Literature DB >> 34812784

Effects of Type 2 Diabetes Mellitus and Smoking on Changes in Corneal Endothelial Morphology and Cell Density.

Marija Antičić-Eichwalder1, Susanne Lex1, Stephanie Sarny1, Jakob Schweighofer1, Ivana Marić2, Yosuf El-Shabrawi1.   

Abstract

PURPOSE: The purpose of this study was to compare the corneal endothelial morphology and cell density of diabetic smokers and nonsmokers with 50 to 70 age-matched healthy subjects and to determine whether smoking increases the effects of type 2 diabetes mellitus (DM) on these corneal parameters.
METHODS: This prospective cohort study included 200 patients who were assigned to 4 groups, including smokers with type 2 DM (group 1), nonsmokers with type 2 DM (group 2), healthy smokers (group 3), and healthy nonsmokers (control group, group 4). Noncontact specular microscopy was used to measure central endothelial cell density (ECD), coefficient of variation of cell area, percentage of hexagonal cells, and central corneal pachymetry (CCT).
RESULTS: According to the ECD and CCT values ( P < 0.001 and P = 0.013, respectively), a significant difference was observed between the groups. The mean ECD was lowest in diabetic smokers (1917 ± 399 cells/mm 2 ). Healthy smokers and diabetic smokers had significantly lower ECD compared with the control group ( P = 0.03 and P < 0.001, respectively). Healthy smokers and diabetic smokers had significantly lower ECD compared with diabetic nonsmokers ( P = 0.012 and P < 0.001, respectively). The cornea was significantly thicker in the diabetic smokers than in the control group ( P = 0.013).
CONCLUSIONS: The coexistence of DM and smoking causes a significant decrease in ECD and an increase in CCT. Cigarette smoking is more harmful to corneal endothelial cells than DM alone.
Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc.

Entities:  

Mesh:

Year:  2021        PMID: 34812784      PMCID: PMC9473709          DOI: 10.1097/ICO.0000000000002917

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   3.152


  31 in total

Review 1.  Risk of smoking in thyroid-associated orbitopathy.

Authors:  K Mann
Journal:  Exp Clin Endocrinol Diabetes       Date:  1999       Impact factor: 2.949

Review 2.  Smoking and Eye Pathologies. A Systemic Review. Part II. Retina Diseases, Uveitis, Optic Neuropathies, Thyroid-Associated Orbitopathy.

Authors:  Małgorzata Nita; Andrzej Grzybowski
Journal:  Curr Pharm Des       Date:  2017       Impact factor: 3.116

3.  Influence of tobacco use on cataract development.

Authors:  P Raju; R George; S Ve Ramesh; H Arvind; M Baskaran; L Vijaya
Journal:  Br J Ophthalmol       Date:  2006-07-12       Impact factor: 4.638

4.  Early Treatment Diabetic Retinopathy Study design and baseline patient characteristics. ETDRS report number 7.

Authors: 
Journal:  Ophthalmology       Date:  1991-05       Impact factor: 12.079

5.  Corneal endothelium evaluation in type I and type II diabetes mellitus.

Authors:  A M Roszkowska; C G Tringali; P Colosi; C A Squeri; G Ferreri
Journal:  Ophthalmologica       Date:  1999       Impact factor: 3.250

6.  Corneal changes in type II diabetes mellitus in Malaysia.

Authors:  Mm Choo; K Prakash; A Samsudin; T Soong; N Ramli; Aj Kadir
Journal:  Int J Ophthalmol       Date:  2010-09-18       Impact factor: 1.779

7.  Changes in the corneal endothelial cell density and morphology in patients with type 2 diabetes mellitus: a population-based study, Sankara Nethralaya Diabetic Retinopathy and Molecular Genetics Study (SN-DREAMS, Report 23).

Authors:  Rachapalle R Sudhir; Rajiv Raman; Tarun Sharma
Journal:  Cornea       Date:  2012-10       Impact factor: 2.651

8.  Prevalence and risk factors for cornea guttata in the Reykjavik Eye Study.

Authors:  Gunnar M Zoega; Aya Fujisawa; Hiroshi Sasaki; Akiko Kubota; Kazuyuki Sasaki; Kazuko Kitagawa; Fridbert Jonasson
Journal:  Ophthalmology       Date:  2006-04       Impact factor: 12.079

9.  Impact of vital signs screening & clinician prompting on alcohol and tobacco screening and intervention rates: a pre-post intervention comparison.

Authors:  J Paul Seale; Sylvia Shellenberger; Mary M Velasquez; John M Boltri; Ike Okosun; Monique Guyinn; Dan Vinson; Monica Cornelius; J Aaron Johnson
Journal:  BMC Fam Pract       Date:  2010-03-05       Impact factor: 2.497

10.  Comparison of the precision of the Topcon SP-3000P specular microscope and an ultrasound pachymeter.

Authors:  Turki M Almubrad; Uchechukwu L Osuagwu; Ibrahim Alabbadi; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2011-06-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.