| Literature DB >> 34909570 |
Ciara Mahon1, Raad H Mohiaddin1,2.
Abstract
Entities:
Year: 2021 PMID: 34909570 PMCID: PMC8664754 DOI: 10.1093/ehjcr/ytab438
Source DB: PubMed Journal: Eur Heart J Case Rep ISSN: 2514-2119
Non-invasive imaging modalities used for the selection of anatomically suitable patients for transcatheter aortic valve implantation in contemporary practice
| TTE/TOE | MSCT | CMR | |
|---|---|---|---|
| AV stenosis (gradient and valve area) | +++ | + | +++ |
| AV regurgitation and paravalvular leak | ++ | — | +++ |
| AV morphology (bicuspid vs. tricuspid) | ++ | +++ | +++ |
| AV annulus dimensions and perimeter | ++ | +++ | +++ |
| Aortic root and ascending aorta dimensions | ++ | +++ | +++ |
| Coronary height | ± | +++ | +++ |
| Coronary artery disease severity/ischaemia assessment | ++ | +++ | +++ |
| TAVI vascular access | — | ++ | +++ |
| Calcification (valve and vascular) | ++ | +++ | + |
| Assessment of LV function and other valves | +++ | + | +++ |
| Myocardial structure (infarct/fibrosis/amyloid infiltration) | + | — | +++ |
| Patients with renal impairment (contrast nephrotoxicity) | +++ | ± | ++ |
| Patients at high risk of radiation exposure | +++ | ± | +++ |
| Patients with PPM, ICD and other implantable devices | +++ | +++ | ± |
| Availability and ease of use | +++/+ | ++ | + |
| Cost consideration | +++/++ | ++ | ++ |
+++ high suitability, ++ moderate suitability, + low suitability and — unsuitable.
AV, aortic valve; CMR, cardiovascular magnetic resonance; ICD, implantable cardioverter-defibrillator; LV, left ventricle; MSCT, multi-slice computed tomography; PPM, permanent pacemaker; TAVI, transcatheter aortic valve insertion; TOE, transoesophageal echocardiography; TTE, transthoracic echocardiography