Mohammad Sadeghian1, Vahid Mohammadi1, Akbar Shafiee2, Hamidreza Babakhani3. 1. MD, Department of Cardiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran. 2. MD, Department of Cardiovascular Research, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran. 3. MSc, Department of Mechanical Engineering, Tarbiat Modarres University, Tehran, Iran.
The aggregation of lipid deposits leads to stenosis and flow disturbance in arteries. This situation is termed “atherosclerosis”, which results in a large number of diseases in the circulation system.
The occurrence of this condition is frequent in coronary arteries and leads to occlusion and stroke. Currently, stent placement and coronary artery bypass graft surgery are effective methods
for the treatment of atherosclerosis. Pressure-wire-based fractional flow reserve (FFR) is used to assess the severity of coronary stenosis and plan the revascularization procedure.
FFR is, therefore, a useful tool in angiography. The FFR method is considered as the gold standard to evaluate the significance of lesions with intermediate and borderline stenosis [ 1
]. The FFR-guided procedure can confer favorable clinical outcomes inasmuch as it can boost diagnostic accuracy, lessen the need for stenting, and reduce costs.
Nonetheless, FFR is measured in less than 10% of percutaneous coronary intervention (PCI) procedures because it needs pressure wires to measure the distal and proximal pressures
and adenosine to create hyperemic conditions. FFR measurement is, therefore, expensive and invasive. New research shows that the computational simulation of blood pressure and flow
based on computer equations can help diagnose and treat arterial occlusive disease [ 2
].A sudden reduction in the cross-section of an artery causes a pressure drop in the near stenosis region. According to the constraints on the determination of FFR,
the simulation of computational fluid dynamics (CFD) is currently considered as a method overcoming these problems as it can calculate FFR without the need for pressure wires and adenosine [ 3
].Tu et al. [ 4
] investigated pressure drop and velocity vectors in pre- and post-stenosis regions with the numerical simulation of the geometry of the diagonal artery and the left anterior
descending artery (LAD) derived from 2D X-ray angiography images based on the CFD method, assuming rigid arterial walls and steady-state blood flow.
They found that an increase in the degree of stenosis led into a reduction of flow and pressure and concluded that occlusion created an eddy in the flow pattern of blood.
Morris et al. [ 5
] evaluated hemodynamic parameters such as pressure and FFR in different degrees of stenosis on X-ray angiography and found a drop in pressure and FFR in the post-stenosis portion
of the right coronary artery in the hyperemic state. In the present study, blood was assumed to be non-Newtonian and steady-state flow and arterial walls were assumed to be rigid.
Young et al. [ 6
] conducted an angiography-derived numerical simulation of the blood flow in the LAD with the assumption that blood was a Newtonian fluid in arteries with rigid walls under a steady state.
They found a strong correlation between computationally simulated FFR and pressure-wire-based FFR in the hyperemic state.The aim of the current study was to present a new approach on the basis of 3D coronary angiography and the Thrombolysis in Myocardial Infarction (TIMI) frame count for
fast computation of FFR in patients with coronary artery disease. The accuracy of computationally simulated FFR was evaluated in patients with intermediate coronary stenosis
using pressure-wire-based FFR as the reference standard.
Material and Methods
Construction of Geometry
In this simulation study, two projections of patient-specific X-ray angiography images were obtained to construct computational geometry for the numerical simulation of the blood flow.
From each angiographic projection, a single end-diastolic frame was manually selected using Visionlite software. For the conversion of the pixel size to the millimeter,
a scaling factor was determined. The 3D centerline of the curvature of the coronary arteries was derived from the curve of the projection of the 2 views using Rhinoceros,
version 5.0. The lumen borders were manually detected in each angiographic projection, and the lumen centerline was calculated in each projection (Figure 1A).
Then, the 2D circular cross-section perpendicular to the centerline of the artery was extracted. The resulting 3D lumen volume generated meshes, which were thereafter
exported to the CFD solver (Figure 1B).
Figure 1
Coronary artery geometry from X-ray angiography images: (A) two projections (B) 3D model
Coronary artery geometry from X-ray angiography images: (A) two projections (B) 3D model
Governing Equations
In this study, numerical simulation was conducted under a steady condition. Arterial walls were defined as rigid and no-slip. Blood was assumed to be an incompressible, laminar,
and non-Newtonian fluid. The motion of the blood flow was assumed to be governed by continuity equation 1 and momentum equations 2 [ 7
].(1(2Where u, ρ, and τ are blood velocity, blood density and the stress tensor, which are defined by equation 3:(3Where μ and denote the viscosity of blood and the shear rate, respectively. In this work, the relation between μ and is described by equation 4:(4Where μ = 0.056 Pa.s, μ = 0.00354 Pa.s λ = 3.313 s, and n = 0.3568 and the shear rate is defined by equation 5:(5
Boundary Condition
The boundary condition of the inlet
The motive force of the blood flow is the pressure gradient in the aorta and the coronary artery. The outflow of the left ventricle is not always uniform because the aortic
valve creates flow disturbance. Although the exact effects of the aortic valve cannot be thoroughly simulated, the uniform inflow at the inlet of the coronary artery can be
ignored using pressure inlet boundary condition, which is similar to previous studies. Thus, the pressure inlet boundary condition in the present study is realistic [ 8
]. The mean arterial pressure (MAP) defined as the average pressure over the cardiac cycle is responsible for driving blood into the distal vessels and ultimately in the tissues [ 9
]. The MAP is estimated from equation 6:(6Where HR, SBP and DBP are the heart rate, the systolic blood pressure and the diastolic blood pressure, respectively. The contrast transport time in the reconstructed branch of the
coronary artery was calculated on rest projections using the TIMI frame count [ 10
]. The measured FFR values were considered blind. Figures 2 F1 to F9 show consecutive image frames in the resting state. The mean volumetric flow rate (VFR) in rest state was derived
from the lumen volume of the reconstructed coronary tree divided by the contrast transport time.
Figure 2
Boundary condition based on the Thrombolysis in Myocardial Infarction (TIMI) frame count of the angiographic images
Boundary condition based on the Thrombolysis in Myocardial Infarction (TIMI) frame count of the angiographic images
The boundary condition of the coronary outlet
Electrical circuit analogy was used to model the downstream arteries derived from the 3D model. This analogy created a relationship between pressure and the flow rate.
Lumped (0D) boundary conditions were specified at the outlet of each stenosis artery. The resting total coronary blood flow was calculated by the TIMI frame count of the X-ray angiography images [ 11
]. Hence, the branch resistance of each patient (R) was computed from the MAP and the mean flow (Q):(7In assigning boundary conditions, the final step was to simulate maximum hyperemia by modeling the effect of adenosine on reducing the peripheral resistance of the downstream
coronary arteries extracted from the X-ray angiography images. Wilson et al. [ 12
] showed that for arteries in which the resistance would be expected to be small both at rest and during hyperemia, total coronary resistance at maximum hyperemia fell to 0.21 of
the resting value with an intravenous administration of 140 mg/kg/min of adenosine. Hyperemic resistance is given by:(8Here, α is the under-relaxation factor, RHypermia, Old represents resistance in the last iteration, RHypermia, New represents this value in the next iteration and VFR stands for
the volumetric flow rate.The user-defined function was compiled to supply the resistance boundary conditions at the outlets. The downstream vasculature of the primary branches was coupled to the LAD model,
and the static pressure was solved iteratively at each outlet. Smooth convergence was ensured by attenuating the pressure gradient calculated at the outlet several times
to couple conditions of iterative under-relaxation-based resistance boundary with those outlets. In other words, an implicit algorithm was applied to the outlet with an under-relaxation factor given as:(9The numerical solution to equations 8 and 9 was carried out with an explicit Euler scheme. Subsequently, the equations were applied using FLUENT software in the form of user-defined function.
Computations
The numerical calculations were carried out using the finite volume method in ANSYS FLUENT software. Temporal and spatial discretization were performed with a second-order
backward Euler scheme and second-order central differencing, respectively. The pressure was solved through the pressure-velocity coupling method known as the “SIMPLE algorithm”.
The residual of the solution was kept at 0.00001, and the simulations were progressed under a steady-state condition. The computational mesh utilized in the primary simulations
consisted of nearly 300,000 triangular elements for diseased geometry. The triangular computational meshes were constructed in ANSYS ICEM CFD 16.0 (ANSYS Workbench).
The simulations were performed by a personal computer with a 2.5 GHz Core i5 Duo processor and 4 GB of RAM.
Results
Statistical analysis: correlation between NIFR with pressure-wire-based FFR
In the current study, FFR was calculated based on CFD derived from X-ray images in patients with intermediate stenosis in the LAD and the right coronary artery.
The statistical analyses were performed using SPSS (version 20.0.0). The Pearson correlation was applied to evaluate the correlation between NiFR and pressure-wire-based FFR.
There were several main findings. Figure 3A shows the correlation between NiFR and pressure-wire-based FFR. The NiFR (r = 0.738, P< 0.001)
exhibited a strong correlation with pressure-wire-based FFR. The result indicated that FFR was higher than 0.8 in the arteries with non-significant stenosis and
lower than 0.8 in the arteries with significant stenosis. The NiFR (mean difference = -0.00821, standard deviation = 0.0931) (Figure 3B) demonstrated a slight
difference but non-significant as compared with FFR in assessing the functional significance of stenosis on a per-vessel basis.
Figure 3
A) Correlation between pressure-wire-based fractional flow reserve (FFR) and Non-Invasive Flow Ratio (NiFR); B) Bland-Altman plot for the agreement of pressure-wire-based FFR and NiFR.
A) Correlation between pressure-wire-based fractional flow reserve (FFR) and Non-Invasive Flow Ratio (NiFR); B) Bland-Altman plot for the agreement of pressure-wire-based FFR and NiFR.
Discussion
Patients of coronary artery disease (CAD) may have one of the following on diagnostic coronary angiography: normal or mildly diseased coronary arteries (0% to 30% diameter stenosis),
stenosis of intermediate severity (30%-60%) and significant stenosis (60%-100%). The visual assessment based on the geometry of stenosis can be sufficient for diagnostic
significant and non-significant in the cases of normal and severe coronary, respectively. But, in many instances, visual and quantitative assessment alone may be insufficient
to establish stenosis with a moderate degree. Therefore, FFR should be measured to identify the hemodynamic parameters of lesions and the impact of stenosis on the parameters,
such as the impact of the lesion on the pressure and flow drop. We have developed a model that indicates the feasibility of using image base analysis and CFD techniques to
predict physiological state in coronary disease. In this study, pressure and flow can be calculated by a CFD solver, with generic boundary condition. There are several
advantages offered using physiological measures, which were derived from our CFD method. This method only requires coronary geometry. There is no need for the hyperemia flow,
additional procedure time and pressure wire. The current study has some limitations that the most important onesare relatively small population and retrospective design.
Another drawback is that only patients with lesions in the LAD were recruited. Therefore, more data are required to expand this application to other coronary vessels.
Moreover, our model was constructed without taking myocardial movement into account. Other studies have shown that myocardial motion exerts minor effects on the flow
distribution as compared with the effects of boundary conditions applied [ 13
]. Moreover, arterial walls were assumed to be rigid in our model. According to other studies, however, comparisons of the computational results between fluid-structure
interaction and rigid-wall models have shown that instantaneous (wall shear stress) distributions are affected by diameter variations in the arterial wall.
The effects of wall compliance on time-averaged wall shear stress (TAWSS) and the oscillatory shear index (OSI) are insignificant (4.5 and 2.7% difference in maximum TAWSS and OSI, respectively) [ 14
, 15
].
Conclusion
In the present study, FFR calculated based on CFD was utilized to assess the impact of stenosis on blood pressure and flow. Although regarded as the gold standard method,
FFR is used in less than 10% of PCI procedures because of its costs and invasive nature. According to CFD, we calculated NiFR in 85 patients. The results of the diagnostic
computational procedure demonstrated that FFR was higher than 0.8 for patients with a normal condition and lower than 0.75 for patients with significant stenosis.
This method was used to increase the utility of FFR assessment for patients with intermediate and borderline coronary stenosis. The computational simulation of FFR and
hemodynamic parameters such as pressure drop is a safe, efficient, and cost-effective method to evaluate the severity of coronary stenosis.
Acknowledgement
The authors sincerely thank the staff of the cardiac catheterization laboratory at Imam Khomeini Hospital, Tehran, Iran.
Authors’ Contribution
Mohamamd Sadeghian conceived the idea study concept, and supervised all the steps of the study. Vahid Mohammadi wrote the proposal, and collected the data collection.
Akbar Shafiee performed the data analysis, drafted the manuscript, and did the revisions. Hamidreza babakhani did the data coollection and image processing, and programmed the software.All the authors read and approved the initial and final draft of this manuscript.
Ethical Approval
The Ethics Committee of Tehran University of Medical Sciences approved the protocol of the study (IR.TUMS.IKHC.REC.1397.005).
Funding
This study was supported by Tehran University of Medical Sciences, Tehran, Iran (Grant for proposal No. 1160).
Authors: Nico H J Pijls; William F Fearon; Pim A L Tonino; Uwe Siebert; Fumiaki Ikeno; Bernhard Bornschein; Marcel van't Veer; Volker Klauss; Ganesh Manoharan; Thomas Engstrøm; Keith G Oldroyd; Peter N Ver Lee; Philip A MacCarthy; Bernard De Bruyne Journal: J Am Coll Cardiol Date: 2010-05-28 Impact factor: 24.094
Authors: Andy S C Yong; Austin C C Ng; David Brieger; Harry C Lowe; Martin K C Ng; Leonard Kritharides Journal: Eur Heart J Date: 2010-08-12 Impact factor: 29.983
Authors: Shengxian Tu; Stylianos A Pyxaras; Yingguang Li; Emanuele Barbato; Johan H C Reiber; William Wijns Journal: Circ Cardiovasc Interv Date: 2013-04 Impact factor: 6.546
Authors: C M Gibson; C P Cannon; W L Daley; J T Dodge; B Alexander; S J Marble; C H McCabe; L Raymond; T Fortin; W K Poole; E Braunwald Journal: Circulation Date: 1996-03-01 Impact factor: 29.690
Authors: A Theodorakakos; M Gavaises; A Andriotis; A Zifan; P Liatsis; I Pantos; E P Efstathopoulos; D Katritsis Journal: Phys Med Biol Date: 2008-08-18 Impact factor: 3.609
Authors: Gregory J Dehmer; Douglas Weaver; Matthew T Roe; Sarah Milford-Beland; Susan Fitzgerald; Anthony Hermann; John Messenger; Issam Moussa; Kirk Garratt; John Rumsfeld; Ralph G Brindis Journal: J Am Coll Cardiol Date: 2012-10-17 Impact factor: 24.094
Authors: Panagiotis K Siogkas; Michail I Papafaklis; Antonis I Sakellarios; Kostas A Stefanou; Christos V Bourantas; Lambros S Athanasiou; Themis P Exarchos; Katerina K Naka; Lampros K Michalis; Oberdan Parodi; Dimitrios I Fotiadis Journal: Biomed Res Int Date: 2015-03-01 Impact factor: 3.411
Authors: Paul D Morris; Desmond Ryan; Allison C Morton; Richard Lycett; Patricia V Lawford; D Rodney Hose; Julian P Gunn Journal: JACC Cardiovasc Interv Date: 2013-02 Impact factor: 11.195