Literature DB >> 34958166

In Vivo Absolute Metabolite Quantification Using a Multiplexed ERETIC-RX Array Coil for Whole-Brain MR Spectroscopic Imaging.

Bijaya Thapa1,2, Azma Mareyam1, Jason Stockmann1,2, Bernhard Strasser1,2, Boris Keil3, Philipp Hoecht4, Stefan A Carp1,2, Xianqi Li1,2, Zhe Wang5, Yulin V Chang5, Jorg Dietrich2,6, Erik Uhlmann2,7, Daniel P Cahill2,8, Tracy Batchelor2,9,10, Lawrence Wald1,2, Ovidiu C Andronesi1,2.   

Abstract

BACKGROUND: Absolute quantification of metabolites in MR spectroscopic imaging (MRSI) requires a stable reference signal of known concentration. The Electronic REference To access In vivo Concentrations (ERETIC) has shown great promise but has not been applied in patients and 3D MRSI. ERETIC hardware has not been integrated with receive arrays due to technical challenges, such as coil combination and unwanted coupling between multiple ERETIC and receive channels, for which we developed mitigation strategies.
PURPOSE: To develop absolute quantification for whole-brain MRSI in glioma patients. STUDY TYPE: Prospective. POPULATION: Five healthy volunteers and three patients with isocitrate dehydrogenase mutant glioma (27% female). Calibration and coil loading phantoms. FIELD STRENGTH/SEQUENCE: A 3 T; Adiabatic spin-echo spiral 3D MRSI with real-time motion correction, Fluid Attenuated Inversion Recovery (FLAIR), Gradient Recalled Echo (GRE), Multi-echo Magnetization Prepared Rapid Acquisition of Gradient Echo (MEMPRAGE). ASSESSMENT: Absolute quantification was performed for five brain metabolites (total N-acetyl-aspartate [NAA]/creatine/choline, glutamine + glutamate, myo-inositol) and the oncometabolite 2-hydroxyglutarate using a custom-built 4x-ERETIC/8x-receive array coil. Metabolite quantification was performed with both EREIC and internal water reference methods. ERETIC signal was transmitted via optical link and used to correct coil loading. Inductive and radiative coupling between ERETIC and receive channels were measured. STATISTICAL TESTS: ERETIC and internal water methods for metabolite quantification were compared using Bland-Altman (BA) analysis and the nonparametric Mann-Whitney test. P < 0.05 was considered statistically significant.
RESULTS: ERETIC could be integrated in receive arrays and inductive coupling dominated (5-886 times) radiative coupling. Phantoms show proportional scaling of the ERETIC signal with coil loading. The BA analysis demonstrated very good agreement (3.3% ± 1.6%) in healthy volunteers, while there was a large difference (36.1% ± 3.8%) in glioma tumors between metabolite concentrations by ERETIC and internal water quantification.
CONCLUSION: Our results indicate that ERETIC integrated with receive arrays and whole-brain MRSI is feasible for brain metabolites quantification. Further validation is required to probe that ERETIC provides more accurate metabolite concentration in glioma patients. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.
© 2021 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  2-hydroxyglutarate; Electronic REference To access In vivo Concentrations; absolute quantification; glioma; isocitrate dehydrogenase; magnetic resonance spectroscopic imaging; metabolism; receive array

Mesh:

Substances:

Year:  2021        PMID: 34958166      PMCID: PMC9189023          DOI: 10.1002/jmri.28028

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   5.119


  35 in total

1.  Noise correlations in data simultaneously acquired from multiple surface coil arrays.

Authors:  C E Hayes; P B Roemer
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

2.  User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability.

Authors:  Paul A Yushkevich; Joseph Piven; Heather Cody Hazlett; Rachel Gimpel Smith; Sean Ho; James C Gee; Guido Gerig
Journal:  Neuroimage       Date:  2006-03-20       Impact factor: 6.556

3.  Lipid suppression in CSI with spatial priors and highly undersampled peripheral k-space.

Authors:  Berkin Bilgic; Borjan Gagoski; Trina Kok; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2012-07-17       Impact factor: 4.668

4.  WET, a T1- and B1-insensitive water-suppression method for in vivo localized 1H NMR spectroscopy.

Authors:  R J Ogg; P B Kingsley; J S Taylor
Journal:  J Magn Reson B       Date:  1994-05

5.  Cancer-associated IDH1 mutations produce 2-hydroxyglutarate.

Authors:  Lenny Dang; David W White; Stefan Gross; Bryson D Bennett; Mark A Bittinger; Edward M Driggers; Valeria R Fantin; Hyun Gyung Jang; Shengfang Jin; Marie C Keenan; Kevin M Marks; Robert M Prins; Patrick S Ward; Katharine E Yen; Linda M Liau; Joshua D Rabinowitz; Lewis C Cantley; Craig B Thompson; Matthew G Vander Heiden; Shinsan M Su
Journal:  Nature       Date:  2009-12-10       Impact factor: 49.962

6.  Quantitation of proton NMR spectra of the human brain using tissue water as an internal concentration reference.

Authors:  P B Barker; B J Soher; S J Blackband; J C Chatham; V P Mathews; R N Bryan
Journal:  NMR Biomed       Date:  1993 Jan-Feb       Impact factor: 4.044

7.  An integrated genomic analysis of human glioblastoma multiforme.

Authors:  D Williams Parsons; Siân Jones; Xiaosong Zhang; Jimmy Cheng-Ho Lin; Rebecca J Leary; Philipp Angenendt; Parminder Mankoo; Hannah Carter; I-Mei Siu; Gary L Gallia; Alessandro Olivi; Roger McLendon; B Ahmed Rasheed; Stephen Keir; Tatiana Nikolskaya; Yuri Nikolsky; Dana A Busam; Hanna Tekleab; Luis A Diaz; James Hartigan; Doug R Smith; Robert L Strausberg; Suely Kazue Nagahashi Marie; Sueli Mieko Oba Shinjo; Hai Yan; Gregory J Riggins; Darell D Bigner; Rachel Karchin; Nick Papadopoulos; Giovanni Parmigiani; Bert Vogelstein; Victor E Velculescu; Kenneth W Kinzler
Journal:  Science       Date:  2008-09-04       Impact factor: 47.728

8.  Quantitative assessment of the effects of water proton concentration and water T1 changes on amide proton transfer (APT) and nuclear overhauser enhancement (NOE) MRI: The origin of the APT imaging signal in brain tumor.

Authors:  Dong-Hoon Lee; Hye-Young Heo; Kai Zhang; Yi Zhang; Shanshan Jiang; Xuna Zhao; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2016-02-02       Impact factor: 4.668

9.  Real-time motion- and B0-correction for LASER-localized spiral-accelerated 3D-MRSI of the brain at 3T.

Authors:  Wolfgang Bogner; Aaron T Hess; Borjan Gagoski; M Dylan Tisdall; Andre J W van der Kouwe; Siegfried Trattnig; Bruce Rosen; Ovidiu C Andronesi
Journal:  Neuroimage       Date:  2013-11-05       Impact factor: 6.556

10.  Pharmacodynamics of mutant-IDH1 inhibitors in glioma patients probed by in vivo 3D MRS imaging of 2-hydroxyglutarate.

Authors:  Ovidiu C Andronesi; Isabel C Arrillaga-Romany; K Ina Ly; Wolfgang Bogner; Eva M Ratai; Kara Reitz; A John Iafrate; Jorg Dietrich; Elizabeth R Gerstner; Andrew S Chi; Bruce R Rosen; Patrick Y Wen; Daniel P Cahill; Tracy T Batchelor
Journal:  Nat Commun       Date:  2018-04-16       Impact factor: 14.919

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.