Literature DB >> 34728844

Silicone allergy associated with intraocular silicone ball prosthesis in a dog.

Yuichiro Muramatsu1, Usio Fukushima1, Soroku Kudo1, Takumi Akatsuka1, Kenichiro Ono1, Hidehiro Hirao1.   

Abstract

A 13-year-old, male Pomeranian dog was presented for scleral rupture with intraocular hemorrhage and retinal detachment in the right eye. After intrascleral silicone ball prosthesis, recurrent swelling and granulomatous blepharitis were observed for 140 d and finally melting keratitis developed. Although an intraorbital prosthesis was implanted, recurrent, serious, erosive, and ulcerative blepharitis developed with high plasma C-reactive protein concentrations. Since the blepharitis could not be controlled, the silicone ball was removed and the affected orbit was debrided. The blepharitis resolved rapidly, and the orbit healed routinely. Positive allergic reactions to silicone were discovered through a patch test. Key clinical message: To the authors' knowledge, this is the first report on silicone allergy in a dog with positive allergic reactions to silicone in the patch test. Copyright and/or publishing rights held by the Canadian Veterinary Medical Association.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 34728844      PMCID: PMC8543662     

Source DB:  PubMed          Journal:  Can Vet J        ISSN: 0008-5286            Impact factor:   1.008


  25 in total

1.  Allergic contact dermatitis of bovine teat skin caused by milking machine cluster rubber.

Authors:  M Holzhauer; O C Sampimon; J Sol; A van Walderveen; C J W van Ginkel
Journal:  Vet Rec       Date:  2004-02-14       Impact factor: 2.695

Review 2.  Contact dermatitis: a comparative and translational review of the literature.

Authors:  Karen K Ho; Karen L Campbell; Sidonie N Lavergne
Journal:  Vet Dermatol       Date:  2015-07-16       Impact factor: 1.589

Review 3.  Allergic contact dermatitis.

Authors:  Ian Kimber; David A Basketter; G Frank Gerberick; Rebecca J Dearman
Journal:  Int Immunopharmacol       Date:  2002-02       Impact factor: 4.932

Review 4.  Silicone allergy: A new cause for cochlear implant extrusion and its management.

Authors:  Larisa D Kunda; Katrina R Stidham; Michelle M Inserra; Peter S Roland; Daniel Franklin; Joseph B Roberson
Journal:  Otol Neurotol       Date:  2006-12       Impact factor: 2.311

5.  Allergic and nonallergic hypersensitivity reactions to silicone: a report of one case.

Authors:  A Rubio; C Ponvert; O Goulet; P Scheinmann; J de Blic
Journal:  Allergy       Date:  2009-07-17       Impact factor: 13.146

6.  [Type I hypersensitivity to a silicone tube after laryngectomy].

Authors:  B A Stuck; K Hecksteden; L Klimek; K Hörmann
Journal:  HNO       Date:  2004-03       Impact factor: 1.284

7.  A case of superficial suppurative necrolytic dermatitis of miniature schnauzers with identification of a causative agent using patch testing.

Authors:  Nobuo Murayama; Kuniaki Midorikawa; Masahiko Nagata
Journal:  Vet Dermatol       Date:  2008-11-14       Impact factor: 1.589

8.  Patch-test results of the North American Contact Dermatitis Group 2005-2006.

Authors:  Kathryn A Zug; Erin M Warshaw; Joseph F Fowler; Howard I Maibach; Donald L Belsito; Melanie D Pratt; Denis Sasseville; Frances J Storrs; James S Taylor; C G Toby Mathias; Vincent A Deleo; Robert L Rietschel; James Marks
Journal:  Dermatitis       Date:  2009 May-Jun       Impact factor: 4.845

9.  Contact hypersensitivity to stainless steel cages (chromium metal) in hairless descendants of mexican hairless dogs.

Authors:  Tohru Kimura
Journal:  Environ Toxicol       Date:  2007-04       Impact factor: 4.119

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.