| Literature DB >> 34789864 |
Hassan Hashemi1, Soheila Asgari2, Parsa Panahi3, Shiva Mehravaran4, Akbar Fotouhi5, Renato Ambrósio6,7,8.
Abstract
In this study, corneal findings regarding keratoconus (KC) and early KC among mothers with Down syndrome children (MDS) and a group of age-at-delivery-matched mothers with normal children (MNC) were compared. KC was diagnosed based on the presence of a clinical sign and at least one abnormal tomographic or biomechanical criterion. Early KC was defined as having no clinical sign in the presence of at least one abnormal tomographic or biomechanical criterion. The normal subgroups in each group were compared in terms tomographic and biomechanical parameters. In MDS and MNC, the prevalence rates were 6.5% and 1.6% for KC (P = 0.047), and 30.9% and 14.3% for early KC (P = 0.014), respectively. Comparison between the two normal subgroups showed significant differences in mean index of height asymmetry, irregularity index, anterior asphericity, pentacam random forest index, corneal stiffness parameters at first applanation, deformation amplitude ratios, integrated radius-1 mm, highest concavity deflection amplitude, biomechanical corrected IOP, peak distance, and radius (all P < 0.05). This study showed that MDS are more likely to have KC and also to have thinner, steeper and softer corneas compared to MNC. This results support the need for further work for determining the risk of delivering a child with DS.Entities:
Mesh:
Year: 2021 PMID: 34789864 PMCID: PMC8599422 DOI: 10.1038/s41598-021-02035-2
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Mean ± standard deviation of vision, refraction, tomographic and biomechanical indices in mothers with Down syndrome children (MDS) with normal cornea and mothers with normal children (MNC) with normal cornea.
| MDS | MNC | P-value* | |
|---|---|---|---|
| Number of eyes | 84 | 106 | |
| Age at the time of examinations | 48.08 ± 6.61 | 48.93 ± 8.60 | |
| Maternal age at birth | 30.74 ± 6.67 | 30.25 ± 5.11 | |
| UDVA (LogMar) | 0.21 ± 0.35 | 0.26 ± 0.35 | 0.360 |
| CDVA (LogMar) | 0.01 ± 0.03 | 0.01 ± 0.04 | 0.621 |
| SE (D) | 0.01 ± 1.88 | 0.25 ± 1.58 | 0.330 |
| Astigmatism (D) | − 0.69 ± 0.58 | − 0.69 ± 0.54 | 0.963 |
| MCT (µm) | 542.40 ± 27.04 | 543.20 ± 32.05 | 0.845 |
| BAD-D | 0.90 ± 0.60 | 0.91 ± 0.57 | 0.877 |
| ART-max | 463.78 ± 86.48 | 461.21 ± 83.92 | 0.836 |
| Zonal Kmax (D) | 44.26 ± 1.55 | 44.42 ± 1.34 | 0.460 |
| I–S value (D) | 0.13 ± 0.57 | 0.08 ± 0.54 | 0.599 |
| ARC (mm) | 7.71 ± 0.26 | 7.69 ± 0.24 | 0.471 |
| PRC (mm) | 6.29 ± 0.26 | 6.25 ± 0.20 | 0.232 |
| ISV | 14.95 ± 4.82 | 14.65 ± 4.20 | 0.643 |
| IVA | 0.106 ± 0.046 | 0.111 ± 0.044 | 0.420 |
| KI | 1.022 ± 0.021 | 1.019 ± 0.018 | 0.272 |
| CKI | 1.003 ± 0.005 | 1.003 ± 0.006 | 0.921 |
| IHA | 3.78 ± 3.86 | 4.72 ± 4.00 | |
| IHD | 0.009 ± 0.005 | 0.010 ± 0.005 | 0.218 |
| AE-TP_8mmBFS | 1.83 ± 1.47 | 1.81 ± 1.55 | 0.941 |
| PE-TP_8mmBFS | 7.40 ± 4.13 | 7.40 ± 3.25 | 0.999 |
| Irregularity | 0.020 ± 0.007 | 0.018 ± 0.006 | |
| Anterior Q-value | − 0.32 ± 0.12 | − 0.28 ± 0.10 | |
| Posterior Q-value | − 0.30 ± 0.16 | − 0.27 ± 0.14 | 0.184 |
| PRFI | 0.07 ± .10 | 0.05 ± 0.05 | |
| TBI | 0.14 ± 0.19 | 0.13 ± 0.17 | 0.726 |
| SP-A1 (mmHg/mm) | 114.67 ± 23.68 | 117.74 ± 22.28 | |
| DA ratio-1 mm (mm) | 1.59 ± 0.06 | 1.57 ± 0.05 | |
| DA ratio-2 mm (mm) | 4.28 ± 0.50 | 4.09 ± 0.37 | |
| Integrated radius-1 mm (mm) | 6.70 ± 0.85 | 7.02 ± 0.95 | |
| HC Deform. Amp (mm) | 0.97 ± 0.09 | 0.96 ± 0.09 | 0.325 |
| HC Deflec. Amp (mm) | 0.84 ± 0.09 | 0.81 ± 0.12 | |
| bIOP (mmHg) | 15.36 ± 2.20 | 16.04 ± 2.48 | |
| PD (mm) | 4.89 ± 0.28 | 4.78 ± 0.28 | |
| Radius (mm) | 8.71 ± 1.02 | 8.15 ± 1.04 | < |
Significant values are in bold.
MCT minimum corneal thickness, BAD-D Belin Ambrósio display-total deviation, ART-max maximum Ambrósio's relational thickness, K keratometry, I–S inferior–superior asymmetry, ARC anterior radius of curvature, PRC posterior radius of curvature, ISV index of surface variance, IVA index of vertical asymmetry, KI keratoconus index, CKI central KI, IHA index of height asymmetry, IHD index of height decentration, AE-TP_8mmBFS anterior elevation at the thinnest point considering 8 mm best-fit-sphere, PE-TP_8mmBFS posterior elevation at the thinnest point considering 8 mm best-fit-sphere, PRFI Pentacam random forest index, TBI tomographic biomechanical index, SP-A1 stiffness parameters at 1st applanation, DA ratio-1 mm deformation amplitude ratio at 1 mm, DA ratio-2 mm deformation amplitude ratio at 2 mm, HC Deform. Amp highest concavity deformation amplitude, HC Deflec. Amp highest concavity deflection amplitude, bIOP biomechanical intraocular pressure, PD peak distance, UDVA uncorrected distance visual acuity, CDVA corrected distance visual acuity, SE spherical equivalent.