Literature DB >> 3230133

Comparison between radioimmunoassay and direct and indirect enzyme-linked immunosorbent assays for determination of antibodies against Haemophilus influenzae type b capsular polysaccharide.

T Lagergård1, B Trollfors, B A Claesson, R Schneerson, J B Robbins.   

Abstract

Levels of antibodies against Haemophilus influenzae type b capsular polysaccharide were determined in acute-phase and convalescent-phase serum samples obtained from 21 children with invasive H. influenzae type b infections and from 44 children vaccinated with two H. influenzae type b vaccines. Amounts of immunoglobulin G (IgG), IgM, and IgA antibodies were measured by direct and indirect enzyme-linked immunosorbent assay (ELISA), and the total amount of antibodies was measured by radioimmunoassay (RIA). Results obtained by ELISA were calculated by multiple-point parallel-line comparison and by endpoint analysis. A very good correlation was obtained between direct and indirect ELISA values. In the lower range of antibody concentrations, the correlation between ELISA values obtained by endpoint analysis and those obtained by multiple-point parallel-line comparison was poor, since the latter method of calculation yielded values of up to 1 microgram/ml in sera that were negative according to endpoint analysis. These sera with negative endpoint titers also had undetectable or very low antibody concentrations as measured by RIA. Consistent with this finding, in acute-phase and prevaccination sera with undetectable or low antibody concentrations as measured by RIA, ELISA values calculated by multiple-point parallel-line comparison were much higher. In sera with higher antibody concentrations, however, parallel-line comparisons showed good correlation between RIA and ELISA values. Although no reference method for measuring true antibody concentrations is available, ELISA values as calculated by multiple-point parallel-line comparison appear to overestimate antibody concentrations in sera containing low antibody concentrations, whereas ELISA values obtained by endpoint analysis are less well correlated with RIA values at higher concentrations.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3230133      PMCID: PMC266944          DOI: 10.1128/jcm.26.12.2554-2557.1988

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  15 in total

1.  Clinical and immunologic responses to the capsular polysaccharide of Haemophilus influenzae type b alone or conjugated to tetanus toxoid in 18- to 23-month-old children.

Authors:  B A Claesson; B Trollfors; T Lagergard; J Taranger; D Bryla; G Otterman; T Cramton; Y Yang; C B Reimer; J B Robbins
Journal:  J Pediatr       Date:  1988-05       Impact factor: 4.406

2.  Quantitative measurement of "natural" and immunization-induced Haemophilus influenzae type b capsular polysaccharide antibodies.

Authors:  J B Robbins; J C Parke; R Schneerson; J K Whisnant
Journal:  Pediatr Res       Date:  1973-03       Impact factor: 3.756

3.  Immunization of 2-month-old infants with protein-coupled oligosaccharides derived from the capsule of Haemophilus influenzae type b.

Authors:  P Anderson; M E Pichichero; R A Insel
Journal:  J Pediatr       Date:  1985-09       Impact factor: 4.406

4.  The protective level of serum antibodies to the capsular polysaccharide of Haemophilus influenzae type b.

Authors:  H Käyhty; H Peltola; V Karanko; P H Mäkelä
Journal:  J Infect Dis       Date:  1983-06       Impact factor: 5.226

5.  Intrinsic tritium labeling of the capsular polysaccharide antigen of Haemophilus influenzae type B.

Authors:  P Anderson
Journal:  J Immunol       Date:  1978-03       Impact factor: 5.422

6.  A radioactive antigen-binding assay for the measurement of antibody to Haemophilus influenzae type b capsular polysaccharide.

Authors:  J S Kuo; N Monji; R S Schwalbe; D W McCoy
Journal:  J Immunol Methods       Date:  1981       Impact factor: 2.303

7.  An avidin-biotin based ELISA for quantitation of antibody to bacterial polysaccharides.

Authors:  A Sutton; W F Vann; A B Karpas; K E Stein; R Schneerson
Journal:  J Immunol Methods       Date:  1985-10-10       Impact factor: 2.303

8.  Quantitative and qualitative analyses of serum antibodies elicited in adults by Haemophilus influenzae type b and pneumococcus type 6A capsular polysaccharide-tetanus toxoid conjugates.

Authors:  R Schneerson; J B Robbins; J C Parke; C Bell; J J Schlesselman; A Sutton; Z Wang; G Schiffman; A Karpas; J Shiloach
Journal:  Infect Immun       Date:  1986-05       Impact factor: 3.441

9.  Enzyme-linked immunosorbent assay for detection of capsular antibodies against Haemophilus influenzae type b: comparison with radioimmunoassay.

Authors:  S L Kaplan; E O Mason; G Johnson; R A Broughton; D Hurley; J C Parke
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

10.  Quantitation of antibodies to Haemophilus influenzae type b in humans by enzyme-linked immunosorbent assay.

Authors:  T Dahlberg
Journal:  J Clin Microbiol       Date:  1981-06       Impact factor: 5.948

View more
  4 in total

1.  Correlations between antibody immune responses at different mucosal effector sites are controlled by antigen type and dosage.

Authors:  D Externest; B Meckelein; M A Schmidt; A Frey
Journal:  Infect Immun       Date:  2000-07       Impact factor: 3.441

2.  Optimization and standardization of an enzyme-linked immunosorbent assay protocol for serodiagnosis of Actinobacillus pleuropneumoniae serotype 5.

Authors:  Y L Trottier; P F Wright; S Larivière
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

3.  Isotype composition of antibodies to streptococcus group B type III polysaccharide and to tetanus toxoid in maternal, cord blood sera and in breast milk.

Authors:  T Lagergård; K Thiringer; L Wassén; R Schneerson; B Trollfors
Journal:  Eur J Pediatr       Date:  1992-02       Impact factor: 3.183

4.  Multicenter comparison of Neisseria meningitidis serogroup C anti-capsular polysaccharide antibody levels measured by a standardized enzyme-linked immunosorbent assay.

Authors:  L L Gheesling; G M Carlone; L B Pais; P F Holder; S E Maslanka; B D Plikaytis; M Achtman; P Densen; C E Frasch; H Käyhty
Journal:  J Clin Microbiol       Date:  1994-06       Impact factor: 5.948

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.