| Literature DB >> 34926498 |
Yuan Zhang1, Hongbin Hu1, Qing Zhang2, Qing Ou1, Huayou Zhou3, Tong Sha1, Zhenhua Zeng1, Jie Wu1, Jingrui Lu4, Zhongqing Chen1.
Abstract
Objectives: Our ex vivo study was designed to determine the sequestration of teicoplanin, tigecycline, micafungin, meropenem, polymyxin B, caspofungin, cefoperazone sulbactam, and voriconazole in extracorporeal membrane oxygenation (ECMO) circuits.Entities:
Keywords: antimicrobial agents; ex vivo; extracorporeal membrane oxygenation; intensive care unit; sequestration
Year: 2021 PMID: 34926498 PMCID: PMC8671752 DOI: 10.3389/fmed.2021.748769
Source DB: PubMed Journal: Front Med (Lausanne) ISSN: 2296-858X
Figure 1Simulated closed loop ECMO circuits primed with fresh whole human blood. (A) Ex vivo ECMO circuit. A reservoir bag containing 30 mL of blood was used to construct a bypass to maintain the pressure of the circuit. A total of 800 mL of fresh whole human blood (<1 h) was used to prime the circuit. (B) In vivo ECMO circuit.
Figure 2Durg recovery of experimental drugs at different time points in Sorin and Maquet ECMO circuits and corresponding control groups. Average drug recovery vs. time for (A) teicoplanin, (B) tigecycline, (C) micafungin, (D) meropenem, (E) polymyxin B, (F) caspofungin, (G) cefoperazone, (H) sulbactam, and (I) voriconazole in the Maquet (blue) and Sorin (red) circuits and corresponding control groups.
The log P-value and protein-binding rate of drugs and the extent of their loss in the blood-primed circuit at 24 h.
|
|
|
|
|
|
|---|---|---|---|---|
| Teicoplanin | 66.64 (24.37) | 89.06 (14.40) | −1.1 | 90–95 |
| Tigecycline | 100.03 (13.68) | 144.54 (2.31) | 0.8 | 71–89 |
| Micafungin | 66.85 (-) | 98.82 (-) | −1.5 | 99 |
| Meropenem | 45.37 (3.58) | 74.84 (19.10) | −0.6 | 2 |
| Polymyxin B | 61.66 (-) | 60.10 (-) | −4.861 | 79–92 |
| Caspofungin | 83.26 (6.17) | 85.24 (7.93) | −2.798 | 97 |
| Cefoperazone | 79.41 (19.16) | 98.30 (1.17) | −0.74 | 82–93 |
| Sulbactam | 75.15 (6.50) | 86.55 (11.31) | −0.92 | 38 |
| Voriconazole | 59.70 (16.00) | 101.01 (2.85) | 2.561 | 58 |
Data are presented as the mean (SD).
he data of polymyxin B data were only available in the Sorin circuit; therefore, they had no standard deviation.
og P and protein-binding rate for the individual drugs were obtained from DrugBank.