Literature DB >> 34882725

Study on the effect of front retaining walls on the thermal structure and outflow temperature of reservoirs.

Xiaoqian Yang1, Youcai Tuo1, Yanjing Yang1, Xin Wang2, Yun Deng1, Haoyu Wang1.   

Abstract

The front retaining wall (FRW) is an effective facility of selective withdrawal. Previous research has not estimated the effect of FRWs on the thermal regimes of reservoirs and outflow temperature, which are crucial to reservoir ecology. For this purpose, taking the Dongqing Reservoir as a case study, a two-dimensional hydrodynamic CE-QUAL-W2 model was configured for the typical channel-type reservoir in the southwestern Guizhou Province, to better understand the influence of FRWs on the thermal structure and outflow temperature. The simulated data from January to September 2017 showed that FRWs can change the vertical temperature distribution during the stratification period, accelerate the upper warmer water release and thus decrease the strength of thermal stratification. The stratification structure changed from a single thermocline to double thermoclines in August. An FRW resulted in an average 11.8 m increase in the thickness of the hypolimnion and a 1.2°C decrease in the thickness of the thermocline layer. An FRW increased the outflow temperature by 0.4°C and raised the withdrawal elevation by 16 m on average. The longitudinal velocity increased compared with the non-FRW condition, while the maximum velocity position moved up. In addition, FRWs can continuously obtain surface warmer water without manual operation and have low investment and good construction conditions. This study can provide an available selective withdrawal idea for reservoirs with similar hydraulic conditions.

Entities:  

Mesh:

Year:  2021        PMID: 34882725      PMCID: PMC8659636          DOI: 10.1371/journal.pone.0260779

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


1. Introduction

When a dam impoundment meets a variety of water supply needs, it is bound to have an impact on the spatiotemporal variation in the water temperature in the reservoir and downstream sections [1]. Water Temperature is an essential environmental factor of reservoirs that can affect water quality, nutrient distribution and even ecosystems [2,3]. Due to the increase in water depth, slow flow rate and longer time for surface water to receive solar radiation in reservoirs, vertical temperature stratification usually occurs in deep reservoirs [4], which has different impacts on the thermal state of the reservoir area and the structure and function of the ecosystem [5,6]. In practice, stratification in reservoirs is affected by natural processes (such as meteorological conditions) [7] and reservoir operation schemes. Moreover, stratification will also lead to the phenomenon of discharged low water temperature in summer [8], significantly changing the characteristics of water temperature in downstream rivers and harming the water quality, metabolism and reproduction of aquatic organisms and agricultural irrigation [9,10]. Thus, research on the evolution law of the stratified thermal state and discharged water temperature is the basis for optimizing the allocation of reservoir water [11]. Reservoirs with a single outlet might release water that is too warm or too cold for downstream ecosystems, depending on reservoir temperature at the intake [3]. Currently, considering the severe effect of bottom-intake for withdrawal on ecology [12,13], which was commonly employed in some north temperate countries in the 1960s, selective withdrawal systems have been widely used to meet downstream temperature and other water quality objectives [14,15], such as stoplog gates [16] and temperature-control curtains (TCCs) [17]. With the objective of water quality changing, applying a selective withdrawal facility to a certain reservoir involves many factors such as the improvement effect of outflow temperature, reservoir operation and management mode, economic investment, safety performance and so on [18]. Focusing on a reservoir that has impounded water, in regard to a deep run-off reservoir, which can redistribute the natural inflow of reservoirs in a day according to the daily load change process, the water level changes less and a facility with variable withdrawal elevation like a stoplog gate or temperature-control curtain is not necessary [19,20]. A front retaining wall (FRW) may be a more suitable choice which can meet the needs of the easy operation and low cost. The front retaining wall (FRW) is an available fixed-elevation selective withdrawal facility composed of reinforced concrete. In terms of the flow region, a wall can be set before the water intake and supported by the arms to block bottom water from entering the water intake. Usually, the top elevation of an FRW is greater than the elevation of the water intake. In summary, the FRW is a new selective facility that has been successfully used in the Dongqing Reservoir to reduce summer outflow temperature in the high-temperature period. There have been many studies on the selective withdrawal systems and facilities [21,22]. However, little attention has been specially given to the FRW, which is proven to have an impact on the ecology downstream. Many scholars have drawn a conclusion that selective withdrawal is the most effective means of controlling the quality of water released downstream [23]. Deeper withdrawals also facilitate heat transfer in the water column, increase the thickness of the metalimnion and weaken the stratification stability [20,24]. Through experimental study and numerical simulation, TCCs with different water-retaining proportions have been found to affect the flow field and thermal characteristic in reservoirs [25]. A top-TCC is recommended for a smaller thermal stability or a cool outflow in the summer [26]. Stop-log gates can mitigate the cold temperature effect in spring and summer [27]. Moreover, stoplog gates can influence the flow patterns including the flow regime and velocity distribution at the intake and the flow velocity at the trash rack section varies vertically in a great manner [16]. Thus, for distinct water management requirements, both relevant selective withdrawal systems and corresponding thermal properties may have a certain gap. As a new engineering measure, an FRW is mainly designed for the controlling of water released downstream. Tuo et al. illustrated the remained old dam dismantled above 240.2 m asl, standing before the new dam and acting as an FRW in Fengman Reservoir (in northeast China), can strengthen the flow motion in the surface layer and lower the outflow temperature in winter [28]. However, no studies have quantified the influence of FRWs on the thermal characteristics in reservoirs, outflow laws and hydraulic characteristics, which are crucial to the reservoir water environment. Dongqing Reservoir is a deep and impounded reservoir in China. An FRW was initially recommended to regulate the outflow temperature, and its effect on the thermal structure is unknown. Taking Dongqing Reservoir as a case study, this paper aims to analyze the flow and temperature field of the reservoir under FRW scenarios and to obtain their potential effects on the thermal structure and outflow properties. In this study, field observations were carried out in the Dongqing Reservoir from January to September 2017, and a two-dimensional hydrodynamic CE-QUAL-W2 model was established to simulate the vertical water temperature in front of the dam and discharged water temperature with and without an FRW. The stratification characteristics, thermal stability and hydrodynamic characteristics of the water temperature were compared and analyzed. This study can provide a new idea and strategy for the management of selective withdrawal in deep reservoirs.

2. Materials and methods

2.1 Study site and data acquisition

Dongqing Reservoir (25° 31’N, 105° 46’E) is a narrow, long and deep reservoir located in southwestern Guizhou Province, China, with a surface area of 13,500 km2, a maximum dam height of 149.5 m, a maximum water depth of 120 m, an average annual runoff of approximately 12.56×109 m3 and a storage capacity of 9.55×108 m3 under 490 m asl. The reservoir is a typical subtropical reservoir with an average air temperature of 16.6°C/yr. The average yearly flow in the reservoir is 398 m3/s. The main reservoir is located on the Beipan River with a backwater length of 41 km, while the tributary is the Dabang River with a backwater length of approximately 26 km. A tower inlet is adopted by the power station with a floor elevation of 455 m asl. A cantilever-type reinforced concrete retaining wall is set at 13.5 m in front of the inlet, and both sides of the retaining wall are connected to the inlet side pier. The top elevation of the wall is 470 m asl with height of 15 m and thickness of 2 m (Fig 1).
Fig 1

Map of study locations and the structure of the water intake of Dongqing Hydropower station.

(a) Map of study locations. (b) FRW and the structure of the water intake.

Map of study locations and the structure of the water intake of Dongqing Hydropower station.

(a) Map of study locations. (b) FRW and the structure of the water intake. To understand the thermal characteristics of this reservoir, we monitored the water temperature from January to September 2017, including vertical profile measurements (Fig 1B1 at predams), inflow water temperature (Fig 1A1 and 1A2), and outflow water temperature (Fig 1A3). A vertical thermal chain was set at section B1 (900 m upstream in front of the dam) for long-term high-frequency monitoring using a TIDBIT V2 (UTBI-001) temperature recorder (Onset, USA) at a measuring interval of 1 h. The vertical intervals of 43 water temperature sensors for the chain were 1 m (0–10 m depth), 2 m (10–50 m depth), and 4 m (50–100 m depth). The water temperatures of inflow and outflow were measured by a ZDR self-recording thermometer. The inflow observation section was settled at the end of the mainstream backwater (A1) and tributary backwater (A2), and the outflow monitoring section was in the release water of Dongqing Power Station (A3) at a measuring interval of 1 h.

2.2 Numerical methods and simulations

In this paper, an unsteady two-dimensional model (along the longitudinal and vertical directions) is the minimum requirement to study spatial-temporal thermal regime variations in the Dongqing Reservoir (Fig 1), which is a long-but-narrow reservoir with a longitudinal gradient in temperature that is not small enough to be neglected. Consequently, we conducted the present study by using CE-QUAL-W2, a two-dimensional laterally averaged hydrodynamic and water quality model [29]. This model is mainly applied to water bodies with longitudinal and vertical temperature gradients. It provides accurate simulations of stratification and density currents and has been widely used to study various reservoirs and river impoundments worldwide [30,31]. We use this model to quantify thermal stratification and hydrodynamics in the Dongqing Reservoir. This model is a water quality and hydrodynamic model developed by the U.S. Army Corps of Engineers and Portland State University [29], mainly for rivers, estuaries, lakes and reservoirs in the longitudinal or vertical direction. We constructed a longitudinal and vertical two-dimensional water temperature model for the whole reservoir area, and it ignored the variation in various variables along the width. The Dongqing Reservoir was divided into 198 × 86 (longitudinal × vertical) rectangular cells, with 124 cells for the main reservoir and 74 cells for the branch reservoir. The longitudinal size of the cell grid was 10–500 m, and the vertical size was 1–2 m. The input boundary (S1 Fig) included relative operation data (inflow, outflow, inflow water temperature and water level) and meteorological data (including air temperature, solar radiation, humidity, wind speed, cloud and wind direction). The temperature field at the initial moment was obtained after interpolation based on the vertical water temperature measured in the reservoir area on January 1, 2017. To explore the effect of the retaining wall on the thermal state of the reservoir area and the improvement in the low discharged water temperature, we use a numerical model to simulate the water temperature and hydrodynamics under two conditions with and without a retaining wall. The condition with the retaining wall is defined as Case 1, while the condition without the retaining wall is defined as Case 2.

2.3 Index of thermal stratification and statistics analysis

We selected indicators to quantify the thermal stratification of water bodies and evaluate the characteristics of thermal structure of stratification. The vertical water temperature gradient (VTG, °C/m; 0.12°C/m was defined as the threshold of strong stratification here (Fig 2) [32] and the buoyancy frequency (N, 1/s) [33] was calculated based on the water temperature profiles of the vertical section in front of the dam. where T(z) is the water temperature at depth z, °C; ρ(z) is the density at depth z, kg/m3; ρ0 is the average density of the whole water column, kg/m3; g is the acceleration of gravity, m/s2; and N is an important indicator used in limnology, oceanography and human-made reservoirs. The change trend of N can be used to evaluate the stratified stability of water columns. N indicates that in a stable temperature-stratified structure, the fluid particles move in the vertical direction after being disturbed. The combined effect of gravity and buoyancy always returns these factors to an equilibrium position, which oscillates due to inertia. The oscillation frequency can be understood as the exchange rate of water.
Fig 2

Comparison of simulated and observed values of vertical temperature distribution.

The line represents the calculated values, while the dots represent the measured values.

Comparison of simulated and observed values of vertical temperature distribution.

The line represents the calculated values, while the dots represent the measured values. To better evaluate the changes in the stratification stability of the water column, the SI index, which reflects the stability of the deep water body, was used to evaluate the strength of the stratification stability of the reservoir [34]. where Z is the depth of the water column from the surface; Z0, Zl and are the depths of the surface water, the lower end of the water column, and the centroid of the water column, respectively; and ρz is the water density at depth Z. SI can be converted into energy by multiplying by the acceleration of gravity and the volume of each layer, and SI represents the ideal energy estimate of the entire water column to achieve mixing in the depth range without an increase or decrease in heat. We used the root mean square error (RMSE) and mean absolute error (MAE) to evaluate the goodness of the fitted temperature curve, as well as the differences between the observed and simulated temperatures. A paired T-test was conducted to determine the significance levels of the differences in the (a) water temperature structure and (b) stratification stability index between two different withdrawal conditions. A value of P<0.01 was defined as significant. Moreover, the correlation coefficient R2 was employed to assess the goodness of fit between the measured and simulated values of discharge water temperature with the retaining wall. The closer R2 is to 1, the stronger the data correlation and the higher the simulation accuracy is.

3. Results and discussion

3.1 Model calibration and validation

The calibration of Dongqing Reservoir’s CE-QUAL-W2 model focused on several critical coefficients that had the greatest influence on the simulated temperature profiles upstream of the dam. The critical model parameters are the longitudinal eddy viscosity coefficient, longitudinal eddy diffusion coefficient, wind shielding coefficient, extinction for pure water, solar radiation absorbed in the surface layer and dynamic shading coefficient (Table 1). The calibration and value of these parameters referred to previous research [32,35,36].
Table 1

Calibrated parameters in the CE-QUAL-W2 model of the Dongqing reservoir.

ParameterUnitValue
Longitudinal eddy viscositym2/s1
Longitudinal eddy diffusivitym2/s1
Wind sheltering coefficient-1
Extinction for pure waterm-10.5
Solar radiation absorbed in the surface layer-0.65
Dynamic shading coefficient-1
We compared the calculated results and measured data for upstream of the dam (Fig 2) and outflow temperature (Fig 3) based on hydrological and meteorological data from January to September 15, 2017, which were obtained from the monitoring of the upstream and downstream power station of the Dongqing Reservoir and the meteorological website (http://www.cma.gov.cn/2011qxfw/2011qsjgx/), respectively. The temperature variation trends of the epilimnion and metalimnion were consistent, and the temperature of the hypolimnion was generally well matched. The average MAE and RMSE of the vertical water temperature in front of the dam from January to September were 0.46°C and 0.62°C, respectively. This was mainly because the meteorological data originated from the Zhenfeng Meteorological Station. The station was approximately 40 km away from the dam site whose wind speed and direction deviated from the wind conditions in the open area of the reservoir area. Although we calibrated the wind shielding coefficient to be 1.0, there may still be a certain deviation in wind direction and speed. However, these errors are within a reasonable range, with relative errors of 4.4% and 3.5% in July and August, respectively.
Fig 3

Comparison of simulated and observed values of outflow temperature.

The line represents the calculated values, while the dots represent the measured values.

Comparison of simulated and observed values of outflow temperature.

The line represents the calculated values, while the dots represent the measured values. The scatter plot of the measured and calculated outflow temperatures (Fig 3) showed that the degree of dispersion of the error was small with an MAE of 0.23°C and RMSE of 0.3°C. The determination coefficient between the measured value and calculated value was 0.9917. The results showed that the model can accurately simulate the effects of buoyancy flow and atmospheric heat exchange on the thermal structure of water temperature.

3.2 Effect of a retaining wall on thermal stratification

3.2.1 Temperature profiles in different cases

Fig 4 compares the vertical water temperature distribution in front of the dam with or without an FRW from January to September 2017. The results showed consistent seasonal variation characteristics under both conditions. Stratification began during the warming period (April). Until the high-temperature period (August), the maximum temperature difference between the surface layer (epilimnion) and bottom layer (hypolimnion) increased to 11°C. A double thermocline structure existed simultaneously because of a larger inflow discharge, whose temperature was lower than that of the epilimnion and dived along the reservoir into the layer with the same density, forming a horizontal intrusion flow. The initial momentum of inflow during the submersion process was large, leading to severe turbulent diffusion and a strong mixing effect, thus forming an isothermal layer with a certain thickness and the middle thermocline.
Fig 4

Temperature profiles at 1–2 m intervals simulated based on different cases and the corresponding buoyancy frequency (N) for the entire water column during 2017.

ΣN indicates the total stratification intensity.

Temperature profiles at 1–2 m intervals simulated based on different cases and the corresponding buoyancy frequency (N) for the entire water column during 2017.

ΣN indicates the total stratification intensity. The stratification structure under the two cases differed greatly for different withdrawal modes, mainly in the stratification period (Fig 4, paired T-test: P < 0.01, April to September). With the development of stratification, the water temperature isoline gradually extended to the bottom owing to the increasing air temperature and heat storage (Fig 6A and 6D), and in case 2, it extended much earlier to the bottom. The average vertical temperature of the whole profile varied from 16.1°C to 28.3°C in case 1, while that of case 2 ranged from 16.2°C to 34°C. This is because deeper low-temperature water was discharged leading to more heat storage capacity when there was no FRW. The thickness of the thermocline in case 1 was 8 m-16 m smaller than that in case 2, and the thickness of the hypolimnion exhibited the opposite trend (8 m-14.5 m). For example, during the double thermocline period in August, the depth of the middle isothermal layer in case 1 was 12 m higher than that in case 2 owing to the lower water temperature in the epilimnion and thermocline resulting in a smaller diving depth of the inflow. The thickness of the hypolimnion was 58 m in case 1 and 50 m in case 2.
Fig 6

Variation in reservoir SI from January to September 2017 in different cases.

3.2.2 Thermal stratification strength characteristics

Selective withdrawal can change the thermal stratification intensity of reservoirs [37]. We can see from Fig 4 that the variation rule in N was consistent with the VTG, and the peak value of N is the location of the thermocline (Fig 4). ΣN represents the overall buoyant flow strength of the water column. The larger ΣN was, the greater the density stratification strength. Thus, the density stratification in case 2 was more intense than that in case 1. In August, ΣN was 0.724 and 0.921 in case 1 and 2, respectively. Fig 5 present the temperature contour, VTG and N variations upstream of Dongqing Dam for the two cases over time. In April, the stratified flow developed initially with changes in meteorological conditions and inflow conditions. From May to June, stratification strengthened. The water temperature at a depth of 10 m increased rapidly, and the density decreased. Influenced by the buoyancy jacking effect, N varied from 0.02 s-1 to 0.08 s-1. From July to August, the inflow of the reservoir increased (798 m3/s), and the solar radiation increased (186 W/m2 on average per month). In case 1, the main flow layer was located near 470 m, and N increased from 0.02 s-1 to 0.067 s-1. The inflow mixed quickly within a range of 455 m to 465.5 m, forming an isothermal layer. Moreover, the epilimnion appeared with an N of 0.028 s-1. The temperature of the hypolimnion remained stable and was no longer affected by the turbulence caused by the FRW. The water column presented a density stratified flow state between layers. Comparatively, in case 2, the mean plug flow was located near 458 m with N of 0.02 s-1. The depth of the middle thermocline decreased significantly, and the surface water was supported by buoyancy, while the hypolimnion was compressed to below 420 m asl.
Fig 5

From January 1 to September 15, 2017, the contour profile of the cross section (B1) 0.9 km upstream of Dongqing Dam for two conditions (a-c for case 1 and d-f for case 2) and (a, d) water temperature contour, (b, e) vertical temperature gradient and (c, f) buoyancy frequency.

From January 1 to September 15, 2017, the contour profile of the cross section (B1) 0.9 km upstream of Dongqing Dam for two conditions (a-c for case 1 and d-f for case 2) and (a, d) water temperature contour, (b, e) vertical temperature gradient and (c, f) buoyancy frequency. Fig 6 compares the daily variation in SI in two cases (kg/m2). Their annual variation trends of reservoir SI were similar, with averages of 402 kg/m2 (case 1) and 516 kg/m2 (case 2). As the temperature rose, the stratification intensity continued to increase. Stratification of the water column gradually strengthened from weak stratification to stable stratification. The SI value was significantly distinct in the two cases (p<0.01). In case 1, the temperature of the epilimnion was lower and the maximum temperature difference between the epilimnion and hypolimnion decreased. The ability to resist heat convection, surface wind stress and density convection caused by low-temperature inflow was relatively weaker, so the water column stability was weaker. With the arrival of high temperatures in the flood season, the replacement of water bodies was accelerated, while stratification was not weakened. The SI difference between the two cases reached a maximum in July, with an average difference of 522 kg/m2. This was because of the sudden increase in flow in July and the weaker stratification stability in case 1, resulting in more intense mixing than in case 2.

3.3 Influence of the retaining wall on outflow temperature

3.3.1 Variations in outflow temperature

In subtropical reservoirs in China, many warm-water fish (such as four major Chinese carps) are quite sensitive to outflow temperature in summer and autumn [38], and the discharged low-temperature water affects the spawning, reproduction and migration of fish. The discharged water temperature is related to the vertical temperature distribution of predams, the flow velocity near the water intake, and the flow [39]. A comparison of discharge water temperature under different working conditions is shown in Fig 7. The FRW has an obvious influence on the outflow temperature (p<0.01). Compared with the natural water temperature of the dam site, the discharge water temperature was lower in the two cases from March to September, while the degree of low-temperature water was weakened in case 1. Due to the effect of the FRW, the discharged water temperature from March to June increased by 0.1°C~1.0°C. The maximum difference appeared in May (1°C). Due to the effect of meteorological conditions, the water temperature near the top elevation of the FRW (470 m asl) increased rapidly while the mixing caused by thermal convection did not move down to the vicinity of 455 m asl. The difference in water temperature near these two elevations reached the largest value. August was the double thermocline period, and the middle isothermal layer where the interlayer flow was located was near 455 m asl. There was no significant temperature difference between the middle isothermal layer in case 2 and the upper thermocline in case 1, so the outflow low-temperature water only improved by 0.3°C. In general, the FRW mitigated the influence of low-temperature water in spring and summer at Dongqing Hydropower Station.
Fig 7

Released water temperatures in different cases.

3.3.2 Flow velocity distribution

The flow velocity distribution is an essential indicator of the hydrodynamic characteristics, and it is usually characterized by the maximum flow velocity and its position. In this paper, to examine the velocity distribution to analyze the withdrawal properties, we selected April in the heating period, July in the high-temperature period and September in the cooling period to explore the flow velocity changes in different periods caused by the FRW (Fig 8).
Fig 8

Elevations of the withdrawal layer in different months and different working conditions and the local flow field distribution in front of the dam in April, July and September: a, c and e show the flow field with the retaining walls, and b, d and f show the flow field without retaining walls.

Elevations of the withdrawal layer in different months and different working conditions and the local flow field distribution in front of the dam in April, July and September: a, c and e show the flow field with the retaining walls, and b, d and f show the flow field without retaining walls. In Fig 8A~8F, the results showed that the FRW raised the withdrawal elevation by 16m on average. The withdrawal elevation ranged from 472.5 m to 479 m asl with the FRW and ranged from 455~462 m asl with no-FRW. The FRW hindered access to water bodies below 470 m asl, allowing water bodies above 470 m asl to flow into the water intake. In case 2, the water flowed smoothly into the water intake while the flow pattern near the top of the FRW was more complex in case 1. The position of the water withdrawal layer was elevated to a warmer layer with a higher temperature, leading to more warm water release and more heat loss, which further changed the vertical water temperature structure in front of the dam (Fig 5) and lowered the upper water temperature. For example, in July, when the flow reached its peak and the increasing amplitude of the withdrawal elevation was at the minimum (14.5 m), the water temperature of the 477 m withdrawal layer in case 1 was 21.1°C, which was lower (1.3°C) than that in case 2. Therefore, the discharge water temperature only increased by 0.1°C. The layer with the maximum flow rate is recognized as the mean plug layer. In case 2, the quantity of water taken from the upper and lower layers of the mean plug layer was relatively even while the opposite was observed in case 1. In case 1, more water was taken from the upper layer, and the mean plug layer was compressed, which increased the maximum velocity. For example, in April, the center elevation of the mean plug layer with an FRW was 15 m higher than that without an FRW. The maximum velocities in case 1 and case 2 were 0.063 m/s and 0.055 m/s, and the thicknesses of the mean plug layer were 30 m and 35 m, respectively; in July, the flow reached the maximum, the velocities also increased to 0.146 m/s and 0.101 m/s, and the thicknesses of the withdrawal layer were 33 m and 39.5 m for cases 1 and 2, respectively. The release of warm water from the upper layer intensified as the flow rate increased.

3.3.3 Equivalent withdrawal elevation

The discharged water temperature is closely related to the vertical water temperature profile in front of the dam and the water withdrawal elevation [40,41]. Generally, when the stratification in front of the dam is obvious and the elevation of water intake is high, the discharged water temperature is high. To more intuitively express and analyze the position difference in the withdrawal layer, the equivalent withdrawal elevation is defined in this study as the elevation of the withdrawal layer corresponding to the same water temperature in front of the dam. The results show that the corresponding distributions of the water temperature and temperature gradient at equivalent elevations in the two cases are shown in Fig 9. From the distribution of the equivalent elevation, we can see the location of the withdrawal layer. The red line in the figure is the top elevation of the retaining wall while the blue spots represent the equivalent elevation points.
Fig 9

Position of the equivalent elevation point in the water level-water temperature and water level-temperature gradient distribution diagram.

a and b are the water temperature and VTG distribution diagram with a retaining wall, respectively, while c and d are the water temperature and VTG distribution diagram without a retaining wall, respectively. The red dotted line represents the position of the top elevation of the retaining wall, and the blue scattered points represent the equivalent elevation point.

Position of the equivalent elevation point in the water level-water temperature and water level-temperature gradient distribution diagram.

a and b are the water temperature and VTG distribution diagram with a retaining wall, respectively, while c and d are the water temperature and VTG distribution diagram without a retaining wall, respectively. The red dotted line represents the position of the top elevation of the retaining wall, and the blue scattered points represent the equivalent elevation point. When there is an FRW, the withdrawal layer is above the retaining wall (near 470 m), while the withdrawal layer is below the intake (near 455 m) without an FRW. In July, since the inflow and outflow were large, the turbulence near the intake was intense, and the position of the withdrawal layer increased accordingly. In the two cases, the equivalent elevation points were all located at the bottom of the thermocline because the density gradient of the layer adjacent to the thermocline boundary was larger and the buoyancy effect was stronger than that of other layers (Fig 9C and 9D). The vertical mixing caused by density convection and turbulent diffusion was suppressed, and the downward transfer of surface energy was hindered at the boundary of the thermocline. The discharged water temperature was closely related to the water withdrawal elevation, so it was an effective means to improve the outflow temperature by first increasing the water withdrawal elevation. Second, the mixing of the upper warm water layer is strengthened to reduce the temperature difference in the thermocline layer, thus weakening the inhibitory effect of buoyancy.

3.4 Engineering applications and prospects for this study

As a new type of selective withdrawal facility, what makes front retaining walls mainly differ from other selective withdrawal facilities is that the fixing the FRW elevation makes it unnecessary for additional manual operation [42], which can provide a new idea for the adaptive water temperature management of run-off reservoirs with a relatively low amplitude. Generally, the water level of reservoirs with different operations varies greatly. The stoplog gate and temperature-control curtain can be lifted or lowered to adjust the water temperature with the water level changing [35,43-45]. However, the water level in run-off reservoirs varies less. No frequent manual operation is required to obtain the same outflow temperature. Therefore, the FRW is more suitable for this kind of reservoir. Second, this study shows that the improvement effect of the outflow temperature with the FRW is good. For example, the water level of the Dongqing reservoir ranges from 484m to 490m. The lowest elevation of the mean plug flow is 472.5 m (June, Fig 8) near the upper thermocline, causing that the upper high-temperature water body can be continuously obtained. The maximum improvement of discharged water temperature can reach 1°C, which has a good improvement effect in engineering management. From the aspect of engineering, FRWs are achieved with a small investment and have simple operation conditions and good construction conditions, which can provide a reference for the selection of stratified water intake measures. At present, when various selective withdrawal facilities are applied, such as stoplog gates and temperature-control curtains, it is necessary to initially determine the period for discharged low-temperature water initially. The withdrawal elevation determines the elevation conversion of the water intake. As the water level is below the submerged depth of the water intake, the intake is switched from high to low, which usually results in a sudden decrease in the outflow temperature [46]. The water temperature after lowering is lower than that without selective withdrawal facilities. Such a low temperature often causes much more severe impacts on downstream ecosystems and agricultural irrigation. Due to the fixed elevation of the front retaining wall, we can continuously obtain upper layer warm water, which will not result in sudden low-temperature water. The front retaining wall is set at a certain distance in front of the dam, so compared with the fixed intake, the head loss is relatively small, and the influence on power generation efficiency is small.

4. Conclusions

FRWs are a new and effective method to regulate the outflow temperature. To strengthen research on FRWs, this paper numerically investigated the effect of FRWs on the thermal structure in the deep Dongqing Reservoir and evaluated the potential function of FRWs in water environment management. The conclusions are described as follows: The retaining wall significantly changed the water temperature distribution structure and reduced the thermal stability strength of the reservoir during stratification. The retaining wall increased the thickness of the thermocline layer to further restrain the downward transfer of heat. Simultaneously, the water temperature and the thickness of the upper warmer water layer were reduced. The stratification strength of the thermocline layer also decreased. ΣN was less than that without retaining walls, and SI was also relatively lower with a maximum difference of 522 kg/m2 (July). The retaining wall can increase the discharge water temperature during stratification by 0.4°C on average and reaching the maximum (1°C) in May. Specifically, in the period of the double thermocline (July and August), the discharge temperature only increased by 0.2°C on average. The location of the mean plug layer ranged from 472.5 m to 479 m asl with the FRW and ranged from 455 m~462 m asl with no FRW. The equivalent withdrawal elevation points were distributed at the bottom of the thermocline. If the discharged water temperature rises, the water intake elevation can be lifted to reduce the temperature difference in the thermocline and weaken the inhibiting effect of buoyancy. Retaining walls are more suitable for stratified deep run-off reservoirs with stable water levels without frequent manual operation. The upper warmer water can be continuously obtained, and the outflow water temperature will not suddenly decrease, resulting in more severe impacts on downstream ecosystems and agricultural irrigation during stratification. Moreover, front retaining walls have the advantages of low investment, high safety performance and good construction conditions, so they can be applied to the water temperature management of reservoirs and provide a reference for reservoirs with similar hydraulic conditions.

Input boundary of the model.

(TIF) Click here for additional data file. 24 Jun 2021 PONE-D-21-16906 Study on the effect of front retaining walls on the thermal structure and outflow temperature of reservoirs. PLOS ONE Dear Dr. tuo, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. The paper is interesting and it could be proceeded further after major revision. Please submit your revised manuscript by Aug 08 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Mohammad Mehdi Rashidi Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. Please see the following video for instructions on linking an ORCID iD to your Editorial Manager account: https://www.youtube.com/watch?v=_xcclfuvtxQ 3. Thank you for stating the following in the Competing Interests /Financial Disclosure* (delete as necessary) section: 'The authors have declared that no competing interests exist.' We note that one or more of the authors are employed by a commercial company: PowerChina Guiyang Survey, Design and Research Institute Co. Ltd. Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form. Please also include the following statement within your amended Funding Statement. “The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.” If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement. 2. Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc. Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to  PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and  there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf. Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interests 4. We note that Figure 2 includes an image of a [patient / participant / in the study]. As per the PLOS ONE policy (http://journals.plos.org/plosone/s/submission-guidelines#loc-human-subjects-research) on papers that include identifying, or potentially identifying, information, the individual(s) or parent(s)/guardian(s) must be informed of the terms of the PLOS open-access (CC-BY) license and provide specific permission for publication of these details under the terms of this license. Please download the Consent Form for Publication in a PLOS Journal (http://journals.plos.org/plosone/s/file?id=8ce6/plos-consent-form-english.pdf). The signed consent form should not be submitted with the manuscript, but should be securely filed in the individual's case notes. Please amend the methods section and ethics statement of the manuscript to explicitly state that the patient/participant has provided consent for publication: “The individual in this manuscript has given written informed consent (as outlined in PLOS consent form) to publish these case details”. If you are unable to obtain consent from the subject of the photograph, you will need to remove the figure and any other textual identifying information or case descriptions for this individual. Additional Editor Comments (if provided): [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Title: Study on the effect of front retaining walls on the thermal structure and outflow temperature of reservoirs MS NO. PONE-D-21-16906 In this paper, a two-dimensional hydrodynamic CE-QUALW2 model was established and calibrated to simulate the reservoir and outflow temperature with and without the front retaining wall and its impact on the thermal stability and outflow temperature are obtained. The idea seems interesting and practical; however, the following comments has to be addressed. 1. In the introduction section avoid using lumped citation and discuss the cited papers. 3. Justify why this is a 2D problem rather than a 3D one. 4. Enhance the quality of the figures. 5. Add nomenclature to the paper to enhance readability. 6. Explain why CE-QUAL-W2 model is hired. 7. Clearly justify the mismatch in the verification case. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 11 Aug 2021 We are grateful for the constructive comments and suggestions. Based on your comments, we have revised the relevant content in the manuscript. Firstly, we improved the quality of the introduction including revising the lumped citation, summarizing the results of some academic papers, and further refining and highlighting the innovation of our paper. Secondly, we professionalized the language of the paper, and explained the reason why the dimensions and the specific models were used. Secondly, the figures and formats of the paper were modified to meet the publishing requirements of your journal. Our point-by-point responses to your comments are provided in the Response to Reviewers. Submitted filename: Response to Reviewers.docx Click here for additional data file. 22 Oct 2021 PONE-D-21-16906R1Study on the effect of front retaining walls on the thermal structure and outflow temperature of reservoirs.PLOS ONE Dear Dr. tuo, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Dec 06 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Mohammad Mehdi Rashidi Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Partly ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: N/A ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: All comments have been addressed. Reviewer #2: Here are some comments that author(s) need to respond: 1. Authors need to indicate following information of this research in abstract i) The location of this research, as it is stated in section 2.1, line 85, Dongqing Reservoir located in the southwestern Guizhou Province, China. Authors need to clarify the region of proposed study clearly. ii) The duration of collected data needs to specify, as it is provided in section 2.1, line 102-103, from January to September 2017 2. In section 3.1, results and discussion, line 172-173, authors need to provides the sources of used data in this research. 3. Please clarify that the used critical coefficients in CE-QUAL-W2 model given in Table 1, are from existing research or are fitted in this research, if yes please provide the reference. 4. Section 3.4, Engineering Applications and Prospects for this Study, the provided results in Fig 8 does not present the stated improvement in line 365-370. Authors need to explain it. 5. The quality of figures should be improved. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Touraj Khodadadi [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 2 Nov 2021 Dear reviewer, We are grateful for the constructive comments and suggestions. Based on your comments, we have revised the relevant content in the manuscript. Firstly, we improved the quality of the abstract by adding to the location and duration of observation data in our research. Based on ’your opinion, we provided the source of used data, calibrated the critical coefficients given in our model and further added the cited references. Secondly, we professionalized the language of the paper, and all the figures and formats of the paper were modified to meet the publishing requirements of PLOS ONE. Our point-by-point responses to your comments are provided below. 1): Authors need to indicate following information of this research in abstract: i) The location of this research, as it is stated in section 2.1, line 85, Dongqing Reservoir located in the southwestern Guizhou Province, China. Authors need to clarify the region of proposed study clearly. ii) The duration of collected data needs to specify, as it is provided in section 2.1, line 102-103, from January to September 2017. Response to reviewer’s comment No. 1: Thank you so much for your constructive suggestion. Based on your suggestion, we made relative revisions on Abstract by adding the location and duration of collected data. The sentences correspondingly in line 10-14 of Manuscript was as follows: For this purpose, taking the Dongqing Reservoir (25° 31’N, 105° 46’E) as a case study, a two-dimensional hydrodynamic CE-QUAL-W2 model was configured for the typical channel-type reservoir in the southwestern Guizhou Province, to better understand the influence of FRWs on the thermal structure and outflow temperature. The simulated data from January to September 2017 showed that FRWs can change the vertical temperature distribution during the stratification period, accelerate the upper warmer water release and thus decrease the strength of thermal stratification. 2): In section 3.1, results and discussion, line 172-173, authors need to provides the sources of used data in this research. Response to reviewer’s comment No. 2: Thank you so much for your constructive suggestion. I’m sorry for the expression lacking consideration and thoroughness. Hydrological data was mainly from the operation data from the monitoring of the upstream and downstream power stations of the reservoir. The meteorological data originated from the Zhenfeng Meteorological Station, see line 172-173. Additionally, we added the sources of used data in line 168-169 of Manuscript which was as follows: We compared the calculated results and measured data for upstream of the dam (Fig 2) and outflow temperature (Fig 3) based on hydrological and meteorological data from January to September 15, 2017, which were obtained from the monitoring of the upstream and downstream power station of the Dongqing Reservoir and the meteorological website (http://www.cma.gov.cn/2011qxfw/2011qsjgx/), respectively. 3): Please clarify that the used critical coefficients in CE-QUAL-W2 model given in Table 1, are from existing research or are fitted in this research, if yes please provide the reference. Response to reviewer’s comment No. 3: Thank you for your suggestion. The critical coefficients given in Table 1 include the longitudinal eddy viscosity coefficient, longitudinal eddy diffusion coefficient, wind shielding coefficient, extinction for pure water, solar radiation absorbed in the surface layer and dynamic shading coefficient. Among them, the eddy viscosity coefficients affect the hydrodynamic conditions, which are difficult to calibrate. For the values, we refer to the case of CE-QUAL-W2 user manual [1]. Since the mountains on both sides of the bank don’t obstruct the Dongqing reservoir area, the dynamic shade coefficient and wind shade coefficient are both taken as 1 [2-4]. Therefore, we calibrate eextinctions for pure water (EXH2O) and solar radiation absorbed in the surface layer (BETA). They are related to the chromaticity and turbidity of water bodies. Studies have shown that the value of BETA ranges from 0.4 to 0.7, and EXH2O ranges from 0 to 1 [5]. The values of EXH2O are 0.3 and 0.8 respectively for calibration, and MAE and RMSE are obtained, as shown in Table 1. Similarly, choose BETA to be 0.4 for calibration, and get MAE and RMSE, see Table 2. All the calibration could be carried out under the control variables. Fig 1 and Fig 2 shows comparisons from different EXH2O and BETA in different months. Table 1. Calibration for EXH2O EXH2O MAE AVE RMSE 1 2 3 4 5 6 7 8 9 0.8 0.15 0.25 0.34 0.39 0.55 0.50 0.86 0.71 0.43 0.46 0.69 0.5 0.14 0.25 0.31 0.36 0.49 0.46 0.86 0.69 0.44 0.44 0.63 0.3 0.14 0.25 0.27 0.33 0.54 0.52 0.83 0.70 0.43 0.45 0.64 (a) June 15, 2017 (b) August 15, 2017 Fig 1. Calibration for EXH2O in different months Table 2. Calibration for BETA BETA MAE AVE RMSE 1 2 3 4 5 6 7 8 9 0.40 0.14 0.25 0.28 0.37 0.55 0.48 1.04 0.67 0.52 0.48 0.75 0.65 0.14 0.25 0.31 0.36 0.49 0.46 0.86 0.69 0.44 0.44 0.63 (a) May 15, 2017 (b) September 15, 2017 Fig 2. Calibration for BETA in different months Obviously, when choose 0.5 for EXH2O and 0.65 for BETA, the MAE and RMSE get smaller showing a better verification effect. we added the sources of these parameters in line 162 of Manuscript. Reference: 1. Cole, T.M.; Wells, S.A., 2013. CE-QUAL-W2: A Two-Dimensional, Laterally Averaged, Hydrodynamic and Water Quality Model; Version 3.71; User Manual; Department of Civil and Environmental Engineering, Portland State University: Portland, OR, USA. https://doi:10.1023/b:hydr.0000008504.61773.77 2. Xie, Q., Liu, Z., Fang, X., Chen, Y., Li, C., MacIntyre, S. 2017. Understanding the Temperature Variations and Thermal Structure of a Subtropical Deep River-Run Reservoir before and after Impoundment. Water. 9(8), 603. https://doi.org/10.11660/slfdxb.20190105 3. Yang Y, Deng Y, Tuo Y, Li J, He T, Chen M (2020) Study of the thermal regime of a reservoir on the Qinghai-Tibetan Plateau, China. PLoS ONE 15(12): e0243198. https://doi.org/10.1371/journal.pone.0243198 4. Li, J., Liu, S., Sun, D., Yang, J. 2015. Discussion on the application of CE-QUAL-W2 water temperature model for long and narrow valley reservoirs [C]. 25th Chinese Society For Environmental Sciences Conference. 1652-1658. 5. Deng Y. 2003. Study on the Water Temperature Prediction Model for the Huge and Deep Reservoir. PhD dissertation, Sichuan University. https://kns.cnki.net/KCMS/detail/detail.aspx?dbname=CDFD9908&filename=2004030814.nh 4): Section 3.4, Engineering Applications and Prospects for this Study, the provided results in Fig 8 does not present the stated improvement in line 365-370. Authors need to explain it. Response to reviewer’s comment No. 4: Thank you so much for your suggestion. We have revised Figure 8 by adding to the whole withdrawal elevations from March to September. It can be seen that the minimum elevation is 472.5m in June when there is a front retaining wall before the dam. Usually, the withdrawal layer referring to the layer with the maximum flow rate is recognized as the mean plug layer (Part 3.3.2, line 283). The water level of the Dongqing Reservoir and the elevation of the FRW is mentioned in line 90 and line 120 of Manuscript considerably. Moreover, we reorganized our texts in line 326-329: For example, the water level of the Dongqing reservoir ranges from 484m to 490m. The lowest elevation of the mean plug flow is 472.5 m (June, Fig 8) near the upper thermocline, causing that the upper high-temperature water body can be continuously obtained. Fig 8. Elevations of the withdrawal layer in different months and different working conditions and the local flow field distribution in front of the dam in April, July and September 5): The quality of figures should be improved. Response to reviewer’s comment No. 5: Thank you for your kindly reminder. We complemented all the figures with corresponding parts including enlarging the font, improving the clarity, readability and beauty of the figures. We employed 300dpi of all the figures as output parameter with Adobe Illustrator CC software. And then we upload our figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool to ensure that figures meet PLOS ONE requirements. Once again, thank you for your valuable suggestions and comments that enable us to substantially improve this paper. We hope the corrections will be accepted. Best wishes, Corresponding Author: Associate Prof. Youcai, Tuo 2021-11-2 Submitted filename: Response to Reviewers.docx Click here for additional data file. 17 Nov 2021 Study on the effect of front retaining walls on the thermal structure and outflow temperature of reservoirs. PONE-D-21-16906R2 Dear Dr. tuo, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Mohammad Mehdi Rashidi Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #2: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #2: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #2: (No Response) ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #2: Yes: Touraj khodadadi 1 Dec 2021 PONE-D-21-16906R2 Study on the effect of front retaining walls on the thermal structure and outflow temperature of reservoirs Dear Dr. Tuo: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Professor Mohammad Mehdi Rashidi Academic Editor PLOS ONE
  7 in total

1.  Simulated limnological effects of the Shasta Lake temperature control device.

Authors:  J Bartholow; R B Hanna; L Saito; D Lieberman; M Horn
Journal:  Environ Manage       Date:  2001-04       Impact factor: 3.266

2.  Effects of warm water inflows on the dispersion of pollutants in small reservoirs.

Authors:  María C Palancar; José M Aragón; Fernando Sánchez; Roberto Gil
Journal:  J Environ Manage       Date:  2006-03-30       Impact factor: 6.789

3.  Calibration of CE-QUAL-W2 for a monomictic reservoir in a monsoon climate area.

Authors:  S W Chung; J K Oh
Journal:  Water Sci Technol       Date:  2006       Impact factor: 1.915

4.  Optimizing withdrawal from drinking water reservoirs to reduce downstream temperature pollution and reservoir hypoxia.

Authors:  M Weber; K Rinke; M R Hipsey; B Boehrer
Journal:  J Environ Manage       Date:  2017-03-21       Impact factor: 6.789

5.  Laboratory investigation on the influence of factors on the outflow temperature from stratified reservoir regulated by temperature control curtain.

Authors:  Qinglin Song; Bowen Sun; Xueping Gao; Yinzhu Liu
Journal:  Environ Sci Pollut Res Int       Date:  2020-06-11       Impact factor: 4.223

6.  Dissolved oxygen stratification and response to thermal structure and long-term climate change in a large and deep subtropical reservoir (Lake Qiandaohu, China).

Authors:  Yunlin Zhang; Zhixu Wu; Mingliang Liu; Jianbo He; Kun Shi; Yongqiang Zhou; Mingzhu Wang; Xiaohan Liu
Journal:  Water Res       Date:  2015-03-03       Impact factor: 11.236

7.  Effects of selective withdrawal on hydrodynamics and water quality of a thermally stratified reservoir in the southern side of the Mediterranean Sea: a simulation approach.

Authors:  Besma Zouabi-Aloui; Segun Michael Adelana; Moncef Gueddari
Journal:  Environ Monit Assess       Date:  2015-04-25       Impact factor: 2.513

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.