Effect of night dentures on tooth mobility in denture wearers with sleep bruxism: A pilot randomized controlled trial.

Hirofumi Uchida1, Junichiro Wada1, Chie Watanabe2, Tomiharu Nagayama1, Koji Mizutani3, Risako Mikami3, Shusuke Inukai1, Noriyuki Wakabayashi1.   

Abstract

PURPOSE: The purpose of this study was to investigate the inhibitory effect of night denture (ND) placement on abutment tooth mobility in removable partial denture (RPD) wearers with sleep bruxism (SB).
METHODS: The participants were selected from RPD wearers diagnosed with SB using BiteStrip® and randomly allocated to one of the following groups: with ND placement or without ND placement (intervention or control group, respectively). The mobility of the RPD abutment tooth was measured using Periotest® at baseline (T0) and at 1 (T1), 3 (T3), and 6 months (T6). BiteStrip® scores were recorded at T0 and T6. Intragroup comparisons of the Periotest® value (PTV) were performed using analysis of covariance. Intergroup comparisons of PTV and BiteStrip® scores were performed using the linear mixed model and Wilcoxon signed-rank test, respectively. Intragroup comparisons of BiteStrip® scores were performed using the Mann-Whitney U test.
RESULTS: At T6, the PTV in the intervention group was significantly lower than that in the control group (p=0.004). PTV was significantly lower at T6 than that at T0 in the intervention group (p=0.030), while PTV was significantly higher at T6 than that at T0 in the control group (p=0.007). There was no significant difference in the BiteStrip® score between the two groups. The BiteStrip® score at T6 was significantly lower than that at T0 only in the intervention group (p=0.011).
CONCLUSION: ND placement might inhibit the increase in mobility of RPD abutment teeth and be effective in protecting them in RPD wearers with SB.

Entities:  

Keywords:  Abutment tooth; Night denture; Removable partial denture; Sleep bruxism; Tooth mobility

Mesh:

Year:  2021        PMID: 34789636     DOI: 10.2186/jpr.JPR_D_21_00230

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.338


  1 in total

1.  Effect of Nitrogen Gas Post-Curing and Printer Type on the Mechanical Properties of 3D-Printed Hard Occlusal Splint Material.

Authors:  Junichiro Wada; Kanae Wada; Mona Gibreel; Noriyuki Wakabayashi; Tsutomu Iwamoto; Pekka K Vallittu; Lippo Lassila
Journal:  Polymers (Basel)       Date:  2022-09-22       Impact factor: 4.967