Assessing the robustness of artificial intelligence powered planning tools in radiotherapy clinical settings-a phantom simulation approach.

Martin Hito1, Wentao Wang2, Hunter Stephens2, Yibo Xie2, Ruilin Li2, Fang-Fang Yin2, Yaorong Ge3, Q Jackie Wu2, Qiuwen Wu2, Yang Sheng2.   

Abstract

BACKGROUND: Artificial intelligence (AI) based radiotherapy treatment planning tools have gained interest in automating the treatment planning process. It is essential to understand their overall robustness in various clinical scenarios. This is an existing gap between many AI based tools and their actual clinical deployment. This study works to fill the gap for AI based treatment planning by investigating a clinical robustness assessment (CRA) tool for the AI based planning methods using a phantom simulation approach.
METHODS: A cylindrical phantom was created in the treatment planning system (TPS) with the axial dimension of 30 cm by 18 cm. Key structures involved in pancreas stereotactic body radiation therapy (SBRT) including PTV25, PTV33, C-Loop, stomach, bowel and liver were created within the phantom. Several simulation scenarios were created to mimic multiple scenarios of anatomical changes, including displacement, expansion, rotation and combination of three. The goal of treatment planning was to deliver 25 Gy to PTV25 and 33 Gy to PTV33 in 5 fractions in simultaneous integral boost (SIB) manner while limiting luminal organ-at-risk (OAR) max dose to be under 29 Gy. A previously developed deep learning based AI treatment planning tool for pancreas SBRT was identified as the validation object. For each scenario, the anatomy information was fed into the AI tool and the final fluence map associated to the plan was generated, which was subsequently sent to TPS for leaf sequencing and dose calculation. The final auto plan's quality was analyzed against the treatment planning constraint. The final plans' quality was further analyzed to evaluate potential correlation with anatomical changes using the Manhattan plot.
RESULTS: A total of 32 scenarios were simulated in this study. For all scenarios, the mean PTV25 V25Gy of the AI based auto plans was 96.7% while mean PTV33 V33Gy was 82.2%. Large variation (16.3%) in PTV33 V33Gy was observed due to anatomical variations, a.k.a. proximity of luminal structure to PTV33. Mean max dose was 28.55, 27.68 and 24.63 Gy for C-Loop, bowel and stomach, respectively. Using D0.03cc as max dose surrogate, the value was 28.03, 27.12 and 23.84 Gy for C-Loop, bowel and stomach, respectively. Max dose constraint of 29 Gy was achieved for 81.3% cases for C-Loop and stomach, and 78.1% for bowel. Using D0.03cc as max dose surrogate, the passing rate was 90.6% for C-Loop, and 81.3% for bowel and stomach. Manhattan plot revealed high correlation between the OAR over dose and the minimal distance between the PTV33 and OAR.
CONCLUSIONS: The results showed promising robustness of the pancreas SBRT AI tool, providing important evidence of its readiness for clinical implementation. The established workflow could guide the process of assuring clinical readiness of future AI based treatment planning tools. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Radiation therapy; artificial intelligence (AI); knowledge-based planning; machine learning; treatment planning

Year:  2021        PMID: 34888193      PMCID: PMC8611457          DOI: 10.21037/qims-21-51

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  34 in total

1.  Task Group 142 report: quality assurance of medical accelerators.

Authors:  Eric E Klein; Joseph Hanley; John Bayouth; Fang-Fang Yin; William Simon; Sean Dresser; Christopher Serago; Francisco Aguirre; Lijun Ma; Bijan Arjomandy; Chihray Liu; Carlos Sandin; Todd Holmes
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

Review 2.  Overview of artificial intelligence-based applications in radiotherapy: Recommendations for implementation and quality assurance.

Authors:  Liesbeth Vandewinckele; Michaël Claessens; Anna Dinkla; Charlotte Brouwer; Wouter Crijns; Dirk Verellen; Wouter van Elmpt
Journal:  Radiother Oncol       Date:  2020-09-10       Impact factor: 6.280

3.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40.

Authors:  G J Kutcher; L Coia; M Gillin; W F Hanson; S Leibel; R J Morton; J R Palta; J A Purdy; L E Reinstein; G K Svensson
Journal:  Med Phys       Date:  1994-04       Impact factor: 4.071

4.  Machine Learning for Patient-Specific Quality Assurance of VMAT: Prediction and Classification Accuracy.

Authors:  Jiaqi Li; Le Wang; Xile Zhang; Lu Liu; Jun Li; Maria F Chan; Jing Sui; Ruijie Yang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2019-08-01       Impact factor: 7.038

5.  Atlas-guided prostate intensity modulated radiation therapy (IMRT) planning.

Authors:  Yang Sheng; Taoran Li; You Zhang; W Robert Lee; Fang-Fang Yin; Yaorong Ge; Q Jackie Wu
Journal:  Phys Med Biol       Date:  2015-09-08       Impact factor: 3.609

6.  Automating quality assurance of digital linear accelerators using a radioluminescent phosphor coated phantom and optical imaging.

Authors:  Cesare H Jenkins; Dominik J Naczynski; Shu-Jung S Yu; Yong Yang; Lei Xing
Journal:  Phys Med Biol       Date:  2016-08-12       Impact factor: 3.609

7.  Goal-Driven Beam Setting Optimization for Whole-Breast Radiation Therapy.

Authors:  Wentao Wang; Yang Sheng; Sua Yoo; Rachel C Blitzblau; Fang-Fang Yin; Q Jackie Wu
Journal:  Technol Cancer Res Treat       Date:  2019-01-01

8.  Automatic Planning of Whole Breast Radiation Therapy Using Machine Learning Models.

Authors:  Yang Sheng; Taoran Li; Sua Yoo; Fang-Fang Yin; Rachel Blitzblau; Janet K Horton; Yaorong Ge; Q Jackie Wu
Journal:  Front Oncol       Date:  2019-08-07       Impact factor: 6.244

Review 9.  A Review on Application of Deep Learning Algorithms in External Beam Radiotherapy Automated Treatment Planning.

Authors:  Mingqing Wang; Qilin Zhang; Saikit Lam; Jing Cai; Ruijie Yang
Journal:  Front Oncol       Date:  2020-10-23       Impact factor: 6.244

View more