Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT.

Jayasai R Rajagopal1, Faraz Farhadi1, Taylor Richards1, Moozhan Nikpanah1, Pooyan Sahbaee1, Sujata M Shanbhag1, W Patricia Bandettini1, Babak Saboury1, Ashkan A Malayeri1, William F Pritchard1, Elizabeth C Jones1, Ehsan Samei1, Marcus Y Chen1.   

Abstract

PURPOSE: To compare the performance of energy-integrating detector (EID) CT, photon-counting detector CT (PCCT), and high-resolution PCCT (HR-PCCT) for the visualization of coronary plaques and reduction of stent artifacts in a phantom model.
MATERIALS AND METHODS: An investigational scanner with EID and PCCT subsystems was used to image a coronary artery phantom containing cylindrical probes simulating different plaque compositions. The phantom was imaged with and without coronary stents using both subsystems. Images were reconstructed with a clinical cardiac kernel and an additional HR-PCCT kernel. Regions of interest were drawn around probes and evaluated for in-plane diameter and a qualitative comparison by expert readers. A linear mixed-effects model was used to compare the diameter results, and a Shrout-Fleiss intraclass correlation coefficient was used to assess consistency in the reader study.
RESULTS: Comparing in-plane diameter to the physical dimension for nonstented and stented phantoms, measurements of the HR-PCCT images were more accurate (nonstented: 4.4% ± 1.1 [standard deviation], stented: -9.4% ± 4.6) than EID (nonstented: 15.5% ± 4.0, stented: -19.5% ± 5.8) and PCCT (nonstented: 19.4% ± 2.5, stented: -18.3% ± 4.4). Our analysis of variance found diameter measurements to be different across image groups for both nonstented and stented cases (P < .001). HR-PCCT showed less change on average in percent stenosis due to the addition of a stent (-5.5%) than either EID (+90.5%) or PCCT (+313%). For both nonstented and stented phantoms, observers rated the HR-PCCT images as having higher plaque conspicuity and as being the image type that was least impacted by stent artifacts, with a high level of agreement (interclass correlation coefficient = 0.85).
CONCLUSION: Despite increased noise, HR-PCCT images were able to better visualize coronary plaques and reduce stent artifacts compared with EID or PCCT reconstructions.Keywords: CT-Spectral Imaging (Dual Energy), Phantom Studies, Cardiac, Physics, Technology Assessment© RSNA, 2021. 2021 by the Radiological Society of North America, Inc.

Entities:  

Keywords:  CT-Spectral Imaging (Dual Energy); Cardiac; Phantom Studies; Physics; Technology Assessment

Year:  2021        PMID: 34778782      PMCID: PMC8581588          DOI: 10.1148/ryct.2021210102

Source DB:  PubMed          Journal:  Radiol Cardiothorac Imaging        ISSN: 2638-6135


  18 in total

Review 1.  Simultaneous inference in general parametric models.

Authors:  Torsten Hothorn; Frank Bretz; Peter Westfall
Journal:  Biom J       Date:  2008-06       Impact factor: 2.207

2.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

Authors:  Wei Zhou; David J Bartlett; Felix E Diehn; Katrina N Glazebrook; Amy L Kotsenas; Rickey E Carter; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2019-04       Impact factor: 6.016

3.  Quarter-millimeter spectral coronary stent imaging with photon-counting CT: Initial experience.

Authors:  Rolf Symons; Yves De Bruecker; John Roosen; Laurent Van Camp; Tyler E Cork; Steffen Kappler; Stefan Ulzheimer; Veit Sandfort; David A Bluemke; Amir Pourmorteza
Journal:  J Cardiovasc Comput Tomogr       Date:  2018-10-15

Review 4.  Image quality in coronary CT angiography: challenges and technical solutions.

Authors:  Olivier Ghekiere; Rodrigo Salgado; Nico Buls; Tim Leiner; Isabelle Mancini; Piet Vanhoenacker; Paul Dendale; Alain Nchimi
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

5.  Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels: Tapping the Potential of a New Technology for Stent Imaging.

Authors:  Jochen von Spiczak; Manoj Mannil; Benjamin Peters; Tilman Hickethier; Matthias Baer; André Henning; Bernhard Schmidt; Thomas Flohr; Robert Manka; David Maintz; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2018-08       Impact factor: 6.016

Review 6.  Photon-counting CT: Technical Principles and Clinical Prospects.

Authors:  Martin J Willemink; Mats Persson; Amir Pourmorteza; Norbert J Pelc; Dominik Fleischmann
Journal:  Radiology       Date:  2018-09-04       Impact factor: 11.105

7.  Photon-Counting CT: High-Resolution Imaging of Coronary Stents.

Authors:  Manoj Mannil; Tilman Hickethier; Jochen von Spiczak; Matthias Baer; André Henning; Madeleine Hertel; Bernhard Schmidt; Thomas Flohr; David Maintz; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2018-03       Impact factor: 6.016

8.  How Low Can We Go in Radiation Dose for the Data-Completion Scan on a Research Whole-Body Photon-Counting Computed Tomography System.

Authors:  Zhicong Yu; Shuai Leng; Zhoubo Li; Ahmed F Halaweish; Steffen Kappler; Erik L Ritman; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2016 Jul-Aug       Impact factor: 1.826

9.  Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies.

Authors:  Ralf Gutjahr; Ahmed F Halaweish; Zhicong Yu; Shuai Leng; Lifeng Yu; Zhoubo Li; Steven M Jorgensen; Erik L Ritman; Steffen Kappler; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2016-07       Impact factor: 6.016

10.  Feasibility of improving vascular imaging in the presence of metallic stents using spectral photon counting CT and K-edge imaging.

Authors:  Monica Sigovan; Salim Si-Mohamed; Daniel Bar-Ness; Julia Mitchell; Jean-Baptiste Langlois; Philippe Coulon; Ewald Roessl; Ira Blevis; Michal Rokni; Gilles Rioufol; Philippe Douek; Loic Boussel
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379

View more
  2 in total

Review 1.  [Spectral computed tomography in the age of photon-counting X-ray detectors].

Authors:  Lukas T Rotkopf; Eckhard Wehrse; Matthias F Froelich
Journal:  Radiologie (Heidelb)       Date:  2022-05-20

Review 2.  An introduction to photon-counting detector CT (PCD CT) for radiologists.

Authors:  Yuko Nakamura; Toru Higaki; Shota Kondo; Ikuo Kawashita; Isao Takahashi; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2022-10-18       Impact factor: 2.701

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.