Literature DB >> 34958655

A Comparative Study of the Clinical Efficacy and Safety of Pneumatic Trabeculoplasty and Selective Laser Trabeculoplasty for Patients with Primary Open-Angle Glaucoma or Ocular Hypertension.

Yanling Song1, Qiujie Song1, Yanhui Qin1, Jinfeng Xu1, Ping Chen1, Hong Li1, Wenjie Han1.   

Abstract

BACKGROUND We aimed to evaluate the efficacy and safety of pneumatic trabeculoplasty (PNT) and selective laser trabeculoplasty (SLT) in the treatment of primary open-angle glaucoma (POAG) and ocular hypertension (OHT). MATERIAL AND METHODS We randomly divided 120 cases (120 eyes) of POAG or OHT into 2 groups: PNT and SLT. The changes in anterior chamber angle, intraocular pressure (IOP), treatment effect, macular retinal ganglion cell complex (GCC) thickness, visual field, adverse reactions, and complications were observed before and 3 months after treatment. RESULTS In the PNT group, the opening range of anterior chamber angle at 1 week, 2 weeks, 1 month, and 3 months after surgery was significantly larger than that before surgery. In the SLT group, the open range of anterior chamber angle was significantly less than that before surgery at 1 week and 2 weeks after surgery. The open range of anterior chamber angle in the PNT group was significantly larger than that in the SLT group at 1 week, 2 weeks, 1 month, and 3 months after surgery. The mean IOP of the 2 groups decreased significantly after surgery. The postoperative mean IOP of the SLT group was significantly higher than that of the PNT group, and the decrease of IOP in the PNT group was significantly greater than that of the SLT group. The effective rate of the PNT group was higher than that of the SLT group. CONCLUSIONS Both PNT and SLT can reduce the IOP of patients with POAG and OHT. PNT appears to have better short-term treatment efficiency than SLT.

Entities:  

Mesh:

Year:  2021        PMID: 34958655      PMCID: PMC8719423          DOI: 10.12659/MSM.933454

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


Background

Glaucoma is an irreversible blinding eye disease. After cataract, it is the second leading cause of blindness in the world. Glaucoma is characterized by pathological increased intraocular pressure (IOP) and accompanied by irreversible damage of the optic nerve and visual function. Primary open-angle glaucoma (POAG) is an important part of primary glaucoma, and it is a group of diseases in which the IOP exceeds the tolerance of the optic nerve, resulting in optic nerve papilla damage and visual field defect; the angle of the chamber is open and the appearance is normal [1]. At present, there is no effective way to cure glaucoma. Reducing the IOP is the only effective way to prevent progression of glaucoma [2]. Ocular hypertension (OHT) refers to the physiological increase of IOP, excludes ocular or systemic diseases that affect IOP, and has high IOP (>21 mmHg) and open angle without optic disc and visual field changes [3]. OHT cannot be separated from POAG in the short term by current detection methods, which is also called suspected glaucoma or early glaucoma. The prevalence of OHT in people over 40 years old is 4%. About 0.5% to 1% of patients with OHT progress to POAG every year [4]. Pneumatic trabeculoplasty (PNT) is a new non-surgical treatment for glaucoma. The principle of reducing IOP can be explained as follows. The treatment ring is used as the corresponding area on the surface of the eyeball. In the process of vacuum suction, the beam net is pulled, so the resistance of aqueous humor through trabecular meshwork is reduced, and the IOP is reduced. During the process of vacuum suction, the passage between the uvea and sclera is widened and the IOP is decreased [5]. Studies have confirmed that PNT has the advantages of being non-invasive, safe, and convenient, and has a stable effect of reducing IOP in the short term compared to traditional treatment methods [6]. Selective laser trabeculoplasty (SLT) is a repeatable laser therapy for glaucoma and ocular hypertension without coagulative thermal injury. The basis of this method is as follows. A laser with specific wavelength can cause damage to pigment tissue and selectively act on target cells. The functional trabecular meshwork of the human eye is composed of 2 types of cells – the trabecular meshwork cells with pigment and the trabecular meshwork cells without pigment – so selective laser targeting therapy can be applied to the pigmented trabecular meshwork cells without damaging the surrounding tissues, and it can keep the structural integrity of trabecular tissue. After treatment, more cells differentiate in the trabecular meshwork, filtering part of the laser irradiation site. Therefore, the present randomized controlled trial study was performed to evaluate the effectiveness and safety of PNT and SLT by observing changes in anterior chamber angle, 24-h IOP, efficiency, ganglion cell complex (GCC), visual field, adverse reactions, and complications.

Material and Methods

Clinical data

Sample size calculation formula: In the formula, n represents the sample size of each group: α represents inspection level, which is 0.05, so Zα=1.96; β represents inspection efficiency, which is 0.9, so Zβ=1.28; σ represents the estimated value of the standard deviation of the mean intraocular pressure of all patients before treatment, σ=1.98 in this study; and δ represents the estimated value of the D-value between the mean intraocular pressure of PNT group and SLT group after treatment, δ=1.3 in this study. According to the above formula, 49 subjects are needed in each group. In addition, considering the possible loss to follow-up in the later stage, we estimated the loss to follow-up rate as 20%. Therefore, our study required at least 59 subjects in each group, and at least 118 subjects in 2 groups. We enrolled 120 patients (120 eyes) affected with POAG or OHT who were treated in the Ophthalmology Department of Dongying People’s Hospital (Shandong, China) from June 2019 to June 2020. Among them, 65 patients (65 eyes) had POAG and 55 patients (55 eyes) had OHT. There were 51 males and 69 females, with an age range of 19–77 years old, with an average age of (39.23±13.07) years old. All eyes were randomly divided into 2 groups, with 60 eyes in each group. The 2 groups were treated with PNT or SLT; according to surgical method, they were named the PNT group and SLT group. There was no significant difference in clinical data between the 2 groups, which was comparable (P>0.05) (Table 1).
Table 1

Characteristics of the studied population in the 2 groups.

PNT groupSLT groupt/χ2P
Gender0.1400.694
 Male24 (40.0%)27 (45.0%)
 Female36 (60.0%)33 (55.0%)
Left/right eyes0.0530.974
 Left27 (45.0%)29 (48.3%)
 Right33 (55.0%)31 (51.7%)
Age/years old38.87±15.0339.51±14.660.3430.842
BMI (kg/m2)22.39±2.3822.33±2.970.4460.656
Type of disease2.8540.870
 POAG31 (51.7%)34 (56.7%)
 OHT29 (48.3%)26 (43.3%)
Family history1.6280.443
 Positive6 (10.0%)5 (8.3%)
 Negative54 (90.0%)55 (91.7%)
Inclusion criteria: (1) over 18 years old; (2) diagnosed as POAG or OHT; (3) IOP less than 30 mmHg (1 mmHg=0.133 kPa); (4) diopter less than – 6 D; (5) no history of intraocular surgery or ocular trauma; (6) could follow up on time. Exclusion criteria: (1) in the advanced stage of POAG; (2) had vascular and neurological retinopathy that interferes with the results of this study, such as high myopia changes, degeneration, and holes; (3) a history of intraocular surgery, penetrating ocular trauma, or retinal laser treatment; (4) had serious corneal disease, systemic disease, mental disease, or could not complete the follow-up. The study was approved by the Ethics Committee of Dongying People’s Hospital (approval document No.: DY-IRB-20190021). Patients who participated in the study had complete clinical data. Signed written informed consents were obtained from the patients and/or guardians.

Ophthalmic Examination Methods

Optical Coherence Tomography (OCT)

OCT is a non-contact biological tissue imaging technology [7]. The scan mode of GCC (retinal ganglion cell complex in macular region) was selected. The GCC scan consists of 15 vertical scans covering a range of 7 mm2. The scanning center was 1 mm temporal to the macular fovea so as to better cover the temporal area. In addition, the scan also included a horizontal scan at the center to note the depth and perform a fovea search. With the fovea as the center, GCC-a is the average thickness, GCC-s is the upper average thickness, and GCC-i is the lower average thickness.

Visual inspection

A Humphrey – 750 automatic perimeter (Germany Zeiss company) was used for visual field inspection. Program settings were: Center 30-2 inspection procedures, white Stimulus III, 31.5 asb as background brightness, physiological blind spot gaze monitoring. After the whole process of computer processing, the visual field inspection result is given, which mainly includes mean visual field defect (MD) and pattern standard deviation (PSD). The difference from the average threshold of all detection sites and the mean of the same age patients without eye disease was MD, and it reflects the degree of decline in visual average sensitivity due to various reasons. MD may be due to refractive interstitial opacity or optic nerve damage. Detection of MD alone cannot judge specific eye diseases. Therefore, it is necessary to combine another indicator, namely PSD. PSD reflects the visual field irregularity caused by local visual field defect. This PSD result can filter out the decrease of visual sensitivity caused by refractive interstitial opacity. Therefore, this study combined MD and PSD for analysis.

Ultrasound Biomicroscopy (UBM) Inspection

The patient was placed in supine position, surface anesthesia was performed on the treated eye, we placed a bottomless eye cup in the conjunctival sac and injected sterile water for injection, then a UBM probe scanned vertically near the limbus [8]. Scanning methods: The limbal cornea has 4 quadrants throughout the week, all of which were scanned laterally and radiographically, focused on the observation of the anterior chamber angle and measured the anterior chamber depth. The anterior chamber depth could be measured, analyzed, and stored by the obtained images. The parameters of anterior chamber angle were defined as: taking the scleral process as the center of the circle, made a circle with a radius of 500 μm, then the degree of the angle formed by the intersection of the circle with the corneal endodermis and the iris anterior surface and the line between the scleral process was the degree of the anterior chamber angle.

Measurement of 24-h Mean IOP

We used a non-contact tonometer (Canon) for IOP measurement [9]. The subjects were not allowed to eat food or take medicine that affected IOP 1 week before the measurement, and were told not to drink alcohol. On the day of the measurement, the subject normally ate and drank water. All examinations were done by the same doctor each time the patient’s sitting IOP was measured; it measured 3 times for each eye and we took the average value. We measured IOP at 5: 00, 7: 00, 10: 00, 14: 00, 18: 00, 22: 00, then took the mean value. At 24 h, the mean IOP was measured before surgery and 1 day, 1 week, 2 weeks, 1 month, and 3 months after surgery.

Therapeutic Methods

Treatment of PNT [10]

The PNT1000 therapeutic instrument produced by Ophthalmic International (USA) was used, and it consists of host, treatment ring, and connecting pipe. The outer diameter of the large ring was 20 mm, the inner diameter was 19 mm, and the diameter of the small ring was 11 mm. The patient was in supine position. The affected eye was topically anesthetized with oxybuprocaine hydrochloride eye drops (Benoxil, Santen Pharmaceutical) for 5 min. The eyelids of the patient were gently opened with fingers. The vacuum suction ring was placed at the limbal of the cornea, and gently pressed down until the suction ring was completely adsorbed on the limbal of the cornea. After starting the machine, we set the maximum negative pressure level of 558.8 mmHg (1 kPa=7.5 mmHg) in advance, raised the IOP to 45–50 mmHg, leaving the vacuum suction ring on the limbus for 60 s, removed the vacuum suction ring, resting for 5 min, and repeat the treatment for 60 s.

Treatment of SLT [11]

The patient was in supine position. After topical anesthesia with 0.4% obucaine, the gonioscope was positioned and the treatment was performed with an Australian Ellex LT5106.S Solo laser. The laser wavelength was set at 532 nm, the pulse time was set at 3 ns, the spot diameter was 400 pm, and the pulse energy was 0.8 mJ. The whole trabecular meshwork width was irradiated, and the laser treatment range was 180 functional trabecular meshwork; when the laser irradiated the trabecular meshwork and produced bubbly bubbles, therapeutic energy was reduced to 0.5–1.4 mJ, each quadrant had about 25 points, and the total number of laser points was about 50. The laser beam focused on the area of the pigment trabecular meshwork, and the 400-pm diameter spot covered the pigment trabecular meshwork. Each spot was adjacent but not overlapped, and the final reaction of laser produced decolorized or fine bubbles. The laser energy was adjusted according to the pigment content of the patients. If there was more pigment, the energy was reduced appropriately. The total energy was recorded after surgery. The patients in both groups were forbidden to use hormonal or hormone containing antibiotic eye drops after surgery. The patients with severe anterior chamber reaction were given nonsteroidal anti-inflammatory drugs (diclofenac sodium or pranoprofen eye drops), 0.02 mL, 4 times a day, until 3 days after surgery.

Efficacy Evaluation

The effective rate evaluation method was as follows, according to the fourth edition of European Glaucoma guidelines (2014). If the initial treatment method reduces the IOP value ≥3 mmHg or the amplitude ≥20%, it is considered that the effect of reducing the IOP is exact. If the initial treatment cannot achieve the target IOP and the second treatment is needed, the effect of the added treatment to reduce the IOP by more than 15% is considered to be exact. The patients included in this study were in the latter situation, so we set the effective standard of treatment for the 2 groups of patients as IOP reduction ≥15%. The effective rate was the number of patients with a definite effect divided by the total number of patients in the group.

Postoperative Follow-Up

We measured and recorded the anterior chamber angle, IOP, macular GCC thickness, and visual field were recorded 2 h before surgery and at 1 week, 2 weeks, 1 month, and 3 months after surgery. We measured and recorded the open range of anterior chamber angle and the IOP of selected patients at 1 h, 1 day, 1 week, 2 weeks, 1 month, and 3 months after the surgery. The IOP values at other timepoints were the mean IOP of 24 h, except for 1 h after surgery. The visual field and visual acuity were recorded 3 months after surgery. We also assessed and recorded the number of adverse reactions to 1 h and 1 day after surgery.

Statistical Analysis

SPSS 23.0 software (IBM Corp.) was used for the statistical analysis of the data. The visual acuity and intraocular pressure before and after surgery are expressed as χ̄±s. The independent sample t test was used to compare the same index between the 2 groups before surgery, and the paired sample t test was used to compare the same index before and after surgery. Repeated measurement analysis of variance was used to compare the same index at different times. The χ2 test was used to compare the success rate and incidence rate of complications between the 2 groups. The inspection level was α=0.05.

Results

Results of Anterior Chamber Angle

Before surgery, there was no significant difference in the open range of anterior chamber angle between the 2 groups (P>0.05). After surgery, there was no angle adhesion in the 2 groups. In PNT group, the opening range of anterior chamber angle at 1 week, 2 weeks, 1 month, and 3 months after surgery was significantly larger than that before surgery (P<0.05). In the SLT group, the opening range of the anterior chamber angle at 1 week and 2 weeks after surgery was significantly smaller than that before surgery (P<0.05), and there was no significant difference in the opening range of anterior chamber angle between 1 month and 3 months after surgery (P>0.05). The open range of the anterior chamber angle in the PNT group was significantly larger than that in the SLT group at 1 week, 2 weeks, 1 month, and 3 months after surgery (<0.05) (Table 2).
Table 2

Changes of anterior chamber angle opening range before and after surgery (χ̄±s, degree).

TimePNT group (n=60)SLT group (n=60)Comparison of before and after operation of PNT groupComparison of before and after operation of SLT groupComparison between PNT group and SLT group
t1P1t2P2t2P3
2 h before operation28.73±1.3128.75±1.611.3540.574
1 w after operation31.01±1.0526.31±2.074.3470.0038.420.00010.2960.000
2 w after operation30.68±1.4727.15±2.235.5140.0016.710.0008.3570.000
1 m after operation29.80±1.2928.33±2.197.0360.0001.930.6314.0750.005
3 m after operation29.21±1.1728.81±2.746.5570.0002.070.8153.4980.012

Results of IOP

Changes in IOP at each timepoint before and after surgery and the decrease at each timepoint after surgery in the 2 groups (%) are shown in Figure 1. There was no significant difference in IOP between the PNT group and SLT group (P>0.05). At 1 h, 1 day, 1 week, 2 weeks, 1 month, and 3 months after surgery the mean IOP of the 2 groups decreased significantly (P<0.05). There were significant differences in mean IOP between the PNT group and SLT group. IOP in the SLT group was significantly higher than that in the PNT group at 1 h, 1 day, 1 week, 2 weeks, 1 month, and 3 months after surgery (P<0.05). From the decrease of IOP, there were significant differences between the 2 groups at each timepoint after surgery. The decrease in IOP in the PNT group was significantly greater than that in the SLT group (P<0.05).
Figure 1

The changes of IOP. (A) Paired samples t test for mean IOP of PNT group and SLT group, t before surgery=1.039, t1 h=−3.885, t1 d=−2.134, t1 w=−3.353, t2 w=−2.641, t1 m=−3.927, t3 m=−3.134, P before surgery=0.862, P1 h=0.005, P1 d=0.013, P1 w=0.007, P2 w=0.011, P1 m=0.004, P3 m=0.006; (B) Independent samples t test for decreased percentage of IOP after surgery, t1 h=9.341, t1 d=3.945, t1 w=7.205, t2 w=4.458, t1 m=8.266, t3 m=6.473, P1 h=0.000, P1 d=0.003, P1 w=0.000, P2 w=0.000, p1 m=0.000, P3 m=0.000.

Results of Effective Rate

After PNT or SLT surgery, the number of effectively treated patients and the effective rate of the 2 groups first increased and then decreased. At 1 h after surgery, the effective rate of the 2 groups was the lowest, at 28.3% in the PNT group and 3.3% in the SLT group. The maximum effective rate was 98.3% in the PNT group 1 m after surgery, and 78.3% in the SLT group 2 weeks after surgery; 3 months after surgery, the effective rates of the PNT group and SLT group were lower than before, at 88.3% and 61.7%, respectively. The effective rate of the PNT group was higher than that of the SLT group at each timepoint after surgery. The chi-square test showed that the difference between the 2 groups at each timepoint was statistically significant (P<0.05) (Table 3).
Table 3

Effective rate at different timepoints after surgery [eye (%)].

1 h after operation1 d after operation1 w after operation2 w after operation1 m after operation3 m after operation
PNT group17 (28.3%)43 (71.7%)51 (85.0%)55 (91.7%)59 (98.3%)53 (88.3%)
SLT group2 (3.3%)19 (31.7%)27 (45.0%)47 (78.3%)41 (68.3%)37 (61.7%)
χ214.07019.22121.0094.18319.40011.378
P0.0000.0000.0000.0410.0000.001

Results of GCC

Before surgery, there was no significant difference in the preoperative GCC-a, GCC-s, and GCC-i between the 2 groups. There was no statistically significant difference in GCC thickness before and 3 months after surgery. At 3 months after surgery, there was no significant difference in GCC-a, GCC-s, and GCC-i between the PNT group and SLT group (P>0.05) (Table 4).
Table 4

GCC thickness in different areas of macular area before and after surgery (χ̄±s, μm).

PNT groupSLT group
GCC-aGCC-sGCC-iGCC-aGCC-sGCC-i
Before operation95.01±10.5394.33±9.7295.26±10.3494.93±9.3195.06±10.2294.36±10.15
3 m after operation94.36±10.2494.27±9.3394.49±9.7694.01±10.3994.45±10.2194.25±10.11

Results of Visual Field

There was no significant difference in MD and PSD between the PNT group and SLT group before surgery; 3 months after surgery, the MD and PSD of the 2 groups had some changes, but there was no significant difference before and after surgery. There was no significant difference in the MD and PSD between the 2 groups 3 months after surgery (P>0.05) (Table 5).
Table 5

Comparison of visual field before and after surgery (χ̄±s, dB).

PNT groupSLT group
MDPSDMDPSD
Before operation−3.75±0.984.59±1.31−3.63±1.174.51±0.91
3 m after operation−3.84±1.074.69±1.53−3.79±1.214.73±1.02

Results of Adverse Reactions and Complications

After PNT and SLT treatment, no serious complications occurred in the 2 groups. The adverse reactions 1 h and 1 day after surgery are shown in Table 6. At 1 h after surgery, conjunctival congestion occurred in all patients, and most of them subsided 1 day after surgery. Eleven 11 eyes (18.3%) in the PNT group and 29 eyes (48.3%) in the SLT group had postoperative IOP rebound, with the highest rebound IOP of 6 mmHg (33%). Some patients in the 2 groups recovered to below the preoperative IOP level at 1 day after surgery without increasing medication. Twenty-one eyes (35.0%) in the PNT group and 11 eyes (18.3%) in the SLT group had subconjunctival punctate and patchy hemorrhage, which disappeared 1 day to 1 week after surgery. Intraoperative and postoperative ocular distension occurred in 7 eyes (11.7%) in the PNT group and 15 eyes (25.0%) in the SLT group. Most of the patients’ symptoms disappeared from 1 day to 1 week after surgery.
Table 6

Incidence of adverse reactions and complications (eye).

1 h after operation1 d after operation
PNT groupSLT groupPNT groupSLT group
Conjunctiva congestion60601114
IOP rebound1129513
Conjunctiva bleeding211132
Eye swelling71522
Eye foreign body sensation10741
Photophobia, tears4701
Others8743

Discussion

The main manifestations of POAG are optic atrophy and visual field defect. The pathological mechanism of glaucoma is that resistance of the trabecular meshwork to aqueous humor is increased, which leads to increased IOP, then the retinal ganglion cells are progressively lost and the optic nerve fibers are damaged irreversibly [12]. There are 2 proposed mechanisms of trabecular meshwork lesions: one is the change of the composition and content of the matrix outside the trabecular meshwork, which makes the trabecular meshwork narrow and collapse; the other is the abnormal cytoskeleton of trabecular meshwork cells, which leads to the decrease of their contractility [2]. OHT is a special phenomenon in the diagnosis and treatment of POAG after decades of clinical experience, which is different from open angle glaucoma [4]. Epidemiological data show that OHT is more common than POAG, and some patients with OHT develop into POAG [4]. OHT develops slowly; it rarely causes damage to the optic nerve and visual field, but it has the same important pathological factor as open-angle glaucoma, that is, high IOP [3]. IOP is the only risk factor that can be controlled in the treatment of glaucoma. The aim of glaucoma treatment is to preserve existing visual function, stabilize the optic nerve and retinal nerve fiber layer, and prevent further visual field damage [2]. Reducing IOP is an effective way to preserve visual function. At present, the main means of IOP control are drug therapy and surgical treatment, which have shortcomings in reducing IOP, including adverse effects of drugs, decreased tolerance caused by ocular surface damage, fluctuation of IOP caused by poor compliance, and the complications of surgery and risk of resurgery [13]. It is worth noting that both eyes of POAG and OHT patients are affected. In order not to affect the treatment effect, in this study, the same treatment mode and surgery method were used for both eyes of the same patient. The data obtained from 2 eyes of the same patient often have a strong positive correlation, which means that the amount of information provided by 2 eyes of 1 person is less than that provided by the single eyes of 2 person. In an extreme case, 2 eyes of the same patient may provide exactly the same information, and the other eye of that person may not provide additional information. Therefore, the data provided by 1 person’s 2 eyes cannot be regarded as being the same as the monocular data of 2 persons [14]. In this study, even if both eyes of the patients met the inclusion criteria, only 1 eye of each patient was included as the research subject, and the selection method was random selection. The exact mechanism of PNT in the treatment of glaucoma is still unclear. It may be that the trabecular meshwork is extended and expanded under the action of the treatment ring and continuous negative pressure mechanical traction, thus improving the outflow of aqueous humor [6]. PNT mainly acts on the trabecular meshwork, and can also affect the uveoscleral channel. The mechanism of SLT in lowering IOP has not been fully elucidated. In vitro culture experiments have shown that a short-pulse low-energy 532 nm frequency doubled laser can selectively act on cultured trabecular meshwork pigment cells without causing thermal damage to surrounding non-pigment tissues [15]. This study showed that the anterior chamber angle was significantly widened after PNT at 1 week, 2 weeks, 1 month, and 3 months after surgery. The opening range of anterior chamber angle was significantly larger than that before surgery (P < 0.05), but after SLT treatment, the open range of anterior chamber angle was significantly smaller than that before surgery at 1 week and 2 weeks (P<0.05), and there was no significant difference between 1 month and 3 months (P>0.05), indicating that PNT can increase the open range of the anterior chamber angle, while SLT can reduce the open range of anterior chamber angle to a certain extent. However, there was no angle adhesion in the 2 groups, which fully confirmed the safety of the 2 treatment methods. PNT is a non-invasive treatment. It has been reported that PNT can reduce the IOP in patients with POAG and OHT [16]. SLT is also an effective method to reduce the IOP in patients with POAG and OHT. Through 5 years of follow-up observation, Juzych et al [17] found that SLT can reduce the IOP of patients, and the reduction is from 18.1% in the first year to 27.1% in the fifth year, which fully proves the effect of this method in reducing IOP. These results are consistent with the results of the present study. We studied the changes of mean IOP before and after PNT and SLT, and we found that both methods can significantly reduce the IOP of patients, and the decrease amplitude of the PNT group is higher than that of the SLT group, indicating that the effect of PNT is better than that of SLT in reducing IOP. The reason for this result may be that PNT is a physical treatment based on the effect of reducing intraocular pressure by negative pressure suction during excimer laser in situ keratomileusis. The onset time of PNT is short, but the long-term effect needs to be further studied. SLT improves the porosity of the trabecular meshwork by upregulating the expression of matrix metalloproteinases, cytokines, and macrophages, which is not a purely physical method. SLT needs internal regulation to take effect, so the onset time is longer than with PNT, but the control of intraocular pressure may have a more lasting long-term effect, which needs further research. The observation time of this study mainly includes the period from before treatment to 3 months after treatment. This period can only show that the short-term effect of PNT is better than that of SLT, and the long-term effect needs to be further studied. The main pathological changes of POAG and OHT are retinal ganglion cell apoptosis, resulting in optic nerve damage and visual field defect [18]. At present, most studies have focused on the defect of the optic nerve fiber layer, but the thickness of macular area, as the concentration of retinal ganglion cells, can reflect the pathological changes of glaucoma [19]. Some studies have found that the macular structure consists of only a nerve fiber layer, ganglion cell layer, and inner plexiform layer. These 3 layers are significantly damaged in glaucoma. These 3 layers are called GCC [20]. Therefore, observing the changes of GCC can further diagnose and follow up the progression of disease [21]. OCT can be used to check the GCC examination, with high accuracy and repeatability, and the process of checking the thickness of GCC in the macular area is simpler than in the optic nerve fiber layer [22]. Therefore, in the present study, OCT was used to compare GCC-a, GCC-s, and GCC-i before and 3 months after PNT or SLT, and we found that the differences were not statistically significant (P>0.05). In addition, the visual fields of patients before and 3 months after PNT were compared, we found that there was no significant difference between the 2 groups (P>0.05), indicating that PNT and SLT are safe. The adverse reactions of PNT and SLT are less, and they need no treatment and can disappear within a few days. No serious complications occurred during and after PNT treatment in this study. According to the statistics of adverse reactions 1 h after surgery and 1 days after surgery, we found that the adverse reactions mainly included mild conjunctival edema and congestion, conjunctival bleeding, and some mild discomfort. These symptoms usually disappeared 1–3 days after surgery, and 1 week at the most. In this study, no serious adverse reactions or complications were found, and no visual field defect or retinal ganglion cell damage were found. There were fewer adverse reactions with PNT than with SLT, and there were relatively few adverse reactions with PNT. Limitations of this study include the small sample size and short observation period. The stability, long-term complications, repeatability, cross-reactions of drugs, and whether it is suitable for other types of glaucoma need further study and discussion.

Conclusions

PNT and SLT can reduce the IOP of patients with POAG and OHT. The postoperative adverse reactions are mild, safety is high, and they can be used as an alternative treatment for such diseases. The short-term effect of PNT is better than that of SLT in increasing the opening range of anterior chamber angle and reducing IOP, and there were fewer adverse reactions in the PNT group. In addition, PNT is simple and non-invasive and patient compliance is high, which helps improve patients’ cooperation with treatment and ensures smooth surgery. Therefore, it PNT is conducive to patients’ postoperative rehabilitation, so that patients can recover their vision as soon as possible, and it warrants consideration for use in clinical practice.
  22 in total

1.  Impact of laser pulse duration on the reduction of intraocular pressure during selective laser trabeculoplasty.

Authors:  Spela Stunf Pukl; Brigita Drnovšek-Olup
Journal:  Int Ophthalmol       Date:  2016-12-31       Impact factor: 2.031

Review 2.  [Primary open-angle glaucoma].

Authors:  S Bertaud; V Aragno; C Baudouin; A Labbé
Journal:  Rev Med Interne       Date:  2018-12-26       Impact factor: 0.728

Review 3.  Statistical guidelines for the analysis of data obtained from one or both eyes.

Authors:  Richard A Armstrong
Journal:  Ophthalmic Physiol Opt       Date:  2013-01       Impact factor: 3.117

Review 4.  Pathophysiology of primary open-angle glaucoma from a neuroinflammatory and neurotoxicity perspective: a review of the literature.

Authors:  Karine Evangelho; Maria Mogilevskaya; Monica Losada-Barragan; Jeinny Karina Vargas-Sanchez
Journal:  Int Ophthalmol       Date:  2017-12-30       Impact factor: 2.031

5.  Fourier domain OCT measurement of macular, macular ganglion cell complex, and peripapillary RNFL thickness in glaucomatous Chinese eyes.

Authors:  Junyi Chen; Haili Huang; Min Wang; Xinghuai Sun; Shaohong Qian
Journal:  Eur J Ophthalmol       Date:  2012-03-20       Impact factor: 2.597

6.  Prevalence of primary open angle glaucoma in a rural adult Chinese population: the Handan eye study.

Authors:  Yuan Bo Liang; David S Friedman; Qiang Zhou; Xiaohui Yang; Lan Ping Sun; Li Xia Guo; Qiu Shan Tao; Dolly S Chang; Ning Li Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-21       Impact factor: 4.799

7.  Macular and peripapillary retinal nerve fiber layer measurements by spectral domain optical coherence tomography in normal-tension glaucoma.

Authors:  Mincheol Seong; Kyung Rim Sung; Eun Hee Choi; Sung Yong Kang; Jung Woo Cho; Tae Woong Um; Yoon Jeon Kim; Seong Bae Park; Hun Eui Hong; Michael S Kook
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-10-15       Impact factor: 4.799

8.  Fibrovascular ingrowth at sclerotomy sites in vitrectomized diabetic eyes with recurrent vitreous hemorrhage: ultrasound biomicroscopy findings.

Authors:  Vrinda S Hershberger; James J Augsburger; Robert K Hutchins; Lawrence A Raymond; Stewart Krug
Journal:  Ophthalmology       Date:  2004-06       Impact factor: 12.079

9.  Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes.

Authors:  John H K Liu; Xiaoyan Zhang; Daniel F Kripke; Robert N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-04       Impact factor: 4.799

Review 10.  Efficacy and safety of different regimens for primary open-angle glaucoma or ocular hypertension: a systematic review and network meta-analysis.

Authors:  Fei Li; Wenbin Huang; Xiulan Zhang
Journal:  Acta Ophthalmol       Date:  2017-11-16       Impact factor: 3.761

View more
  1 in total

1.  Hub Gene Screening Associated with Early Glaucoma: An Integrated Bioinformatics Analysis.

Authors:  Rui Tian; Fuqiang Li; Songtian Che; Meijiao Song; Lu Liu; Rong Guo; Zhuoya Li; Xiaomin Hu; Hui Zhang
Journal:  Comput Math Methods Med       Date:  2022-07-15       Impact factor: 2.809

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.