Literature DB >> 34705630

A validation study of a ballistocardiograph sleep tracker against polysomnography.

Mahnoosh Kholghi1, Irene Szollosi2, Mitchell Hollamby2, DanaKai Bradford1, Qing Zhang1.   

Abstract

STUDY
OBJECTIVES: Consumer home sleep trackers provide a great opportunity for longitudinal objective sleep monitoring. Nonwearable sleep devices cause little to no disruption in the daily life routine and need little maintenance. However, their validity needs further investigation. This study aims to evaluate the accuracy of sleep outcomes of EMFIT Quantified Sleep (QS), an unobtrusive nonwearable sleep tracker based on ballistocardiography, against polysomnography.
METHODS: 62 sleep-lab patients underwent a single clinical polysomnography with measures simultaneously collected through polysomnography and EMFIT QS. Resting heart rate, total sleep time, wake after sleep onset, sleep onset latency, and duration in sleep stages, collected from the 2 devices, were compared using paired t-tests and their agreement analyzed using Bland-Altman plots. Additionally, continuous heart rate and sleep stages in 30-seconds epochs were evaluated.
RESULTS: EMFIT QS data loss occurred in 47% of participants. In the remaining 33 participants (15 women, with mean age of 53.7 ± 16.5 years), EMFIT QS overestimated total sleep time by 177.5 ± 119.4 minutes (p<0.001) and underestimated wake after sleep onset by 44.74 ± 68.81 minutes (P < .001). It accurately measured average resting heart rate and was able to distinguish sleep onset latency with some accuracy. However, the agreement between EMFIT QS and polysomnography on sleep-wake detection was low (kappa = 0.13, P < .001), EMFIT QS failed to distinguish sleep stages.
CONCLUSIONS: A consensus between polysomnography and EMFIT QS was found in sleep onset latency and average heart rate. There was significant discrepancy and lack of consensus in other sleep outcomes. These findings indicated that further development is necessary before using EMFIT QS in clinical and research settings. CLINICAL TRIAL REGISTRATION: Registry: Australian New Zealand Clinical Trials Registry; Name: Sleep parameter validation of a consumer home sleep monitoring device, EMFIT Quantified Sleep (QS), against Polysomnography; URL: https://www.anzctr.org.au/ACTRN12621000600842.aspx; Identifier: ACTRN12621000600842. CITATION: Kholghi M, Szollosi I, Hollamby M, Bradford D, Zhang Q. A validation study of a ballistocardiograph sleep tracker against polysomnography. J Clin Sleep Med. 2022;18(4):1203-1210.
© 2022 American Academy of Sleep Medicine.

Entities:  

Keywords:  EMFIT QS; polysomnography; sleep measurements; validation

Mesh:

Year:  2022        PMID: 34705630      PMCID: PMC8974370          DOI: 10.5664/jcsm.9754

Source DB:  PubMed          Journal:  J Clin Sleep Med        ISSN: 1550-9389            Impact factor:   4.062


  14 in total

1.  Fatigue, alcohol and performance impairment.

Authors:  D Dawson; K Reid
Journal:  Nature       Date:  1997-07-17       Impact factor: 49.962

2.  Sleep Parameter Assessment Accuracy of a Consumer Home Sleep Monitoring Ballistocardiograph Beddit Sleep Tracker: A Validation Study.

Authors:  Jarno Tuominen; Karoliina Peltola; Tarja Saaresranta; Katja Valli
Journal:  J Clin Sleep Med       Date:  2019-03-15       Impact factor: 4.062

Review 3.  A systematic review of the accuracy of sleep wearable devices for estimating sleep onset.

Authors:  Hannah Scott; Leon Lack; Nicole Lovato
Journal:  Sleep Med Rev       Date:  2019-11-06       Impact factor: 11.609

4.  Relationship of arousals from sleep to sympathetic nervous system activity and BP in obstructive sleep apnea.

Authors:  J S Loredo; M G Ziegler; S Ancoli-Israel; J L Clausen; J E Dimsdale
Journal:  Chest       Date:  1999-09       Impact factor: 9.410

5.  Insomnia with objective short sleep duration and risk of incident cardiovascular disease and all-cause mortality: Sleep Heart Health Study.

Authors:  Suzanne M Bertisch; Benjamin D Pollock; Murray A Mittleman; Daniel J Buysse; Lydia A Bazzano; Daniel J Gottlieb; Susan Redline
Journal:  Sleep       Date:  2018-06-01       Impact factor: 5.849

6.  Measures of sleep and cardiac functioning during sleep using a multi-sensory commercially-available wristband in adolescents.

Authors:  Massimiliano de Zambotti; Fiona C Baker; Adrian R Willoughby; Job G Godino; David Wing; Kevin Patrick; Ian M Colrain
Journal:  Physiol Behav       Date:  2016-03-09

7.  Validity of a commercial wearable sleep tracker in adult insomnia disorder patients and good sleepers.

Authors:  Seung-Gul Kang; Jae Myeong Kang; Kwang-Pil Ko; Seon-Cheol Park; Sara Mariani; Jia Weng
Journal:  J Psychosom Res       Date:  2017-03-23       Impact factor: 3.006

Review 8.  Wearable Sleep Technology in Clinical and Research Settings.

Authors:  Massimiliano de Zambotti; Nicola Cellini; Aimée Goldstone; Ian M Colrain; Fiona C Baker
Journal:  Med Sci Sports Exerc       Date:  2019-07       Impact factor: 5.411

9.  Evaluations of Commercial Sleep Technologies for Objective Monitoring During Routine Sleeping Conditions.

Authors:  Jason D Stone; Lauren E Rentz; Jillian Forsey; Jad Ramadan; Rachel R Markwald; Victor S Finomore; Scott M Galster; Ali Rezai; Joshua A Hagen
Journal:  Nat Sci Sleep       Date:  2020-10-27

10.  Recent developments in home sleep-monitoring devices.

Authors:  Jessica M Kelly; Robert E Strecker; Matt T Bianchi
Journal:  ISRN Neurol       Date:  2012-10-14
View more