Literature DB >> 34947556

Screen-Printed Electrode Surface Modification with NiCo2O4/RGO Nanocomposite for Hydroxylamine Detection.

Somayeh Tajik1, Hadi Beitollahi2, Sayed Ali Ahmadi3, Mohammad Bagher Askari4, Antonio Di Bartolomeo5.   

Abstract

We developed a novel hydroxylamine sensor through the surface modification of screen-printed electrode (SPE) with NiCo2O4 nanoparticles/reduced graphene oxide (RGO) nanocomposite (NiCo2O4/RGO/SPE). We assessed the electrochemical response of hydroxylamine on the as-fabricated sensor, confirming the high electrocatalytic impact of hydroxylamine oxidation. The electrode produced sensitively responded to hydroxylamine under optimized conditions, with a low limit of detection (2.0 nM) and broad linear dynamic range (0.007-385.0 µM). The presence of NiCo2O4 combined with the modification of RGO resulted in sensitive detection and signal amplification of hydroxylamine oxidation. The proposed sensor was used to determine the existence of hydroxylamine in water samples.

Entities:  

Keywords:  NiCo2O4/RGO nanocomposite; hydroxylamine; screen-printed electrode; voltammetry

Year:  2021        PMID: 34947556      PMCID: PMC8705719          DOI: 10.3390/nano11123208

Source DB:  PubMed          Journal:  Nanomaterials (Basel)        ISSN: 2079-4991            Impact factor:   5.076


1. Introduction

Hydroxylamine, HA or NH2OH, is an ammonium-containing agent that can act as an intermediate in microbial nitrogen cycle processes, generated during anaerobic ammonium oxidation and nitrification. It has also a function of reducing agent extensively present in various pharmaceutical and industrial applications [1]. Nevertheless, the presence of this agent may show moderate toxicity in humans, plants and animals with reversible and irreversible physiological side effects. The low concentrations (mM) of HA are reportedly found in a stable state for several hours at the pH value of 4.0 but for only 1 h at the pH value of 7.8 in exposure to air [2,3]. Accordingly, it is important to detect HA directly in environmental and biological specimens. The presence of HA has been recently detected by various techniques, including gas chromatography [4], capillary electrophoresis [5], spectrophotometric [6,7] and chromatography [8,9] analysis, although they involve complex processes. Recently, due to their low cost, operational simplicity, high sensitivity, good selectivity, and fast response, electrochemical techniques have gained attention and have exhibited promising applications for HA analysis [10,11,12,13,14,15]. Screen-printed electrodes (SPEs) are disposable electrochemical electrodes with advantages like low cost, mass production, disposability and low background current, which can improve multiple shortcomings of carbon paste electrodes and glassy carbon electrodes, such as tedious cleaning procedures and memory impacts. The practical application of disposable screen-printed electrodes is limited due to shortcomings such as low reproducibility and sensitivity, but their modifiable surface is able to improve various sensing materials in terms of detection performance [16,17,18,19]. Hence, the detection of HA can be achieved using the SPEs. Chemically modified electrodes improve mass transfer kinetics at low overpotential resulting in a decrease the interferences’ effect and avoiding surface fouling [20,21,22,23,24,25,26]. The performance of the sensors has been improved due to significant advances in nanomaterials, for example in terms of sensitivity and a wide range of detection of target molecules [27,28,29,30,31,32,33,34,35]. In the structure of the NiCo2O4 spinel, the Ni atoms occupy the tetrahedral sites, and the Co atoms occupy the octahedral sites in Co3O4. NiCo2O4, with low activation energy of electron transfer between cations, exhibits better conductivity and electrochemical features compared to pure Co3O4 and NiO. Several deficiencies have been reported for NiCo2O4, including low conductivity and easy accumulation on the electrode surface, hence resulting in poor sensitivity [36,37,38]. We can enhance the electrical conductivity and widen the surface area through the combination of composite materials. Graphene has been recently at the center of attention because of special chemical, optical and electronic properties. In particular, reduced graphene oxide (RGO) has been evaluated and applied in different fields. In electrochemistry, owing to the large surface area, high conductivity and admirable electrochemical responses, RGO has been used to load of other nanomaterials. Composites provide synergistic impacts, which are highly desired in sensor surface modification. The integration of NiCo2O4 and graphene can significantly prevent the self-accumulation of individual graphene and metal oxides. The RGO with large surface area and potent electrical conductivity forms further active sites for NiCo2O4, thereby enhancing the sensing potential of NiCo2O4 [39,40,41]. The novelty of this work concerns the observed catalytic action of the NiCo2O4/RGO nanocomposite, demonstrating the possibility to detect HA at a low potential and at higher current values. Moreover, the NiCo2O4/RGO/SPE sensor was applied to detect the HA in the different water samples.

2. Materials and Methods

2.1. Chemicals and Equipment

The electrochemical measurements were performed by a PGSTAT 302N Autolab potentiostat/galvanostat analyzer (Eco-Chemie; B.V. Kanaalweg, The Netherlands). All test conditions were monitored by General Purpose Electrochemical System (GPES) software. A three-part DropSens SPE (DRP-110, Asturias, Spain) included a graphite working electrode, a silver pseudo-reference electrode and a graphite auxiliary electrode. The solution pH values were measured by a Metrohm 710 pH meter. Double distilled water was applied to prepare all test fresh solutions. All reagents, including hydroxylamine, possessed analytical grade belonged to Merck (Darmstadt, Germany). Orthophosphoric acid and related salts were utilized to prepare all buffer solutions at the pH values (2.0 to 9.0).

2.2. Fabrication of NiCo2O4/RGO Nanocomposite

A modified Hummers method was used to construct the graphene oxide. To this end, the graphite powder (1 g) was first poured into sulfuric acid (200 mL) and stirred for 1 h, followed by placing in the cold-water bath and gradually adding KMnO4 (9 g) and stirring for 24 h. Then, the obtained mixture was added slowly with deionized water (200 mL) and subsequently with H2O2 (35 mL) to stop the oxidation. Next, the product (GO) was exposed to 0.2 M HCl and rinsed by deionized water to discard additional acid. The NiCo2O4 nanorods were produced by dissolving cobalt acetate.4H2O (2 mM) and Nickel acetate.4H2O (1 mM) in a mixture of deionized water and ethylene glycol (in equal ratios) under the ultrasonication. Then, the mixture was gradually added with polyvinylpyrrolidone (10 mM PVP), stirred for one hour, placed in a Teflon autoclave, and dried in an oven for 16 h at 160 °C. The obtained product was washed by distilled water and ethanol, dried for 24 h at a temperature of 60 °C, and finally calcined at 400 °C for 2 h. The NiCo2O4/RGO was constructed by dissolving GO (100 mg) into a mixture of deionized water and ethylene glycol (with equal ratio), followed by adding the PVP (10 mM) and stirring for 1 h and subsequently adding Co(Ac)2·4H2O (2 mM) and Ni(Ac)2·4H2O (1 mM) and re-stirring for 2 h. The reaction mixture was placed in the steel autoclave, dried in the oven at 160 °C for 16 h, washed with distilled water-ethanol mix, re-dried at 60 °C for 24 h, and finally calcined at 400 °C for 2 h to collect spinel NiCo2O4/RGO. The RGO:NiCo2O4 weight ratio was approximately 1:2.

2.3. Fabrication of Modified Electrode

A facile protocol was performed to cover the bare SPE using the NiCo2O4/RGO nanocomposite. Thus, 1 mg of NiCo2O4/RGO nanocomposite was dispersed in 1 mL aqueous solution and ultra-sonicated for half an hour to give a homogeneous solution. Then, 4 µL of prepared suspension was dropped on the surface of SPE surface. After the solvent evaporated, the electrode surface was thoroughly rinsed with deionized water to wash away the unremoved modifier and dried at room temperature. The obtained electrode was noted as NiCo2O4/RGO/SPE. In order to investigate the available active surface area of electrodes, the cyclic voltammograms bare SPE and NiCo2O4/RGO/SPE were recorded in 1 mM K3Fe(CN)6 at different scan rates. Using the Randles–Sevcik equation [42], the electrochemical active surface area of NiCo2O4/RGO/SPE was found 0.01 cm2 which was about 3.2 times greater than bare SPGE.

2.4. Real Sample Analysis

The real specimens included river, drinking and tap water samples, which were filtered thoroughly before analysis and then different amounts of HA concentrations were added to the samples and analyzed using standard addition method.

3. Results

3.1. Determination of the NiCo2O4/RGO Nanocomposite Characteristics

The XRD method was used to evaluate NiCo2O4/RGO and NiCo2O4 for crystal structure. Figure 1 shows the 2θ angles of XRD peaks and corresponding planes, in line with the previous findings and JCPDS (20-078).
Figure 1

X-ray diffraction (XRD) spectra recorded for fabricated graphene oxide (GO), reduced GO (RGO) and NiCo2O4/RGO.

The 2θ values of 64.86°, 59.16°, 55.28°, 44.54°, 38.48°, 36.61° and 31.09° were related to the cubic NiCo2O4 phase planes of (440), (511), (422), (400), (222), (311) and (220) in line with JCPDS [20-0781] and previous findings. The wide peak (2θ = 25°) corresponded to RGO. GO has a relatively wide characteristic peak at 2θ about 10°, which indicates the graphite was fully oxidized into GO. The mean crystallite size of NiCo2O4/RGO was calculated to be 70 nm in accordance with the Debye–Scherrer equation. The Raman spectra recorded for fabricated materials are shown in Figure 2. The wide peaks at 1583 and 1330 cm−1 were related to NiCo2O4/RGO and RGO, corresponding to G and D bands, respectively. The peak of Raman G band was related to in-plane movement of sp2 carbons, and the Raman D band peak to sp3 (out-of-plane vibrations).
Figure 2

Raman spectra recorded for NiCo2O4/RGO and RGO.

The D/G ratio is higher in the composite RGO than in the pure RGO. The elevated D/G ratio means the RGO hybridization with NiCo2O4, enhancing the defect density in RGO and defect in carbon layers. The peaks of Ni–O and Co–O vibrations at 654, 501, 456 and 181 cm−1 were, respectively, related to A1g, F2g, Eg and F2g of phonon types of NiCo2O4. To study the surface morphology and also to prove the presence of hybrid constituent elements, scanning electron microscope (SEM) images and energy-dispersive X-ray analysis (EDX) mapping were prepared. Figure 3a shows NiCo2O4 nanoparticles. The average size of these nanorods is about 40 nm, and in this figure, a uniform rod-shaped morphology can be seen. RGO nanosheets are also shown in Figure 3b. The plate morphology of these two-dimensional materials is also clearly shown in this image. In the case of hybrids used in electrochemical processes, one of the most important parameters is the uniform dispersion of nanomaterials on a substrate. Figure 3c clearly shows the uniform distribution of NiCo2O4 nanorods on the surface of RGO. The presence of nano-hybrid constituents, including nickel, cobalt, oxygen, and carbon was confirmed by the EDX mapping analysis (Figure 3d).
Figure 3

The scanning electron microscopy (SEM) images taken from (a) NiCo2O4 nanorod, (b) RGO nanosheets, (c) NiCo2O4/RGO and (d) The energy-dispersive X-ray analysis (EDX) mapping of NiCo2O4/RGO.

3.2. Electrochemical Responses of Hydroxylamine on the Surface of NiCo2O4/Reduced Graphene Oxide (RGO)/Screen-Printed Electrode (SPE)

The solution pH values influence the electrochemical responses of HA, highlighting the necessity for optimizing the solution pH to determine the electrocatalytic HA oxidation, which was evaluated in 0.1 M PBS at various pH values (2.0 to 9.0) on the NiCo2O4/RGO/SPE surface using cyclic voltammetry. The results suggested neutral pH value to achieve the best outcomes of HA electrooxidation on the NiCo2O4/RGO/SPE surface. Hence, the optimal pH value was selected to be 7.0 for this purpose in the next testing. Figure 4 (curves a and b) shows the cyclic voltammograms (CVs) recorded for electrooxidation of HA (100.0 μM) on the surfaces of bare SPE and NiCo2O4/RGO/SPE. The findings from the CVs confirmed the best HA oxidation on the NiCo2O4/RGO/SPE surface at 750 mV, about 250 mV more negative than that on the bare SPE, underlining a significant improvement of HA oxidation signal via the NiCo2O4/RGO nanocomposite.
Figure 4

Cyclic voltammograms (CVs) of bare screen-printed electrode (SPE) (a) and NiCo2O4/RGO/SPE (b) in the presence of 0.1 M phosphate-buffered saline (PBS) at the pH value of 7.0 for detection of HA (100.0 μM) at the scan rate of 50 mV/s.

3.3. Results of Scan Rate Impact

Figure 5 shows the scan rate impact on the HA oxidation current, the results of which indicated an increase in the peak current with increasing scan rate. The oxidation process followed the diffusion-limited reactions obtained from the linear dependence of the anodic peak current (Ip) on the square root of the scan rate (ν1/2, 10–400 mV/s).
Figure 5

LSVs of NiCo2O4/RGO/SPE in the presence of 0.1 M PBS at the pH value of 7.0 for detection of HA (150.0 μM) at different scan rates, indicating numbers 1–7 as 10, 20, 60, 100, 200, 300 and 400 mV/s. Inset: anodic peak current variation versus ν1/2.

3.4. Chronoamperometric Measurements

Chronoamperometry was employed to evaluate the catalytic HA oxidation on the modified electrode surface in the presence of different HA concentrations on the working electrode set at the potential value of 800 mV. The HA diffusion coefficient was also determined. According to previous findings, the electrochemical current of HA under the mass transport-limited condition could be calculated using the Cottrell method:I = nFAD In this equation, D and Cb stand for diffusion coefficient (cm2/s) and bulk concentration (mol/cm3), respectively. Figure 6A shows the plot of I versus t−1/2 on the basis of experiments for various HA specimens. Figure 6B displays the slope of straight line versus HA content. The D value for HA was calculated to be 2.2 × 10−5 cm2/s based on the Cottrell equation and the slopes obtained.
Figure 6

Chronoamperograms for NiCo2O4/RGO/SPE in the presence of 0.1 M PBS at the pH value of 7.0 for detection of HA at different concentrations, indicating numbers 1−8 as 0.1, 0.25, 0.65, 0.95, 1.4, 1.9, 2.2 and 2.5 mM of HA. Insets: (A) Cottrell plot for chronoamperogram findings, (B) slope of the plot of straight lines versus HA content.

3.5. Calibration Curve and Limit of Detection

The peak currents of HA electro-oxidation on the NiCo2O4/RGO/SPE surface were used for the HA detection. Because hypersensitivity and appropriate analytical features are the advantages of differential pulse voltammetry (DPV), different HA concentrations in the NiCo2O4/RGO/SPE and PBS (0.1 M) were used for DPV analysis as shown in Figure 7 (response time = 6 s). The peak currents of HA oxidation on the surface of NiCo2O4/RGO/SPE depends linearly on HA concentrations (0.007 to 385.0 μM). The linear equation was as y = 0.0805 x + 0.9398, the correlation coefficient was estimated at 0.9999, but the limit of detection (3σ) was estimated at 2.0 nM. The LOD and linear range of HA at the NiCo2O4/RGO/SPE electrode presented in this work were compared with the reported modified electrodes and were given in Table 1.
Figure 7

DPVs of NiCo2O4/RGO/SPE in the presence of 0.1 M PBS at the pH value of 7.0 for detection of hydroxylamine (HA) at different concentrations, indicating numbers 1–11 as 0.007, 0.1, 1.0, 7.5, 15.0, 30.0, 70.0, 100.0, 200.0, 300.0 and 385.0 µM of HA. Inset: plot of peak current as a function of different HA concentrations (0.007–385.0 µM).

Table 1

Comparison of the efficiency of the NiCo2O4/RGO/SPE electrode with literature modified electrodes for HA determination.

Electrochemical SensorElectrochemical MethodLinear RangeLimit of DetectionRef.
Fullerene-functionalized carbon nanotubes/ionic liquid nanocomposite/glassy carbon electrodeDPV1.0–300.0 μM28 ± 2 nM[10]
Graphene oxidde/TiO2/SPEDPV0.1–300 μM0.065 µM[11]
Gold nanoparticles/cetyltrimethyl ammonium bromide/graphene oxide/glassy carbon electrodeAmperometry10–1000 μM3.5 μM[12]
Prussian blue-multi-walled carbon nanotubes/glassy carbon electrodeAmperometry1.5 µM–2.0 mM-[13]
Gold nanoparticles—polypyrrole nanowire/glassy carbon electrodeDPV1–500 μM0.21 μM[14]
1-benzyl-4-ferrocenyl-1H-[1,2,3]-triazole/carbon nanotube/glassy carbon electrodeSquare wave voltammetry4.0  ×  10−76.75  ×  10−4 M28.0  ±  1.0 nM[15]
NiCo2O4/RGO/SPEDPV0.007–385.0 μM2.0 nMThis Work

3.6. Interference Study

The impact of numerous interference substances on the detection of HA was investigated. The tolerance limit was taken as the maximum of the foreign materials concentration that resulted in about ±5% relative error in the detection. The results indicated that glucose, lactose, sucrose, urea, sulfite, hydrazine, phenol, thiosulphate, bisphenol A, Mg2+, Ni2+, K+, Li+, Mn2+, Cr2+, Zn2+, CN-, Br−, and SCN− did not show interference in the determination of HA.

3.7. Real Sample Analysis

The fabricated NiCo2O4/RGO/SPE was used for the detection of HA present in varied water specimens using the method of standard additions. The HA concentration and recovery rate are shown in Table 2. An excellent recovery rate was found for the HA, and mean relative standard deviation (RSD%) confirmed the reproducibility. The applicability of NiCo2O4/RGO/SPE sensor was confirmed by sensitive detection of HA concentrations in drinking, tap and river water specimens.
Table 2

Recoveries for detection of hydroxylamine in water specimens (n = 5).

SampleSpikedFound Recovery (%)R.S.D. (%)
Drinking water0---
5.04.998.03.2
7.07.3104.32.7
9.09.1101.11.9
11.010.999.12.4
Tap water0---
4.54.6102.22.9
6.56.397.03.5
8.58.498.81.6
10.510.6100.92.5
River water0---
5.55.498.22.7
7.57.8104.02.1
9.59.6101.03.6
11.511.499.12.0

4. Conclusions

In this work, we prepared NiCo2O4/RGO nanocomposite by a simple method. The successful preparation of this nanocomposite was revealed by FESEM, EDX mapping, XRD, and Raman spectroscopy. Then, we developed a novel voltammetric hydroxylamine sensor through the surface modification of SPE with NiCo2O4/RGO nanocomposite as a signal amplifier for HA detection. The oxidation peak currents of HA presented a good linear relationship with the concentrations in the range from 0.007 to 385.0 μM with a detection limit of 2.0 nM. Moreover, the detection of HA in water samples by the proposed sensor showed satisfactory results.
  13 in total

1.  A simple and sensitive method for the determination of hydroxylamine in fresh-water samples using hypochlorite followed by gas chromatography.

Authors:  Yasushi Seike; Ryoko Fukumori; Yukiko Senga; Hiroki Oka; Kaoru Fujinaga; Minoru Okumura
Journal:  Anal Sci       Date:  2004-01       Impact factor: 2.081

2.  A high sensitive biosensor based on FePt/CNTs nanocomposite/N-(4-hydroxyphenyl)-3,5-dinitrobenzamide modified carbon paste electrode for simultaneous determination of glutathione and piroxicam.

Authors:  Hassan Karimi-Maleh; Fahimeh Tahernejad-Javazmi; Ali A Ensafi; Reza Moradi; Shadpour Mallakpour; Hadi Beitollahi
Journal:  Biosens Bioelectron       Date:  2014-04-02       Impact factor: 10.618

3.  Rapid synthesis of rGO conjugated hierarchical NiCo2O4 hollow mesoporous nanospheres with enhanced glucose sensitivity.

Authors:  Bingrong Wang; Yang Cao; Yong Chen; Xiaoyong Lai; Juan Peng; Jinchun Tu; Xiaotian Li
Journal:  Nanotechnology       Date:  2016-12-01       Impact factor: 3.874

4.  Rapid determination of acetone in human blood by derivatization with pentafluorobenzyl hydroxylamine followed by headspace liquid-phase microextraction and gas chromatography/mass spectrometry.

Authors:  Chunhui Deng; Ning Li; Xiaochuan Wang; Xiangmin Zhang; Jia Zeng
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

5.  Cyanazine herbicide monitoring as a hazardous substance by a DNA nanostructure biosensor.

Authors:  Hassan Karimi-Maleh; Fatemeh Karimi; Li Fu; Afsaneh L Sanati; Marzieh Alizadeh; Ceren Karaman; Yasin Orooji
Journal:  J Hazard Mater       Date:  2021-08-28       Impact factor: 10.588

6.  Ion chromatographic determination of trace hydroxylamine in waste streams generated by a pharmaceutical reaction process.

Authors:  Peter N Fernando; Ignatius N Egwu; Mumtaz S Hussain
Journal:  J Chromatogr A       Date:  2002-05-17       Impact factor: 4.759

7.  Ultrasensitive Detection of Bacteria Using a 2D MOF Nanozyme-Amplified Electrochemical Detector.

Authors:  Wen-Chao Hu; Jie Pang; Sudip Biswas; Kang Wang; Chen Wang; Xing-Hua Xia
Journal:  Anal Chem       Date:  2021-06-07       Impact factor: 6.986

8.  A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode.

Authors:  Onur Can Bodur; Saliha Dinç; Mustafa Özmen; Fatma Arslan
Journal:  Biotechnol Appl Biochem       Date:  2020-02-17       Impact factor: 2.431

Review 9.  Recent advances in ZnO nanostructure-based electrochemical sensors and biosensors.

Authors:  Hadi Beitollahi; Somayeh Tajik; Fariba Garkani Nejad; Mohadeseh Safaei
Journal:  J Mater Chem B       Date:  2020-07-15       Impact factor: 6.331

10.  Simultaneous and selective electrochemical sensing of methotrexate and folic acid in biological fluids and pharmaceutical samples using Fe3O4/ppy/Pd nanocomposite modified screen printed graphite electrode.

Authors:  Somayeh Tajik; Hadi Beitollahi; Saeed Shahsavari; Fariba Garkani Nejad
Journal:  Chemosphere       Date:  2021-10-30       Impact factor: 7.086

View more
  5 in total

1.  Application of MnO2 Nanorod-Ionic Liquid Modified Carbon Paste Electrode for the Voltammetric Determination of Sulfanilamide.

Authors:  Hadi Beitollahi; Somayeh Tajik; Antonio Di Bartolomeo
Journal:  Micromachines (Basel)       Date:  2022-04-10       Impact factor: 3.523

2.  The Facile Preparation of PBA-GO-CuO-Modified Electrochemical Biosensor Used for the Measurement of α-Amylase Inhibitors' Activity.

Authors:  Min Li; Xiaoying Yin; Hongli Shan; Chenting Meng; Shengxue Chen; Yinan Yan
Journal:  Molecules       Date:  2022-04-07       Impact factor: 4.927

Review 3.  Towards Development of Molecularly Imprinted Electrochemical Sensors for Food and Drug Safety: Progress and Trends.

Authors:  Shuhong Zhou; Chen Liu; Jianguo Lin; Zhi Zhu; Bing Hu; Long Wu
Journal:  Biosensors (Basel)       Date:  2022-05-27

4.  Determination of Paracetamol on Electrochemically Reduced Graphene Oxide-Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry.

Authors:  Zandile D Leve; Nazeem Jahed; Nelia A Sanga; Emmanuel I Iwuoha; Keagan Pokpas
Journal:  Sensors (Basel)       Date:  2022-08-03       Impact factor: 3.847

5.  Voltammetric Determination of Isoniazid in the Presence of Acetaminophen Utilizing MoS2-Nanosheet-Modified Screen-Printed Electrode.

Authors:  Somayeh Tajik; Zahra Dourandish; Fariba Garkani Nejad; Abbas Aghaei Afshar; Hadi Beitollahi
Journal:  Micromachines (Basel)       Date:  2022-02-26       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.