Literature DB >> 34781211

Reproducibility of pathologic scoring systems for periprosthetic adverse local tissue reactions: A cross-sectional study.

Thomas W Bauer1, Yaxia Zhang2, Madeleine A Gao3, Bin Q Lin4, Matthew F Koff5.   

Abstract

BACKGROUND: Several previous studies have described broad histologic classifications of peri-prosthetic reactions that likely reflect the underlying mechanism of arthroplasty failure; however, a consensus has not yet been reached about the relative importance of individual observations. QUESTION/
PURPOSE: The purpose of this study was to evaluate the inter-examiner repeatability of commonly used histopathologic grading methods, and to determine the utility of assigning a more simple, global categorization in patients undergoing revision THA surgery of implants with a variety of bearing combinations.
METHODS: Between March 2013 and February 2020, a total of 2131 patients underwent revision hip arthroplasty surgery at a one center, of which 12% (248 of 2131) of patients were enrolled. Two pathologists independently reviewed microscope slides of periprosthetic tissue from these patients, of which 425 slides (229 hips, 222 subjects) were reviewed by both pathologists. Separate slides were used for a priori training of the pathologists. Slides were evaluated with the Campbell Aseptic Lymphocyte-dominant Vasculitis-Associated Lesion (ALVAL) score, the Oxford ALVAL score as modified by Grammatopolous, the Fujishiro and Natu scores, and a proposed simplified pattern classification, similar to that of Krenn et al., that incorporates individual factors of these existing scoring methods and was previously shown to correspond to Magnetic Resonance Imaging findings. Inter-rater agreement was assessed using Gwet's AC1 and AC2 coefficients and correspondence analysis was used to examine associations between individual factors of prior scoring methods with the proposed major pattern.
RESULTS: Almost perfect inter-rater repeatability (Gwet's AC2 > 0.8) was found for 71% (15/21) of the individual factors, and substantial interrater agreement was found for the proposed major overall pattern (Gwet's AC1: 0.80, 95%CI: 0.72-0.85). Correspondence analysis was able to explain 89-91% of data variability and was able to identify individual features not commonly associated with a major pattern, but discriminatory of the major pattern, such as "Lymph Cuff Thickness 0.25-0.5″ with ALVAL.
CONCLUSION: In contrast to prior examinations, excellent interrater agreement was found that may be attributable to a priori training of raters with a test set of slides or difficulty of interpreting grading criteria. The proposed simplified major pattern classification may facilitate evaluation of histopathologic tissue samples.
Copyright © 2021 Elsevier GmbH. All rights reserved.

Entities:  

Keywords:  ALTR; ALVAL; Histopathology; Particles; THA

Mesh:

Year:  2021        PMID: 34781211      PMCID: PMC8690975          DOI: 10.1016/j.prp.2021.153685

Source DB:  PubMed          Journal:  Pathol Res Pract        ISSN: 0344-0338            Impact factor:   3.250


  15 in total

1.  The correlation of wear with histological features after failed hip resurfacing arthroplasty.

Authors:  George Grammatopoulos; Hemant Pandit; Amir Kamali; Francesca Maggiani; Sion Glyn-Jones; Harinderjit S Gill; David W Murray; Nicholas Athanasou
Journal:  J Bone Joint Surg Am       Date:  2013-06-19       Impact factor: 5.284

Review 2.  Revised histopathological consensus classification of joint implant related pathology.

Authors:  V Krenn; L Morawietz; G Perino; H Kienapfel; R Ascherl; G J Hassenpflug; M Thomsen; P Thomas; M Huber; D Kendoff; D Baumhoer; M G Krukemeyer; S Natu; F Boettner; J Zustin; B Kölbel; W Rüther; J P Kretzer; A Tiemann; A Trampuz; L Frommelt; R Tichilow; S Söder; S Müller; J Parvizi; U Illgner; T Gehrke
Journal:  Pathol Res Pract       Date:  2014-10-17       Impact factor: 3.250

3.  CORR Insights®: Current Pathologic Scoring Systems for Metal-on-metal THA Revisions are not Reproducible.

Authors:  Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2017-09-27       Impact factor: 4.176

4.  Combined use of band ligation and detachable snares (endoloop) in a patient with blue rubber bleb nevus syndrome.

Authors:  Anastasios Grammatopoulos; Kalliopi Petraki; George Katsoras
Journal:  Ann Gastroenterol       Date:  2013

5.  Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study.

Authors:  Hans-Georg Willert; Gottfried H Buchhorn; Afshin Fayyazi; Renata Flury; Markus Windler; Georg Köster; Christoph H Lohmann
Journal:  J Bone Joint Surg Am       Date:  2005-01       Impact factor: 5.284

6.  An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements.

Authors:  A P Davies; H G Willert; P A Campbell; I D Learmonth; C P Case
Journal:  J Bone Joint Surg Am       Date:  2005-01       Impact factor: 5.284

7.  Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties.

Authors:  Gayana Mahendra; Hemant Pandit; Karolina Kliskey; David Murray; Harinderjit Singh Gill; Nick Athanasou
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

8.  Histological features of pseudotumor-like tissues from metal-on-metal hips.

Authors:  Pat Campbell; Edward Ebramzadeh; Scott Nelson; Karren Takamura; Koen De Smet; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

9.  Correspondence analysis is a useful tool to uncover the relationships among categorical variables.

Authors:  Nadia Sourial; Christina Wolfson; Bin Zhu; Jacqueline Quail; John Fletcher; Sathya Karunananthan; Karen Bandeen-Roche; François Béland; Howard Bergman
Journal:  J Clin Epidemiol       Date:  2009-11-06       Impact factor: 6.437

10.  Perivascular and diffuse lymphocytic inflammation are not specific for failed metal-on-metal hip implants.

Authors:  Takaaki Fujishiro; Dirk Jan F Moojen; Naomi Kobayashi; Wouter J A Dhert; Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2010-10-29       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.