A Prospective Observational Clinical and Radiological Study of a Modular Bridging External Fixator for Unstable Distal Radius Fractures.

G Maccagnano1, G Noia1, G Vicenti2, M Coviello2, V Pesce1, B Moretti2.   

Abstract

INTRODUCTION: Distal Radius Fractures (DRFs), with a reported annual incidence of 600,000, are common injuries treated by trauma surgeons. This prospective observational study aims to assess the efficacy of a modular external fixation system in the treatment of unstable distal radius fractures at 12-months follow-up.
MATERIALS AND METHODS: Between December 2014 and December 2016, 35 patients (female: 21, male:14; mean age: 62.5), with unstable DRFs, treated with modular external fixation system, were selected for this prospective observational study. All the patients underwent clinical and radiological reviews at follow-up.
RESULTS: At 12-month follow-up, a mean DASH score of 15.73 and a mean PRWE score 20.10 were recorded. Mean radial inclination was 19.92°; mean ulnar variance was 1.12 mm and mean palmar inclination was 9.76°.
CONCLUSION: Modular external fixator system revealed clinically and radiologically effective in the treatment of unstable and comminuted DRFs. Additional K-wires should be used to complement the fracture fixation, when there is unacceptable fragment reduction only with external fixator.
© 2021 Malaysian Orthopaedic Association (MOA). All Rights Reserved.

Entities:  

Keywords:  closed reduction and internal fixation (CRIF); modular external fixator; radius fracture; unstable distal radius fracture; wrist fracture

Year:  2021        PMID: 34966503      PMCID: PMC8667251          DOI: 10.5704/MOJ.2111.016

Source DB:  PubMed          Journal:  Malays Orthop J        ISSN: 1985-2533


Introduction

Distal Radius Fractures (DRFs), with a reported annual incidence of 600,000, represent one of the common injuries treated by trauma surgeons[1]. These fractures tend to occur in a bimodal age distribution, in young patients involved in high-energy trauma and in elderly women after low-energy falls, secondary to osteoporosis[2]. Fracture comminution and articular involvement are more likely to be found in high-energy trauma[2-3]. Indications for a correct treatment of DRFs (surgical or non-surgical) have evolved over time. However, several controversies remain about the management of DRFs[4-6]. None of the twenty-nine recommendations of the American Academy of Orthopaedic Surgeons (AAOS) for distal radius practice guidelines were graded as strong[7]. Moreover, the Cochrane Database has shown that evidence is lacking regarding many aspects of the treatment of DRFs[4,8]. The optimal treatment of unstable DRFs is still a topic of debate and there is considerable disagreement about the need for strict anatomical restoration of the joint surface[4,9]. External fixation (EF) is a valid and simple method used for fixing unstable DRFs. A recent meta-analysis has shown that there were no significant different clinical outcomes in AO/OTA C-type managed with locking plates, compared with EF[10]. Modular external bridging fixator has replaced the previous fixed bridging, ensuring rapid mobilisation[11]. This prospective observational study aims to assess the efficacy of a recent bridging modular external fixation system in the treatment of unstable distal radius fractures at 12 months follow-up.

Materials and Methods

The present prospective observational study was started in December 2017. All patients with unstable DRFs, treated with modular external fixation system at our institution until December 2019 were potentially eligible for this study. Ethical approval was obtained from our centre’s clinical research ethics centre. The inclusion criteria were: (a) age of patient above 18 years; (b) presence of unstable DRFs; (c) maximum 14 days post-trauma interval; (d) high-energy or low-energy trauma. Exclusion criteria were: (a) bilateral wrist fracture; (b) concomitant carpal bones fracture; (c) history of rheumatoid arthritis or wrist arthrodesis; (d) contraindication to EF. The DRFs instability was defined as dorsal/volar comminution ratio >50%; dorsal/volar angle >20°; radial shortening >5-10mm; articular step-off >1mm; associated ulnar fracture[12-14]. All the patients underwent wrist radiographs, in anteroposterior and lateral views, at the outset, after surgery, at time of mobilisation, at external fixator removal and at 12 months follow-up. The radial inclination and ulnar variance were assessed in the anteroposterior views, and palmar inclination was evaluated in the lateral view. The radiological evaluation was performed independently by two orthopaedic surgeons with more than five years of experience in the field of upper limb traumatology. Clinical evaluation was performed, at baseline and at each follow-up visit, using the Disability of the Arm, Shoulder and Hand Score (DASH) and Patient-Related Wrist Evaluation (PRWE). The Range of Movement (ROM) and grip strength were also evaluated at each follow-up. All the surgical procedures were performed by the same surgical team. Fracture reduction was obtained by external manipulation, under C-arm control. The fracture was then stabilised using a modular external fixation system [Galaxy Wrist, Orthofix, Texas, USA], in bridge configuration. The two proximal screws were inserted in the middle third of the radial diaphysis located in the mediolateral position, taking care to avoid the brachioradialis tendon and the superficial radial nerve, or in the dorsolateral position, taking care to retract the long radial extensor tendon and extensor carpi radialis brevis. Next, through a small longitudinal surgical incision subcutaneous tissue dissection was performed and the two distal screws were implanted using as a landmark, the tubercle of the second metacarpal bone in the dorsolateral position, paying attention to the extensor tendon and the radiodorsal neurovascular bundle on the extensor aspect. After checking the correct position of the screws, two cover clamps proximal and distal, were closed to secure the screws. Then the wrist module with two rods in neutral position was attached to the two clamps. The wrist module has been designed to be particularly handy, permitting the central joint angulations up to ± 45° in the frontal and sagittal planes. The insertion of the bone screws and clamps assures that the fracture has been reduced by external manipulation and the EF construct fixed. If there was unacceptable fragment reduction with just the external fixator, K-wire were used additionally to complete the fracture stabilisation (Fig. 1 and 2).
Fig 1:

a) Pre-operative radiograph: the arrows showing angles for calculation of pre-operative radiological parameters. (b) Post-operative radiograph: the arrows showing use of K-wires to complement fracture reduction.

Fig 2:

Radiographs of right wrist (a) pre-operative, (b) post-operative, (c) after 12 months.

a) Pre-operative radiograph: the arrows showing angles for calculation of pre-operative radiological parameters. (b) Post-operative radiograph: the arrows showing use of K-wires to complement fracture reduction. Radiographs of right wrist (a) pre-operative, (b) post-operative, (c) after 12 months. All the patients were instructed in daily pin cleaning. Modular bridging external fixator allows wrist rapid mobilisation as early as the third week by unlocking the wrist module, as shown in surgical technique. The external fixator was removed in the seventh week post-op, the timing of application of these procedures was chosen case-by-case[11]. A suggestion, range of movement at the wrist is commenced by adjusting the setting at the wrist module. The decision to commence movement in the third post-operative week, supported by satisfactory reduction at surgery, or to remove the external fixator at seven weeks, is determined on a case-to-case basis. Statistical analysis was performed using STATA/MP 14 for Windows [Stata Corp LP, College Station, USA]. Paired t-test was used to assess variability between baseline and each follow-up. Pearson correlation test was performed. The tests were two-tailed; a p-value of less than 0.05 was considered significant.

Results

Thirty-five patients (female: 21, male:14; mean age: 62.5), with a mean follow-up of 14.95 months. The main data of the study are summarised in Table I.
Table I:

Main data of the study

Age
 Mean ±SD62.5±14.4
 Range27-75
Gender
 Male. n (%)21 (60%)
 Female. n (%)14 (40%)
BMI (Kg/m2)
 Mean ±SD27.6±6.4
Side
 Left. n (%)19 (54.29%)
 Right. n (%)16 (45.7%)
Smoking status
 # of smokers. n (%)6 (17.14%)
AO Classification
 23-B1. n (%)-
 23-B2. n (%)3 (8.57%)
 23-B3. n (%)4 (11.43%)
 23-C1. n (%)9 (25.7%)
 23-C2. n (%)12 (34.29)
 23-C3. n (%)7 (20%)
Type of trauma
 High-energy trauma. n (%)26(74.3%)
 Low-energy trauma. n (%)9 (25.7%)
Surgical time (min)
 Mean ±SD51±9.7
 Range42-67
Mobilisation timing (days)
 Mean ±SD24±8.5
 Range14-33
External Fixator Removal Timing
 Mean ±SD58.4±12.6
 Range46-74
Main data of the study Mean surgical time was 51 minutes (range 42-67). Only in two fractures out of 35 (5.71%), the surgical time was greater than 60 minutes; both fractures were classified as 23-C3, according to AO/OTA classification. 26 fractures out of 35 (74.3%) derived from low-energy trauma, whereas 9 fractures out of 35 were caused by high-energy trauma. Additional k-wires were used in 16 patients out of 35 (45.72%). Mean mobilisation time was 24 days (range 14-33 days). In all patients, after mobilisation the ROM 0-40° was allowed. Mean external fixator removal time was 58.4 days (range 46-74); Clinical and functional scores over time were summarised in Table II. A significant improvement of the DASH and PRWE scores was observed at time of mobilisation. No significant impairment of these scores were recorded at the following follow-ups (Table II). A significant improvement of the ROM and grip strength was observed at 6 months and 12-months follow up (Table II).
Table II:

Clinical outcome: differences between each follow-up versus baseline at left side and between each follow-up versus EF Removal at ride side (Paired t-test)

DASHPREWFlexionExtensionUlnar radial deviationGrip strength (kg)
Mean p Mean p Mean p Mean p Mean p Mean p
Baseline58.36-61.73-
EF Mobilisation48.70.03545.640.023
EF removal46.650.03242.560.02219.57-10.83-27.01-7.83-
6 months review35.430.0138.970.00234.740.00135.710.00145.800.00114.090.001
12 months review15.730.00120.100.00148.440.00156.560.00179.290.00127.830.001

EF= External Fixator; f.u.= follow-up

Clinical outcome: differences between each follow-up versus baseline at left side and between each follow-up versus EF Removal at ride side (Paired t-test) EF= External Fixator; f.u.= follow-up The radiological data are summarised in Table III: a significant improvement of radial inclination, ulnar variance and palmar inclination was observed post-operatively. No significant impairment of these parameters was recorded at the follow-up (Table III). No significant correlations were found between radiological parameters and clinical scores at 12 months follow-up analysing data with Pearson correlation test (Table IV).
Table III:

Radiological Analysis: differences at each follow-up review versus baseline (Paired t-test)

Radial inclination (°)Ulnar variance (mm)Palmar inclination (°)
Mean p Mean p Mean p
Baseline13.5--1.3-4.85-
Post-operatively210.0021.050.029.950.001
EF Mobilisation20.50.0031.200.019.950.001
EF removal20.390.0031.330.019.830.001
12 months review19.920.00351.120.019.760.001

EF= External Fixator; f.u.= follow-up

Table IV:

Correlation between radiological parameters and clinical scores at 12 months follow-up (Pearson Correlation Test)

DASHPREW
R p R p
Radial inclination0.320.0820.350.095
Ulnar variance0.240.2230.270.243
Palmar inclination0.310.0930.330.094
Radiological Analysis: differences at each follow-up review versus baseline (Paired t-test) EF= External Fixator; f.u.= follow-up Correlation between radiological parameters and clinical scores at 12 months follow-up (Pearson Correlation Test) Significant correlations were found between AO/OTA classification and additional K-wires analysing data with Pearson correlation test (Table V). The best clinical outcome, in terms of ROM restoration, was observed in type 23-B3 and 23-C1 injuries, although not statistically significant with Pearson correlation test (p>0.05).
Table V:

Correlation between AO/OTA classification and additional K-wires (Pearson Correlation Test)

AO/OTA classificationAdditional k-wiresP
NoYes
23-B2300.045
23-B340
23-C127
23-C266
23-C343
Correlation between AO/OTA classification and additional K-wires (Pearson Correlation Test)

Discussion

Distal radius (DRFs) fractures are one of the common injuries observed in orthopaedic clinical practice, with a reported high incidence in young patients involved in high-energy trauma and in post-menopausal women, as a consequence of low-energy trauma in osteoporotic bone[15]. In our study, DRFs were mainly observed in female patients (60%) and low-energy trauma was found to be the main cause of injury (74.3%). High-energy trauma was mainly observed in young male patients, with an age range of 27-42 years old. Open reduction and internal fixation (ORIF) often permits a stable construct and a good bone healing but results in cosmetically unacceptable incisions[16]. Considering the widespread use of minimally invasive technologies in other orthopaedic surgery[17,18] their use could be extended to trauma surgery whenever possible. The use of external wrist fixator permits an acceptable fracture healing without exposing the fracture site and compromising the bone vascularisation[19]. The significant correlations found between AO/OTA classification and additional K-wires analysing data with Pearson correlation test, shows that additional K-wires are useful in the fixation of fracture type 23-C1, 23-C2 where the articular part of radius is not badly fragmented. In these cases, the K-wires were used to fix these fragments, offering the advantage of limiting the distraction forces, thus reducing the effect of ligamentotaxis and improving fracture stability. After mobilisation, in 9 patients out of 35 a radial inclination mean loss of 2.3° was recorded; in 8 patients out of 35 a palmar inclination mean impairment of 1.5° was observed and in only 2 cases out of 35 an ulnar variance mean reduction of 1.5mm was observed. In none of these patients a revision surgical procedure was needed. The importance of the restoration of radiological parameters is still a matter of debate[20-23]. According to AAOS guidelines, surgery is recommended in fractures with radial shortening of more than 3mm, a dorsal tilt>10° and an articular step-off more than 2mm. Several studies, however, have shown no significant correlation between radiological parameters and clinical outcome[20-23]. In the current study, no significant correlation was recorded between DASH, PRWE scores and radiological parameters (radial inclination, ulnar variance and palmar inclination). On the external fixator removal, some limitation of ROM and grip strength was detected, especially in 23-C3 type injuries. At the subsequent follow-ups, however, a significant improvement of ROM and grip strength was recorded. This data is consistent with what is reported by Margaliot et al in a systematic review with meta-analysis[24]. Two complications were recorded in this study. A patient with a 23-C3 injury was found to have a loss of fracture reduction in the first post-operative week, requiring a surgical revision of the external fixator, adding K-wires. Another patient with a 23-B3 injury complained of pain at the fracture site at 60 days post-operatively, and the external fixator removal was delayed by fourteen days. This study has some limitations. Though the sample size is quite large, the lack of a randomised controlled group is a limitation of this study. The 12-month follow-up is too short to detect any arthritic changes of the wrist. To offset this, it is planned for all the patients to undergo a longer clinical-radiological follow-up.

Conclusion

This study revealed that the modular external fixator system clinically and radiologically was effective in the treatment of unstable and comminuted distal radial fractures. Additional K-wires were useful addition for fracture fixation when there is unacceptable fragment reduction only with external fixator.
  23 in total

Review 1.  Distal Radius Fractures in the Elderly.

Authors:  L Scott Levin; Joshua C Rozell; Nicholas Pulos
Journal:  J Am Acad Orthop Surg       Date:  2017-03       Impact factor: 3.020

2.  Treatment of distal radius fractures.

Authors:  David M Lichtman; Randipsingh R Bindra; Martin I Boyer; Matthew D Putnam; David Ring; David J Slutsky; John S Taras; William C Watters; Michael J Goldberg; Michael Keith; Charles M Turkelson; Janet L Wies; Robert H Haralson; Kevin M Boyer; Kristin Hitchcock; Laura Raymond
Journal:  J Am Acad Orthop Surg       Date:  2010-03       Impact factor: 3.020

Review 3.  Extensive Spinal Epidural Abscesses Resolved with Minimally Invasive Surgery: Two Case Reports and Review of the Recent Literature.

Authors:  Luca Proietti; Luca Ricciardi; Giovanni Noia; Giuseppe Barone; Eugenio Valenzi; Andrea Perna; Ilaria Giannelli; Laura Scaramuzzo; Massimiliano Visocchi; Fabio Papacci; Francesco Ciro Tamburrelli
Journal:  Acta Neurochir Suppl       Date:  2019

4.  Patient-Oriented Aesthetic Outcome After Lumbar Spine Surgery: A 1-Year Follow-Up Prospective Observational Study Comparing Minimally Invasive and Standard Open Procedures.

Authors:  Luca Ricciardi; Carmelo Lucio Sturiale; Resi Pucci; Gabriele Reale; Vito Stifano; Alessandro Izzo; Andrea Perna; Luca Proietti; Stefano Forcato; Krissia M Rivera Perla; Stefano El Boustany; Alessandro Olivi; Filippo Maria Polli
Journal:  World Neurosurg       Date:  2018-11-09       Impact factor: 2.104

5.  External fixation techniques for distal radius fractures.

Authors:  John T Capo; Kenneth G Swan; Virak Tan
Journal:  Clin Orthop Relat Res       Date:  2006-04       Impact factor: 4.176

Review 6.  The epidemiology of distal radius fractures.

Authors:  Kate W Nellans; Evan Kowalski; Kevin C Chung
Journal:  Hand Clin       Date:  2012-04-14       Impact factor: 1.907

Review 7.  Surgical interventions for treating distal radial fractures in adults.

Authors:  H H G Handoll; R Madhok
Journal:  Cochrane Database Syst Rev       Date:  2003

Review 8.  Management of Severely Comminuted Distal Radius Fractures.

Authors:  David M Brogan; Marc J Richard; David Ruch; Sanjeev Kakar
Journal:  J Hand Surg Am       Date:  2015-08-01       Impact factor: 2.230

9.  Intramedullary nailing for treatment of forearm non-union: Is it useful? - A case series.

Authors:  Rocco De Vitis; Marco Passiatore; Vitale Cilli; Jacopo Maffeis; Giuseppe Milano; Giuseppe Taccardo
Journal:  J Orthop       Date:  2020-01-10

10.  Modified Matti-Russe technique using a "butterfly bone graft" for treatment of scaphoid non-union.

Authors:  Rocco De Vitis; Marco Passiatore; Andrea Perna; Antonio Tulli; Antonio Pagliei; Giuseppe Taccardo
Journal:  J Orthop       Date:  2019-11-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.