Literature DB >> 34717230

Cerebral aneurysm flow diverter modeled as a thin inhomogeneous porous medium in hemodynamic simulations.

Armin Abdehkakha1, Adam L Hammond1, Tatsat R Patel1, Adnan H Siddiqui2, Gary F Dargush3, Hui Meng4.   

Abstract

Rapid and accurate simulation of cerebral aneurysm flow modifications by flow diverters (FDs) can help improving patient-specific intervention and predicting treatment outcome. However, when FD devices are explicitly represented in computational fluid dynamics (CFD) simulations, flow around the stent wires must be resolved, leading to high computational cost. Classic porous medium (PM) methods can reduce computational expense but cannot capture the inhomogeneous FD wire distribution once implanted on a cerebral artery and thus cannot accurately model the post-stenting aneurysmal flow. We report a novel approach that models the FD flow modification as a thin inhomogeneous porous medium (iPM). It improves over the classic PM approaches in two ways. First, the FD is more appropriately treated as a thin screen, which is more accurate than the classic 3D-PM-based Darcy-Forchheimer relation. Second, pressure drop is calculated cell-by-cell using the local FD geometric parameters across an inhomogeneous PM. We applied the iPM technique to simulating the post-stenting hemodynamics of three patient-specific aneurysms. To test its accuracy and speed, we compared the results from the iPM technique against CFD simulations with explicit FD devices. The iPM CFD ran 500% faster than the explicit CFD while achieving 94%-99% accuracy; thus, iPM is a promising clinical bedside modeling tool to assist endovascular interventions with FD and stents.
Copyright © 2021. Published by Elsevier Ltd.

Entities:  

Keywords:  CFD Simulation; Intracranial aneurysm; Porous media; Stent modeling; Stent simulation

Mesh:

Year:  2021        PMID: 34717230      PMCID: PMC9372908          DOI: 10.1016/j.compbiomed.2021.104988

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   6.698


  18 in total

1.  Strategy for modeling flow diverters in cerebral aneurysms as a porous medium.

Authors:  M Raschi; F Mut; R Löhner; J R Cebral
Journal:  Int J Numer Method Biomed Eng       Date:  2014-03-28       Impact factor: 2.747

2.  Intracranial stents being modeled as a porous medium: flow simulation in stented cerebral aneurysms.

Authors:  L Augsburger; P Reymond; D A Rufenacht; N Stergiopulos
Journal:  Ann Biomed Eng       Date:  2010-11-02       Impact factor: 3.934

3.  Numerical simulation of aneurysmal haemodynamics with calibrated porous-medium models of flow-diverting stents.

Authors:  Yujie Li; Mingzi Zhang; David I Verrelli; Winston Chong; Makoto Ohta; Yi Qian
Journal:  J Biomech       Date:  2018-08-29       Impact factor: 2.712

4.  Numerical study of hemodynamics in brain aneurysms treated with flow diverter stents using porous medium theory.

Authors:  Hooman Yadollahi-Farsani; Erik Scougal; Marcus Herrmann; Wei Wei; David Frakes; Brian Chong
Journal:  Comput Methods Biomech Biomed Engin       Date:  2019-05-02       Impact factor: 1.763

5.  Efficient simulation of a low-profile visualized intraluminal support device: a novel fast virtual stenting technique.

Authors:  Shengzhang Wang; Xinjian Yang; Qianqian Zhang; Jian Liu; Yisen Zhang; Ying Zhang; Zhongbin Tian; Wenqiang Li; Junfan Chen; Xiao Mo; Yunhan Cai; Nikhil Paliwal; Hui Meng; Yang Wang
Journal:  Chin Neurosurg J       Date:  2018-03-22

Review 6.  High WSS or low WSS? Complex interactions of hemodynamics with intracranial aneurysm initiation, growth, and rupture: toward a unifying hypothesis.

Authors:  H Meng; V M Tutino; J Xiang; A Siddiqui
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-18       Impact factor: 3.825

7.  Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up.

Authors:  Alessandra Biondi; Vallabh Janardhan; Jeffrey M Katz; Kimberly Salvaggio; Howard A Riina; Y Pierre Gobin
Journal:  Neurosurgery       Date:  2007-09       Impact factor: 4.654

8.  Comparison of two stents in modifying cerebral aneurysm hemodynamics.

Authors:  Minsuok Kim; Dale B Taulbee; Markus Tremmel; Hui Meng
Journal:  Ann Biomed Eng       Date:  2008-02-09       Impact factor: 3.934

9.  Fast Virtual Stenting with Active Contour Models in Intracranical Aneurysm.

Authors:  Jingru Zhong; Yunling Long; Huagang Yan; Qianqian Meng; Jing Zhao; Ying Zhang; Xinjian Yang; Haiyun Li
Journal:  Sci Rep       Date:  2016-02-15       Impact factor: 4.379

10.  Improving accuracy for finite element modeling of endovascular coiling of intracranial aneurysm.

Authors:  Robert J Damiano; Vincent M Tutino; Saeb R Lamooki; Nikhil Paliwal; Gary F Dargush; Jason M Davies; Adnan H Siddiqui; Hui Meng
Journal:  PLoS One       Date:  2019-12-27       Impact factor: 3.240

View more
  1 in total

1.  Realistic computer modelling of stent retriever thrombectomy: a hybrid finite-element analysis-smoothed particle hydrodynamics model.

Authors:  S Mostafa Mousavi J S; Danial Faghihi; Kelsey Sommer; Mohammad M S Bhurwani; Tatsat R Patel; Briana Santo; Muhammad Waqas; Ciprian Ionita; Elad I Levy; Adnan H Siddiqui; Vincent M Tutino
Journal:  J R Soc Interface       Date:  2021-12-15       Impact factor: 4.118

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.