Literature DB >> 3492571

Lack of comparability between commonly used serological assays of immune response to Haemophilus influenzae vaccine.

K M Edwards, M D Decker, P Palmer, C R Porch, S H Sell, P F Wright.   

Abstract

Reliable measures of the serum level of antibody to the capsular polysaccharide (PRP) of Haemophilus influenzae type b (Hib) are essential for evaluating current and future vaccines intended to protect against invasive disease. It was recently noted, however, that certain commonly used assays of antibody to PRP produced incompatible results. To investigate this observation, we analyzed banked sera from four PRP vaccine studies in parallel by several assays. Significant differences were noted, both in absolute titers and in the ratios of post- to prevaccination titers, between the various assays. These differences seemed to be due to the different antigen preparations used in the assays. Unless workers standardize on a single assay, protective levels of antibody to PRP will have to be defined separately for each assay. Serological results of Hib vaccine trials cannot be compared without considering the assay methods used.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3492571     DOI: 10.1093/infdis/155.2.283

Source DB:  PubMed          Journal:  J Infect Dis        ISSN: 0022-1899            Impact factor:   5.226


  5 in total

1.  Interlaboratory study evaluating quantitation of antibodies to Haemophilus influenzae type b polysaccharide by enzyme-linked immunosorbent assay.

Authors:  D V Madore; P Anderson; B D Baxter; G M Carlone; K M Edwards; R G Hamilton; P Holder; H Käyhty; D C Phipps; C C Peeters; R Schneerson; G R Siber; J I Ward; C E Frasch
Journal:  Clin Diagn Lab Immunol       Date:  1996-01

2.  Relationship of health-related variables to levels of anti-polyribosylribitol phosphate antibodies in adults.

Authors:  W M McDonnell; J R Gilsdorf; J B Kent; J N Sheagren
Journal:  J Clin Microbiol       Date:  1988-06       Impact factor: 5.948

3.  Protection of infant rats from Haemophilus influenzae type b infection by antiserum to purified outer membrane protein a.

Authors:  M R Loeb
Journal:  Infect Immun       Date:  1987-11       Impact factor: 3.441

4.  Comparison between radioimmunoassay and direct and indirect enzyme-linked immunosorbent assays for determination of antibodies against Haemophilus influenzae type b capsular polysaccharide.

Authors:  T Lagergård; B Trollfors; B A Claesson; R Schneerson; J B Robbins
Journal:  J Clin Microbiol       Date:  1988-12       Impact factor: 5.948

5.  Variable quantitation of Haemophilus influenzae type b anticapsular antibody by radioantigen binding assay.

Authors:  J I Ward; D P Greenberg; P W Anderson; K S Burkart; P D Christenson; L K Gordon; H Kayhty; J S Kuo; P Vella
Journal:  J Clin Microbiol       Date:  1988-01       Impact factor: 5.948

  5 in total