| Literature DB >> 34879853 |
Cristina Ariadna Nicula1,2, Dorin Nicula2, Sorana D Bolboacă3, Adriana Elena Bulboacă4.
Abstract
PURPOSE: To report the visual and refractive outcomes of small incision lenticule extraction ReLEX (SMILE) technique using VisuMax femtosecond laser in myopia and myopic astigmatism patients.Entities:
Keywords: Femtosecond laser; Myopia; Myopic astigmatism; Small Incision Lenticule Extraction (SMILE)
Mesh:
Year: 2021 PMID: 34879853 PMCID: PMC8656009 DOI: 10.1186/s12886-021-02195-9
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Visual and refractive outcomes, safety and predictability of some recent studies performed on small incision lenticule extraction
| Study | No. of eyes | Duration, years | Spherical equivalent preop | Spherical equivalent postop | Eyes within ±0.5D | UCVA (%) – ≥20/× postop |
|---|---|---|---|---|---|---|
| Sekundo et al 2011 [ | 91 | 0.5 | -4.75±1.56 | -0.01±0.49 | 80 | 84 – 20/20 |
| Shah et al 2011 [ | 51 | 0.5 | -4.87±2.16 | +0.03±0.30 | 91 | 67 – 20/20 |
| Hjortdal et al 2012 [ | 670 | 0.25 | -7.19±1.30 | -0.25±0.44 | 80 | 61 – 20/20 |
| Karmia et al 2014 [ | 26 | 0.5 | -4.21±1.63 | +0.01 | 100 | 96 – 20/20 |
| Aǧca et al 2014 [ | 40 | 1 | -4.03±1.61 | -0.02±0.06 | 95 | 65 – 20/20 |
| Reinstein 2014 [ | 110 | 1 | -2.61±0.54 | -0.05±0.36 | - | 96 – 20/20 |
| Vestergaard 2014 [ | 127 | 0.25 | -7.18±1.57 | -0.09±0.45 | 77 | 37 – 20/20 73 – 20/25 |
| Pedersen et al 2015 [ | 87 | 3 | -7.30±1.40 | -0.40±0.60 | 70 | 49 – 20/25 |
| Chan et al 2015 [ | 54 | 0.17 | -6.05±1.46 | -0.10±0.23 | 98.2 | 76 – 20/25 |
| Wu et al 2016 [ | 39 | 1 | -6.90±0.86 | -0.05±0.33 | 96.7 | 93 – 20/25 |
| Blum et al 2016 [ | 56 | 5 | -4.89±4.97 | -0.375 | 48.2 | n.a. |
| Yildirim et al 2016 [ | 45 | 2 | -7.10±0.95 | -0.30±0.50 | 92 | 86 – 20/20 |
| Han et al 2016 [ | 47 | 2 | -6.30±1.47 | -0.09±0.39 | 89 | 92 – 20/20 |
| Liu et al 2016 [ | 113 | 0.5 | -5.22±1.70 | -0.03±0.13 | 97 | 96 – 20/20 |
| Ganesh et al 2017 [ | 50 | 0.25 | -0.14±0.28 | -0.14±0.28 | 86 | 96 – 20/20 |
| Pietila 2018 [ | 300 | 1 | -4.08±1.65 | 0.04±0.48 | 91 | 80 – 20/20 |
UCVA uncorrected visual acuity, n.a. not available
The settings of the laser
| Parameters | Standard mode |
|---|---|
| Frequency, kHz | 130-135 |
| Energy offset, (1 offset = 5 nJ) | 26-27 |
| Spot distance, μm | |
Lenticule and cap cuts Lenticule and cap side cuts | 4.2-4.3 2 |
| Track distance, μm | |
Lenticule and cap cuts Lenticule and cap side cuts | 4.2-4.3 2 |
Surgical parameters applied in the SMILE technique
| Item | Lenticule | Cap |
|---|---|---|
| Optical zone, mm | 6.5 | |
| Thickness between, μm | 15 | 120-140 |
| Side cut angle, ° | 90 | 90 |
| Transition zone, mm | 0.10 | |
| Diameter, mm | 6.5 | 7.50 |
| Incision position, ° | 90 | |
| Incision width, mm | 3.93 |
Baseline parameters of the group
| Parameter | Value |
|---|---|
| Gender, % | |
Women Men | 57.60 42.40 |
| Spheric equivalent, diopter a | |
Myopic eyes Myopic astigmatic eyes Statistic ( | -4.25 (-5.25 to -3.12) -6.25 (-7.25 to -4.13) 2.97 (0.0031) |
| Mean Keratometry, diopter a | |
Myopic eyes Myopic astigmatic eyes Statistic ( | 43.50 (42.75 to 44.85) 44.20 (43.10 to 45.00) 0.66 (0.5103) |
a values are expressed as the median and interquartile range (Q1 to Q3), where Q1 is the first quartile and Q3 is the third quartile
Fig. 1Refractive stability expressed as MRSE (mean refractive spherical equivalent): a myopic eyes; b myopic astigmatic eyes (m = month)
Fig. 2Refractive outcomes of the group at 12 months postoperatively: a) attempted versus achieved manifest SE correction in diopters on the myopic eyes; b) attempted versus achieved manifest SE correction in diopters on the myopic astigmatic eyes
UDVA and CDVA changes in time: comparisons between baseline and each follow-up
| Myopic eyes | Myopic astigmatic eyes | |||
|---|---|---|---|---|
| Median (Q1 to Q3) | Stat. ( | Median (Q1 to Q3) | Stat. ( | |
| UDVA | ||||
| Baseline | 0.10 (0.10 to 0.20) | 0.10 (0.05 to 0.10) | ||
1 month 6 months 12 months | 0.90 (0.60 to 1.00) 0.90 (0.80 to 1.00) 0.90 (0.80 to 1.00) | 4.20 (0.00003) 4.20 (0.00003) 4.20 (0.00003) | 0.80 (0.50 to 0.90) 0.80 (0.60 to 0.90) 0.80 (0.55 to 0.90) | 7.12 (<0.00001) 7.12 (<0.00001) 7.12 (<0.00001) |
| CDVA | ||||
| Baseline | 1.00 (0.90 to 1.00) | 0.90 (0.70 to 1.00) | ||
1 month 6 months 12 months | 0.90 (0.00 to 1.00) 0.90 (0.00 to 1.00) 0.90 (0.00 to 1.00) | 2.75 (0.0060) 2.75 (0.0060) 2.75 (0.0060) | 0.40 (0.00 to 0.90) 0.40 (0.00 to 0.90) 0.40 (0.00 to 0.90) | 5.06 (<0.00001) 5.05 (<0.00001) 4.95 (<0.00001) |
Q1 first quartile, Q3 third quartile; Comparisons between baseline and each follow-up was done with Wilcoxon test
The safety index and efficacy index expressed as the median and interquartile range (first quartile to the third quartile)
| Index | Myopic eyes | Myopic astigmatic eyes | Mann-Whitney test |
|---|---|---|---|
| Safety index (SI) | |||
1 month 6 months 12 months | 0.90 (0.00 to 1.00) 0.90 (0.00 to 1.00) 0.90 (0.00 to 1.00) | 0.71 (0.00 to 1.00) 0.80 (0.00 to 1.00) 0.80 (0.00 to 1.00) | 0.59 (0.5536) 0.60 (0.5506) 0.43 (0.6640) |
| Efficacy index (EI) | |||
1 month 6 months 12 months | 1.00 (0.60 to 1.00) 1.00 (0.80 to 1.00) 1.00 (0.80 to 1.00) | 1.00 (0.76 to 1.00) 1.00 (0.83 to 1.00) 1.00 (0.83 to 1.00) | -0.80 (0.4245) -0.95 (0.3432) -0.80 (0.4245) |