| Literature DB >> 34949580 |
Stephanie Grana Van Decker1, Nicholas Bosch2, Jaime Murphy2.
Abstract
Catheter-associated urinary tract infections (CAUTIs) represent approximately 9% of all hospital acquired infections, and approximately 65%-70% of CAUTIs are believed to be preventable. In the spring of 2013, Boston Medical Center (BMC) began an initiative to decrease CAUTI rates within its intensive care units (ICUs). A CAUTI taskforce convened and reviewed process maps and gap analyses. Based on Centers for Disease Control and Prevention (CDC) and Institute for Healthcare Improvement (IHI) guidelines, and delineated by the Healthcare Infection Control Practices Advisory Committee 2009 guidelines, all BMC ICUs sequentially implemented plan-do-study-act cycles based on which measures were most easily adaptable and believed to have the highest impact on CAUTI rates. Implementation of five care bundles spanned 5 years and included (1) processes for insertion and maintenance of foley catheters; (2) indications for indwelling foley catheters; (3) appropriate testing for CAUTIs; (4) alternatives to indwelling devices; and (5) sterilisation techniques. Daily rounds by unit nursing supervisors and inclusion of foley catheter necessity on daily ICU checklists held staff accountable on a daily basis. With these interventions, the total number of CAUTIs at BMC decreased from 53 in 2013 to 9 in 2017 (83% reduction) with a 33.8% reduction in indwelling foley catheter utilisation during the same time period. Adapted protocols showed success in decreasing the CAUTI rate and indwelling foley catheter usage in all of the BMC ICU's. While all interventions had favourable and additive trends towards decreasing the CAUTI rate, the CAUTI awareness education, insertion and removal protocols and implementation of PureWick female incontinence devices had clear and significant effects on decreasing CAUTI rates. Our project provides a framework for improving HAIs using rapid cycle testing and U-chart data monitoring. Targeted education efforts and standardised checklists and protocols adapted sequentially are low-cost and high yield efforts that may decrease CAUTIs in ICU settings. © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.Entities:
Keywords: control charts/run charts; healthcare quality improvement; quality improvement; quality improvement methodologies; quality measurement
Mesh:
Year: 2021 PMID: 34949580 PMCID: PMC8705224 DOI: 10.1136/bmjoq-2021-001534
Source DB: PubMed Journal: BMJ Open Qual ISSN: 2399-6641
Figure 3Boston Medical Center (BMC) CAUTI rate per 1000 patient-days October 2013 to December 2018. U-chart depicting CAUTI rate decline in response to rapid cycle testing of CAUTI bundle with a significant decrease in rate of CAUTIs with the CAUTI awareness campaign and with the new indwelling foley catheter insertion and maintenance protocols implemented in September 2014 as well as implementation of PureWick catheter. CHG, chlorhexidine gluconate; ICU, intensive care unit; UCL, upper control limit; UTI, urinary tract infection; IP; inpatient.