Literature DB >> 3487261

Poor correlation between pulmonary arterial wedge pressure and left ventricular end-diastolic volume after coronary artery bypass graft surgery.

R M Hansen, C E Viquerat, M A Matthay, J P Wiener-Kronish, T DeMarco, S Bahtia, J D Marks, E H Botvinick, K Chatterjee.   

Abstract

The authors studied 12 surgical patients in the intensive care unit post coronary artery bypass graft surgery and ten nonsurgical patients in the coronary care unit with chronic heart failure to determine the usefulness of the pulmonary arterial wedge pressure as an indicator of left ventricular preload. Left ventricular end diastolic volume was derived from concomitant determination of ejection fraction (gated blood pool scintigraphy) and stroke volume (determined from thermodilution cardiac output). In the nonsurgical patients, there was a significant correlation between changes in pulmonary arterial wedge pressure and left ventricular end-diastolic volume (P less than 0.05, r = 0.57). In the 12 patients studied during the first few hours after surgery, there was a poor correlation between changes in pulmonary wedge pressure (range = 4-32 mmHg) and left ventricular end-diastolic volume (range = 25-119 ml/m2), and a poor correlation between pulmonary arterial wedge pressures and stroke work index. In contrast, there was a good correlation between left ventricular end-diastolic volume and stroke work index. The poor correlation between the pulmonary arterial wedge pressure and left ventricular end-diastolic volume was not explained by changes in systemic or pulmonary vascular resistance. The altered ventricular pressure-volume relationship may reflect acute changes in ventricular compliance in the first few hours following coronary artery bypass graft surgery. While measurement of pulmonary arterial wedge pressure remains valuable in clinical management to avoid pulmonary edema, it cannot reliably be used as an index of left ventricular preload while attempting to optimize stroke volume in patients immediately following coronary artery bypass graft surgery.

Entities:  

Mesh:

Year:  1986        PMID: 3487261     DOI: 10.1097/00000542-198606000-00015

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  12 in total

1.  Using ventilation-induced aortic pressure and flow variation to diagnose preload responsiveness.

Authors:  Michael R Pinsky
Journal:  Intensive Care Med       Date:  2004-03-06       Impact factor: 17.440

2.  Methods of monitoring shock.

Authors:  Ednan K Bajwa; Atul Malhotra; B Taylor Thompson
Journal:  Semin Respir Crit Care Med       Date:  2004-12       Impact factor: 3.119

Review 3.  Hemodynamic monitoring during liver transplantation: A state of the art review.

Authors:  Mona Rezai Rudnick; Lorenzo De Marchi; Jeffrey S Plotkin
Journal:  World J Hepatol       Date:  2015-06-08

4.  Value of impedance cardiography in patients studied for pulmonary hypertension.

Authors:  Adriano R Tonelli; Hassan Alnuaimat; Ning Li; Robin Carrie; Kamal K Mubarak
Journal:  Lung       Date:  2011-05-24       Impact factor: 2.584

5.  Postoperative haemodynamic and pharmacological responses in patients with positive technetium pyrophosphate single-photon emission computed tomography following CABG.

Authors:  D C Cheng; R J Burns; F Chung; A Chung; C M Feindel
Journal:  Can J Anaesth       Date:  1992-01       Impact factor: 5.063

6.  Comparison of two methods for enhanced continuous circulatory monitoring in patients with septic shock.

Authors:  F Spöhr; P Hettrich; H Bauer; U Haas; E Martin; B W Böttiger
Journal:  Intensive Care Med       Date:  2007-06-05       Impact factor: 17.440

7.  Perioperative intravascular fluid assessment and monitoring: a narrative review of established and emerging techniques.

Authors:  Sumit Singh; Ware G Kuschner; Geoffrey Lighthall
Journal:  Anesthesiol Res Pract       Date:  2011-07-12

Review 8.  Transesophageal two-dimensional echocardiography in the critically ill--is the Swan-Ganz catheter redundant?

Authors:  T D Rafferty
Journal:  Yale J Biol Med       Date:  1991 Jul-Aug

Review 9.  Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?

Authors:  A C Perrino
Journal:  Yale J Biol Med       Date:  1993 Sep-Oct

10.  Brachial artery flow velocity variation: another victory for hand-carried ultrasound?

Authors:  Gregory A Schmidt
Journal:  Crit Care       Date:  2009-10-16       Impact factor: 9.097

View more