable signals between a grid catheter and a linear 3.5-mm tip ablation catheter. When the ablation catheter was placed at the successful site of termination, which had been identified by the grid catheter as early and fractionated, the earliest AT signal was not able to be readily identified (. This is potentially due to a combination of three variables that affect the resultant bipolar EGMs: electrode size, spacing, and incident angle.[7] First, the 3.5-mm distal electrode tip of the ablation catheter creates a large antenna, thereby acquiring a signal that is representative of a larger swath of tissue than that which is in contact with the ablator.[6] Second, the closest electrode pair to the tissue surface, excluding the large distal 3.5-mm antenna, is spaced 4 mm apart on the ablator. In contrast, the grid catheter’s electrodes have a 3-mm spacing and are able to acquire a more near-field signal.[6] Third, the ablation catheter’s linear design, and thus the singly oriented point of view, does not allow for a direction-independent analysis of wavefront propagation.[6] In an exposition of the current state of substrate-based ablation, Josephson et al. recommend standardized catheters with small electrodes and minimal interelectrode distance for minimizing poor resolution issues associated with recording techniques.[6] These recommendations, combined with the elimination of incident angle inaccuracy, allowed the grid catheter to create a detailed activation map of the tachycardia, allowing the authors to determine the tachycardia mechanism and identify the successful termination site.

Conclusion

The difference in appreciation between complex signals on a linear 3.5-mm tip ablation catheter and a grid-style high-density mapping catheter can be substantial. The inability of an ablation catheter to visualize one such complex signal does not negate the site’s viability for successful ablation. This case highlights the importance of collecting and analyzing complex circuits using a high-density, direction-independent mapping catheter.
  7 in total

Review 1.  Atrial tachycardia: mechanisms, diagnosis, and management.

Authors:  Kurt C Roberts-Thomson; Peter M Kistler; Jonathan M Kalman
Journal:  Curr Probl Cardiol       Date:  2005-10       Impact factor: 5.200

2.  Emergence of Multielectrode Mapping: On the Road to Higher Resolution.

Authors:  Roderick Tung; Kenneth A Ellenbogen
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-06

3.  Left atrial voltage mapping with a direction-independent grid catheter: Comparison with a conventional circular mapping catheter.

Authors:  Masaharu Masuda; Mitsutoshi Asai; Osamu Iida; Shin Okamoto; Takayuki Ishihara; Kiyonori Nanto; Takashi Kanda; Takuya Tsujimura; Yasuhiro Matsuda; Shota Okuno; Yosuke Hata; Toshiaki Mano
Journal:  J Cardiovasc Electrophysiol       Date:  2019-11-11

Review 4.  Substrate Mapping for Ventricular Tachycardia: Assumptions and Misconceptions.

Authors:  Mark E Josephson; Elad Anter
Journal:  JACC Clin Electrophysiol       Date:  2015-09-10

5.  Voltage and activation mapping: how the recording technique affects the outcome of catheter ablation procedures in patients with congenital heart disease.

Authors:  Natasja M S de Groot; Martin J Schalij; Katja Zeppenfeld; Nico A Blom; Enno T Van der Velde; Ernst E Van der Wall
Journal:  Circulation       Date:  2003-09-29       Impact factor: 29.690

6.  Regular atrial tachycardias developing after cryoballoon pulmonary vein isolation: incidence, characteristics, and predictors.

Authors:  Evgeny N Mikhaylov; Rohit Bhagwandien; Petter A Janse; Dominic A M J Theuns; Tamas Szili-Torok
Journal:  Europace       Date:  2013-05-19       Impact factor: 5.214

7.  Atrial tachycardia after ablation of persistent atrial fibrillation: identification of the critical isthmus with a combination of multielectrode activation mapping and targeted entrainment mapping.

Authors:  Anshul M Patel; Andre d'Avila; Petr Neuzil; Steven J Kim; Theofanie Mela; Jagmeet P Singh; Jeremy N Ruskin; Vivek Y Reddy
Journal:  Circ Arrhythm Electrophysiol       Date:  2008-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.