Characterisation of in-room leakage and scattered radiation for the Varian Halcyon linear accelerator.

Kirstie Caravani1, Rebecca Murry2, Brendan Healy3.   

Abstract

Unintended sources of secondary radiation resulting from photon beams in linear accelerators are patient scatter, collimator scatter, scatter from surfaces within the bunker, and head leakage. This work characterises the in-room leakage and scattered radiation for the Varian Halcyon linear accelerator. Scattered and leakage radiation for static gantry angles 0°, 45°, and 90° and largest field size 28 × 28 cm2 were measured with an ionisation chamber survey meter at a radial distance of 1.5 m from the isocentre. The scatter within the treatment room was characterised with isocontour maps from measurements of 360° arc deliveries with the largest field size 28 × 28 cm2 at various heights and distances from the isocentre. The transmission through the primary beam stopper was measured with a Farmer ionisation chamber. For static gantry angles, instantaneous dose rate readings were typically around 70 mSv/hr at 1.5 m from the isocentre with lower dose rates at room angles adjacent to the gantry. The head leakage was measured as less than 0.03% of the useful beam. In a full 360° arc, the radiation dose around the Halcyon was coldest in lateral areas, with hotter areas behind and in front of the gantry. The primary beam stopper transmission was measured as 0.019%, reducing the requirement of primary barriers in the shielding design by a factor of 1/500. The results presented in this study can be used to determine the out-of-field dose to patients and to inform bunker shielding designs for Halcyon linear accelerators.
© 2021. Australasian College of Physical Scientists and Engineers in Medicine.

Entities:  

Keywords:  Head leakage; Linear accelerator; Out-of-field dose; Patient scatter

Mesh:

Year:  2021        PMID: 34797532     DOI: 10.1007/s13246-021-01084-1

Source DB:  PubMed          Journal:  Phys Eng Sci Med        ISSN: 2662-4729


  7 in total

1.  Establishment of scatter factors for use in shielding calculations and risk assessment for computed tomography facilities.

Authors:  H Wallace; C J Martin; D G Sutton; D Peet; J R Williams
Journal:  J Radiol Prot       Date:  2012-02-10       Impact factor: 1.394

2.  Helical tomotherapy radiation leakage and shielding considerations.

Authors:  John Balog; Dan Lucas; Cleber DeSouza; Rick Crilly
Journal:  Med Phys       Date:  2005-03       Impact factor: 4.071

3.  Shielding requirements in helical tomotherapy.

Authors:  S Baechler; F O Bochud; D Verellen; R Moeckli
Journal:  Phys Med Biol       Date:  2007-08-01       Impact factor: 3.609

4.  Technical Note: Self-shielding evaluation and radiation leakage measurement of a jawless ring gantry linac with a beam stopper.

Authors:  Bin Cai; Eric Laugeman; HsinLu Hsu; Olga Green; Nels Knutson; S Murty Goddu; Sasa Mutic; Shuhua Du; Lauren Henke; Hyun Kim; Geoffrey D Hugo
Journal:  Med Phys       Date:  2021-04-09       Impact factor: 4.071

5.  AAPM TG 158: Measurement and calculation of doses outside the treated volume from external-beam radiation therapy.

Authors:  Stephen F Kry; Bryan Bednarz; Rebecca M Howell; Larry Dauer; David Followill; Eric Klein; Harald Paganetti; Brian Wang; Cheng-Shie Wuu; X George Xu
Journal:  Med Phys       Date:  2017-08-20       Impact factor: 4.071

6.  Characterization of the HalcyonTM multileaf collimator system.

Authors:  Tze Yee Lim; Irena Dragojević; David Hoffman; Everardo Flores-Martinez; Gwe-Ya Kim
Journal:  J Appl Clin Med Phys       Date:  2019-03-19       Impact factor: 2.102

7.  Dosimetric Characterization of the Dual Layer MLC System for an O-Ring Linear Accelerator.

Authors:  Michele M Kim; Douglas Bollinger; Chris Kennedy; Wei Zou; Ryan Scheuermann; Boon-Keng Kevin Teo; James M Metz; Lei Dong; Taoran Li
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.