Literature DB >> 3493276

Quantitation in positron emission tomography: 8. Effects of nonlinear parameter estimation on functional images.

S C Huang, D K Mahoney, M E Phelps.   

Abstract

Functional images used in positron emission tomography (PET) have the advantage of presenting simultaneously the anatomical and functional information in cross-sectional body slices. However, the nonlinearity in parameter estimation, when combined with the finite image resolution, can cause systematic errors or biases in the estimated functional parameters. The effect of this error on blood flow images, which are commonly used in PET, is investigated in this study. Computer-simulated brain and heart phantoms of realistic configurations are used to examine the effect of various factors, such as imaging resolution, estimation nonlinearity, and structure configuration. The nonlinearity characteristics of six commonly used blood flow estimation techniques are simulated. Results show that structure boundaries on parametric images between tissues of different blood flows do not usually coincide with the true anatomical boundaries and would thus cause an apparent change in the cross-sectional size of the structures. The regional blood flow values as obtained from the blood flow images are usually lower than the true values. The severity of these effects is dependent on the characteristics of the flow estimation technique, the image resolution, and the size and shape of the structure. Although image resolution is a major factor in causing errors in the parametric images, its improvement, within the range examined in the present study [from 1.5 to 0.5 cm full width at half maximum (FWHM)], is not found to reduce drastically the underestimation of blood flow in brain phantom. The effect on boundary shift, however, is found to be in proportion to the FWHM of image resolution. Implications of these effects on generation, interpretation, and comparison of parametric/functional images are discussed.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3493276

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  7 in total

1.  Error analysis of autoradiography method for measurement of cerebral blood flow by 123I-IMP brain SPECT: a comparison study with table look-up method and microsphere model method.

Authors:  H Ito; K Ishii; H Atsumi; Y Inukai; S Abe; M Sato; T Kinoshita; R Kawashima; S Ono; H Fukuda
Journal:  Ann Nucl Med       Date:  1995-11       Impact factor: 2.668

2.  Preserved acetazolamide reactivity in lacunar patients with severe white-matter lesions: 15O-labeled gas and H2O positron emission tomography studies.

Authors:  Tomohisa Nezu; Chiaki Yokota; Toshiyuki Uehara; Miho Yamauchi; Kazuhito Fukushima; Kazunori Toyoda; Masayasu Matsumoto; Hidehiro Iida; Kazuo Minematsu
Journal:  J Cereb Blood Flow Metab       Date:  2012-01-18       Impact factor: 6.200

3.  A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling.

Authors:  H Iida; H Itoh; P M Bloomfield; M Munaka; S Higano; M Murakami; A Inugami; S Eberl; Y Aizawa; I Kanno
Journal:  Eur J Nucl Med       Date:  1994-10

4.  Error analysis of table look-up method for cerebral blood flow measurement by 123I-IMP brain SPECT: comparison with conventional microsphere model method.

Authors:  H Ito; K Ishii; H Atsumi; T Kinoshita; R Kawashima; S Ono; S Yoshioka; H Iida; K Uemura; H Fukuda
Journal:  Ann Nucl Med       Date:  1995-05       Impact factor: 2.668

5.  Application of carbon-11 labelled nicotine in the measurement of human cerebral blood flow and other physiological parameters.

Authors:  F Yokoi; T Komiyama; T Ito; T Hayashi; M Lio; T Hara
Journal:  Eur J Nucl Med       Date:  1993-01

Review 6.  What scans we will read: imaging instrumentation trends in clinical oncology.

Authors:  Thomas Beyer; Luc Bidaut; John Dickson; Marc Kachelriess; Fabian Kiessling; Rainer Leitgeb; Jingfei Ma; Lalith Kumar Shiyam Sundar; Benjamin Theek; Osama Mawlawi
Journal:  Cancer Imaging       Date:  2020-06-09       Impact factor: 3.909

7.  F-18 fluorodeoxyglucose uptake and water-perfusable tissue fraction in assessment of myocardial viability.

Authors:  Hidehiro Iida; Ulla Ruotsalainen; Maija Mäki; Merja Haaparnata; Jörgen Bergman; Liisa-Maria Voipio-Pulkki; Pirjo Nuutila; Kazuhiro Koshino; Juhani Knuuti
Journal:  Ann Nucl Med       Date:  2012-07-15       Impact factor: 2.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.