Weifeng Lu1,2, Lili Tu2,3, Danxuan Xie2,4, Fu Yao2,4, Li Lin2,4, Ying Li2,4, Dexin Li2,5, Chengjin Mou2,4. 1. Department of Anesthesia Surgery Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China. 2. Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China. 3. Department of Geriatric Endocrinology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China. 4. Department of Thyroid and Breast Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China. 5. Department of Hepatobiliary Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China.
Abstract
BACKGROUND: In recent years, according to global statistics, breast cancer is the main disease affecting women. Ultrasound-guided vacuum-assisted biopsy (VAB) has become a frequently used method for breast cancer detection because of its accuracy, simplicity, and fewer complications. METHODS: In PubMed, Medline, EMbase and Cochrane central register of controlled trials, the retrieval time was from the establishment of the database to March 2021, and the keywords included breast tumor, breast cancer-related diseases, breast lesions, vacuum-assisted breast biopsy, sensitivity and specificity. Meta-analysis was performed using RevMan5.3 software provided by the Cochrane Collaboration. RESULTS: A total of 10 articles were included using a random-effects model that pooled the sensitivity, specificity, and other accuracy measures of VAB. The summary receiver operating characteristic (SROC) characteristic curve was used to summarize the overall accuracy. The sensitivity range was 0.94 to 1.00 (mean, 0.981; 95% CI, 0.972-0.987) with a specificity range of 0.87-1.00 (mean, 0.999; 95% CI, 0.997-0.999). The preoperative platelet-lymphocyte ratio (PLR) was 93.84 (95% CI, 41.55-211.95), the neutrophil to lymphocyte ratio (NLR) was 0.05 (95% CI, 0.03-0.09), the sensitivity and specificity of χ2 were 37.10 (P=0.011) and 32.00 (P=0.043), respectively, while those of PLR, NLR, and duration of response (DOR) were 46.98 (P=0.001), 54.92 (P=0.001), and 43.49 (P=0.002), respectively. Differences were considerable. DISCUSSION: In this meta-analysis, a total of 10 articles were included. VAB is an accurate type of biopsy to detect female breast cancer. The results of the meta-analysis were stable, and VAB had high sensitivity (98%) and specificity (nearly 100%). 2021 Gland Surgery. All rights reserved.
BACKGROUND: In recent years, according to global statistics, breast cancer is the main disease affecting women. Ultrasound-guided vacuum-assisted biopsy (VAB) has become a frequently used method for breast cancer detection because of its accuracy, simplicity, and fewer complications. METHODS: In PubMed, Medline, EMbase and Cochrane central register of controlled trials, the retrieval time was from the establishment of the database to March 2021, and the keywords included breast tumor, breast cancer-related diseases, breast lesions, vacuum-assisted breast biopsy, sensitivity and specificity. Meta-analysis was performed using RevMan5.3 software provided by the Cochrane Collaboration. RESULTS: A total of 10 articles were included using a random-effects model that pooled the sensitivity, specificity, and other accuracy measures of VAB. The summary receiver operating characteristic (SROC) characteristic curve was used to summarize the overall accuracy. The sensitivity range was 0.94 to 1.00 (mean, 0.981; 95% CI, 0.972-0.987) with a specificity range of 0.87-1.00 (mean, 0.999; 95% CI, 0.997-0.999). The preoperative platelet-lymphocyte ratio (PLR) was 93.84 (95% CI, 41.55-211.95), the neutrophil to lymphocyte ratio (NLR) was 0.05 (95% CI, 0.03-0.09), the sensitivity and specificity of χ2 were 37.10 (P=0.011) and 32.00 (P=0.043), respectively, while those of PLR, NLR, and duration of response (DOR) were 46.98 (P=0.001), 54.92 (P=0.001), and 43.49 (P=0.002), respectively. Differences were considerable. DISCUSSION: In this meta-analysis, a total of 10 articles were included. VAB is an accurate type of biopsy to detect female breast cancer. The results of the meta-analysis were stable, and VAB had high sensitivity (98%) and specificity (nearly 100%). 2021 Gland Surgery. All rights reserved.
Entities:
Keywords:
Breast cancer; meta-analysis; ultrasonic; vacuum-assisted biopsy (VAB)
Authors: E D Pisano; L L Fajardo; J Tsimikas; N Sneige; W J Frable; C A Gatsonis; W P Evans; I Tocino; B J McNeil Journal: Cancer Date: 1998-02-15 Impact factor: 6.860
Authors: L Liberman; D D Dershaw; J R Glassman; A F Abramson; E A Morris; L R LaTrenta; P P Rosen Journal: Radiology Date: 1997-04 Impact factor: 11.105
Authors: Freddie Bray; Jacques Ferlay; Isabelle Soerjomataram; Rebecca L Siegel; Lindsey A Torre; Ahmedin Jemal Journal: CA Cancer J Clin Date: 2018-09-12 Impact factor: 508.702
Authors: Hua Sun Kim; Min Jung Kim; Eun Kyung Kim; Jin Young Kwak; Eun Ju Son; Ki Keun Oh Journal: Korean J Radiol Date: 2008 Nov-Dec Impact factor: 3.500