Literature DB >> 24893355

Lenticule thickness readout for small incision lenticule extraction compared to artemis three-dimensional very high-frequency digital ultrasound stromal measurements.

Dan Z Reinstein, Timothy J Archer, Marine Gobbe.   

Abstract

PURPOSE: To evaluate the accuracy of the lenticule thickness readout for small incision lenticule extraction (SMILE) with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany).
METHODS: Artemis very high-frequency digital ultrasound (ArcScan, Inc., Morrison, CO) measurements were obtained before and 3 months after SMILE in 70 eyes of 37 patients. The Artemis measured lenticule thickness was calculated as the maximum difference in stromal thickness before and after treatment. Comparative statistics and linear regression analysis were performed between the VisuMax readout lenticule thickness and Artemis measured maximum stromal change. Central epithelial thickness was measured and a similar analysis was performed using corneal thickness. Variability of the data were compared to ablation depths for a matched group of eyes from a previously published LASIK population treated with the MEL80 excimer laser (Carl Zeiss Meditec).
RESULTS: The mean maximum myopic meridian treated was -7.81 ± 2.33 diopters (range: -2.25 to -12.50 diopters). On average, the VisuMax readout lenticule depth was 8.2 ± 8.0 μm thicker (range: -8 to +29 μm) than the Artemis measured stromal change (P < .001). On average, central epithelial thickness was 15.0 ± 5.2 μm thicker (range: 5 to 30 μm) after the procedure. The VisuMax readout lenticule thickness was 23.2 ± 10.9 μm thicker (range: +5 to +49 μm) than the Artemis measured corneal thickness change. The R(2) of 0.868 for the SMILE group was higher than 0.738 for the LASIK group (P = .015).
CONCLUSIONS: The accuracy of SMILE lenticule thickness was found to be higher than actual measured stromal thickness change; however, predictability for SMILE lenticule thickness appeared higher than predictability for excimer laser ablation depth. The VisuMax readout lenticule depth was found to be 8 μm thicker than the achieved stromal change. This can be partly explained by alignment errors between preoperative and postoperative scans. However, this appears to show some biomechanical changes occur after SMILE. Copyright 2014, SLACK Incorporated.

Entities:  

Mesh:

Year:  2014        PMID: 24893355     DOI: 10.3928/1081597X-20140416-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

Review 1.  Refractive lenticule extraction small incision lenticule extraction: A new refractive surgery paradigm.

Authors:  Sri Ganesh; Sheetal Brar; Raghavender Reddy Arra
Journal:  Indian J Ophthalmol       Date:  2018-01       Impact factor: 1.848

2.  Evaluation of Wide Corneal Epithelial Remodeling after Small Incision Lenticule Extraction (SMILE) with Wide-Field Optical Coherence Tomography.

Authors:  Yiming Ye; Pei Chen; Na Yu; Linxi Wan; Min Lan; Hua Zheng; Keming Yu
Journal:  J Ophthalmol       Date:  2022-03-20       Impact factor: 1.909

3.  Biomechanical Effects of tPRK, FS-LASIK, and SMILE on the Cornea.

Authors:  Yue Xin; Bernardo T Lopes; JunJie Wang; Jie Wu; ManMan Zhu; MuChen Jiang; YuanYuan Miao; HuiNi Lin; Si Cao; XiaoBo Zheng; Ashkan Eliasy; ShiHao Chen; QinMei Wang; YuFeng Ye; FangJun Bao; Ahmed Elsheikh
Journal:  Front Bioeng Biotechnol       Date:  2022-03-31

Review 4.  Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe
Journal:  Eye Vis (Lond)       Date:  2014-10-16

5.  Small Incision Lenticule Extraction for Postkeratoplasty Myopia and Astigmatism.

Authors:  Tamer H Massoud; Osama Ibrahim; Kitty Shehata; Moones F Abdalla
Journal:  J Ophthalmol       Date:  2016-06-30       Impact factor: 1.909

6.  Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery.

Authors:  Pinghui Wei; George Pm Cheng; Jiamei Zhang; Alex Lk Ng; Tommy Cy Chan; Vishal Jhanji; Yan Wang
Journal:  J Ophthalmol       Date:  2020-04-27       Impact factor: 1.909

7.  Investigation of predictability and influence factors of the achieved lenticule thickness in small incision lenticule extraction.

Authors:  Fang Wu; Houfa Yin; Xinyi Chen; Yabo Yang
Journal:  BMC Ophthalmol       Date:  2020-03-17       Impact factor: 2.209

8.  One year outcomes after small incision lenticule extraction ReLEX in the correction of myopia and myopic astigmatism.

Authors:  Cristina Ariadna Nicula; Dorin Nicula; Sorana D Bolboacă; Adriana Elena Bulboacă
Journal:  BMC Ophthalmol       Date:  2021-12-08       Impact factor: 2.209

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.