Literature DB >> 3484915

Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans.

B Kleinman, R E Henkin, S N Glisson, A A el-Etr, M Bakhos, H J Sullivan, A Montoya, R Pifarre.   

Abstract

Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3484915     DOI: 10.1097/00000542-198602000-00005

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

1.  Pharmacology of the coronary circulation.

Authors:  J C Sill
Journal:  Can J Anaesth       Date:  1987-05       Impact factor: 5.063

Review 2.  Perioperative myocardial ischaemia.

Authors:  I R Thomson
Journal:  Can J Anaesth       Date:  1989-05       Impact factor: 5.063

3.  Abstracts: annual meeting of the Canadian Anesthetists' Society. June 26-29, 1988, Halifax, Nova Scotia.

Authors: 
Journal:  Can J Anaesth       Date:  1988-05       Impact factor: 5.063

Review 4.  Myocardial scintigraphy--25 years after start.

Authors:  G Hör
Journal:  Eur J Nucl Med       Date:  1988

5.  Detection of intraoperative myocardial ischaemia--a comparison among electrocardiographic, myocardial metabolic, and haemodynamic measurements in patients with reduced ventricular function.

Authors:  R I Hall; N O'Regan; M Gardner
Journal:  Can J Anaesth       Date:  1995-06       Impact factor: 5.063

6.  Failure to predict intraoperative myocardial ischaemia in patients with coronary artery disease.

Authors:  H Smith; H Nathan; M Harrison
Journal:  Can J Anaesth       Date:  1989-09       Impact factor: 5.063

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.