Literature DB >> 34703310

A Narrative Review of Ultrasound Technologies for the Prediction of Neoadjuvant Chemotherapy Response in Breast Cancer.

Jing Wang1, Yanhua Chu1, Baohua Wang1, Tianan Jiang1.   

Abstract

The incidence and mortality rate of breast cancer (BC) in women currently ranks first worldwide, and neoadjuvant chemotherapy (NAC) is widely used in patients with BC. A variety of imaging assessment methods have been used to predict and evaluate the response to NAC. Ultrasound (US) has many advantages, such as being inexpensive and offering a convenient modality for follow-up detection without radiation emission. Although conventional grayscale US is typically used to predict the response to NAC, this approach is limited in its ability to distinguish viable tumor tissue from fibrotic scar tissue. Contrast-enhanced ultrasound (CEUS) combined with a time-intensity curve (TIC) not only provides information on blood perfusion but also reveals a variety of quantitative parameters; elastography has the potential capacity to predict NAC efficiency by evaluating tissue stiffness. Both CEUS and elastography can greatly improve the accuracy of predicting NAC responses. Other US techniques, including three-dimensional (3D) techniques, quantitative ultrasound (QUS) and US-guided near-infrared (NIR) diffuse optical tomography (DOT) systems, also have advantages in assessing NAC response. This paper reviews the different US technologies used for predicting NAC response in BC patients based on the previous literature.
© 2021 Wang et al.

Entities:  

Keywords:  breast cancer; neoadjuvant chemotherapy; ultrasound

Year:  2021        PMID: 34703310      PMCID: PMC8523361          DOI: 10.2147/CMAR.S331665

Source DB:  PubMed          Journal:  Cancer Manag Res        ISSN: 1179-1322            Impact factor:   3.989


Introduction

The incidence and mortality rate of breast cancer (BC) in women currently ranks first worldwide,1 and based on current NCCN guidelines, patients with different molecular types of BC should undergo neoadjuvant chemotherapy (NAC) regardless of their primary stage or aim of surgery.2 NAC not only reduces tumor grade and improves patients’ opportunities for surgery, but also allows new advances in cancer management by identifying new genetic pathways and drugs involved in cancer and improving patient survival.3–7 However, some patients receiving NAC may gradually develop resistance to drugs during the process of chemotherapy, which limits its clinical efficacy and leads to treatment failure. These patients would benefit from planning treatment and surgery methods by assessing the response to NAC considering new treatment methods.8 Chemotherapy can produce physiological and psychological side effects of varying degrees. Non-responders need to be accurately and promptly identified to avoid ineffective chemotherapy and side effects.9,10 As a result, accurately monitoring and evaluating the efficacy of NAC is becoming increasingly crucial. At present, the gold standard for evaluating the response to NAC is pathological assessment,11 and the relevant methods include the residual cancer burden score (RCB)12 and Miller-Payne system.13 As pathological assessment requires breast tumor specimens after surgery, it is not suitable for dynamically monitoring the efficacy of NAC. In fact, imaging assessments are used primarily to monitor and evaluate the response to NAC. In addition, accurate imaging assessment of the residual tumor after NAC can provide important information for selecting the most appropriate surgical procedure and for predicting patient prognosis. A variety of imaging assessment methods, including magnetic resonance imaging (MRI), computed tomography (CT), positron emission tomography (PET), ultrasound (US), mammography (MM) and so on, have been used to predict and evaluate the response to NAC. Each imaging assessment method has unique advantages and disadvantages according to the different imaging principles, expenditure and safety. Many studies maintain that MRI and PET exhibit higher accuracy in predicting the efficacy of NAC.14–18 Changes in tumor size are typically used to monitor the efficacy of NAC by palpation and imaging methods. According to Response Evaluation Criteria in Solid Tumors (RECIST) criteria, US is not suitable for monitoring tumor size due to high operator dependence and low reproducibility.19 However, with the development of new techniques, such as contrast-enhanced imaging, elastography, and 3D imaging, US is increasingly applied to predicting the efficacy of NAC. The objective of this paper is to review the role of US in monitoring the response to NAC in BC patients. According to a PubMed search, using the search terms “breast cancer”, “neoadjuvant chemotherapy” and “ultrasound” and screening the search results, this paper reviews the previous literature and summarizes these studies.

Grayscale US for Assessing Response to NAC

US imaging is based on the conduction and reflection of high-frequency mechanical sound waves in the tissue, and the information of ultrasonic impulses and their reflections as echoes are converted and processed into real-time images.20 Grayscale US has been widely used to distinguish malignant from benign breast tumors, and it has also been applied to predict the response to NAC. Grayscale US is primarily applied to measure changes in tumor size after NAC. Most researchers have demonstrated that US underestimates breast tumor size.21–24 However, it was reported that US overestimates BC tumor size. Vriens et al examined 182 patients with BC and found that US overestimated size in 20% of patients.25 Whether US has an advantage in estimating tumor size compared with other imaging methods has not been determined. Stein et al measured 6543 primary BC patients and found that the correlation with histology was 0.61 for MM and 0.60 for US.26 They demonstrated that the prediction of tumor size by US and MM was coincident. The result was the same as that of Chagpar et al study.27 However, Keune et al reported that US correctly measures residual tumor size in response to NAC more often than MM (91.3% vs 51.9%).28 Both Vriens et al25 and Choi et al29 study compared the role of MRI and US in measuring tumor size and found that both were consistent in estimating size. The sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), false-negative rates (FNR) and false-positive rates (FPR) were 36–61%, 78–90%, 71–74%, 60–67%, 29–75%, 20–38%, 35–60%, respectively, for US-predicted remission in BC after NAC.30–35 The reason for the lower prediction efficiency might be due to the potential limitation of the ability of US to distinguish viable tumor tissue from fibrotic scar tissue.30–32

Contrast-Enhanced Ultrasound (CEUS) for Assessing Response to NAC

There is currently increasing awareness that anatomical approaches based on measuring tumor size have substantial limitations and that morphological changes often manifest later than functional changes.36 As a result, CEUS, dynamic contrast-enhanced MRI (DCE-MRI) and fluorodeoxyglucose positron emission tomography and computed tomography (FDG-PET/CT), which can quantify tumor functions, are playing increasingly larger roles in evaluating and predicting the response to NAC. CEUS might be one of the most direct imaging tools for visualizing perfusion changes in tumors.37 In fact, the development of contrast agents has improved the diagnostic accuracy of US over the past decade.38 Sonovue, a second-generation US contrast agent, has a microbubble diameter of 2 to 4 mm. It can remain within the blood pool because it is close to the diameter of blood cells and cannot diffuse into the interstitial space. CEUS has been widely used in the ultrasonic diagnosis of diseases of various organs throughout the body. In recent years, CEUS has also been used to evaluate the efficacy of NAC, and it was demonstrated to be effective for assessing the response to NAC in BC patients compared to other methods.25,39 Previous studies showed that the sensitivity, specificity, accuracy, PPV, NPV, area under the curve (AUC), positive and negative likelihood ratios (LR+ and LR-) and diagnostic odds ratios (ORs) of CEUS imaging for predicting response to NAC were 85–96%, 78–87%, 84–86%, 92%, 78%, 0.71–0.92, 4.49–5.5, 0.15–0.16 and 32.21–36, respectively.16,40–44 Currently, CEUS is recommended for the evaluation of the efficacy of NAC and may be a promising tool for the evaluation of NAC response.45 Imaging may underestimate or overestimate the size of breast tumors, as mentioned above. It was found that the tumor sizes measured both before and after NAC by CEUS were larger than those measured by conventional grayscale US.40 Although CEUS has no significant advantage in the accuracy of tumor size measurement before NAC, it has a higher correlation with pathological results after NAC, and the measurement accuracy is higher than that of other imaging methods.45 In addition, necrosis at the tumor center was found to be detected early by CEUS, which showed a local blood perfusion defect, whereas conventional grayscale US was unable to detect whether there was necrosis unless there was a fluid area.40 The TIC of CEUS reflects the speed and quantity of the contrast agent in the tumor microvasculature. TIC analysis is a state-of-the-art technique for CEUS video quantification that contains a variety of blood perfusion quantitative parameters.40,46,47 The quantitative parameters of blood perfusion are slightly different according to different TIC analysis software. Generally, blood perfusion quantitative parameters mainly include PI (peak intensity, the maximum intensity of the time-intensity curve during bolus transit), TTP (time to peak, time needed to reach peak intensity), RT (rise time, the difference between TTP and the time the first microbubble reached the lesion), MTT (mean transit time, circulation time of contrast agent in the area under investigation), WIS (wash-in slope, the ratio of PI to TTP), AS (ascending slope, the slope of the ascending branch of TIC, which showed mean perfusion speed after presence of the contrast agent and reflected local tissue perfusion rate), AUC and so on. TIC analyses of BC usually show shortening of RT and TTP and increasing PI and AS. Chemotherapy causes cytotoxic tumor cell death, resulting in reduced tissue vascular endothelial growth factor levels, apoptosis of immature endothelial cells with secondary vascular shutdown, and decreased blood perfusion, which in turn leads to slower wash-in of contrast agents.48 However, a poor response to NAC results in ongoing production of angiogenic factors that might maintain or increase the proportion of immature vessels.49,50 According to the changes in blood vessels in the tumor after NAC PCR, PI,16,40,49 WIS,40 AS 16 and AUC51 were found to be significantly decreased, and TTP,40,43,49 MTT49 and RT44 were significantly increased. Although multiple logistic regression analysis revealed that changes in quantitative parameters of TIC and diameter of the tumor were significant independent predictors of pCR, the parameters of TIC, which are used as a functional technique to evaluate tumor response to NAC, were superior and predicted earlier in response to NAC than changes in tumor size.49 In fact, placement of the regions of interest (ROIs) in CEUS research is also crucial for quantitative TIC analysis.52,53 TIC parameters were analyzed for different ROIs in Lee et al research.54 ROI 1, ROI 2, ROI 3, and ROI 4 targeted the hotspot area of greatest enhancement, area of hyperenhancement, entire tumor on grayscale ultrasound and normal parenchyma, respectively, and the results led to a recommendation for the less subjective ROI 2 or ROI 3. Studies have confirmed that breast CEUS combined with TIC curve analysis not only provides information about blood perfusion but also provides a variety of quantitative parameters that greatly improve the accuracy of predicting the response to NAC.

Elastography for Assessing the Response to NAC

Elastography, which is similar to palpation but more sensitive and objective, can assess tissue stiffness. Elastography is a recently developed, convenient and noninvasive imaging technique. There are two types of techniques in elastography: strain elastography and shear wave elastography. The strain elastography technique includes strain elastography (SE) and acoustic radiation force impulse (ARFI), while the shear wave elastography technique includes transient elastography (TE), point shear wave elastography (pSWE) and shear wave elastography (SWE). The most common methods that are widely used in the clinic are SE and SWE. In general, the ability of elastography to predict the efficacy of NAC was significantly higher than that of grayscale ultrasound and comparable to that of CEUS and MRI.42,55,56 The sensitivity, specificity, accuracy, PPV, NPV and AUC of predicting the efficacy of NAC by elastography were found to be 59–100%, 63–100%, 74–83%, 71–79%, 66–86% and 0.75–0.88, respectively, in previous studies.42,56–59 SE is an imaging modality based on mechanical properties that uses manual compression and measures the degree of tissue deformation.60 The Tsukuba elasticity score (TES) can be used for scoring according to different colors, which represent the different stiffnesses of the tissue.61 In addition to the elastography score, the strain rate (SR) can be calculated by software that measures the strain rate ratio of elastography according to the ratio of stiffness between the lesion area and the surrounding normal tissue.62,63 Stiffer masses are more likely to represent malignancies.64 Hayashi et al first reported tumor stiffness assessed using SE.65 They examined the correlation between elasticity scores and treatment responses. The results demonstrated that stiffer tumors were less likely to exhibit clinical responses and pCR than more compliant tumors. However, other research demonstrated that SE imaging before NAC had no relationship with pathological complete response.64 The change in score and SR of elastography after NAC can be acquired by evaluating the score and SR of elastography before and after NAC. The score and SR of elastography of the tumors obtaining pCR were found to be decreased, and the degree of reduction was higher than those without pCR.57,58 SE can predict the efficacy of NAC earlier. Falou et al found that SE can predict the response of tumors to NAC in the medium term (4 weeks) by using SR, and the sensitivity and specificity were 100%.57 Fernandes et al demonstrated that SR can predict the pCR of tumors in the early stage (2 weeks)58 with a sensitivity and specificity of 84% and 85%, respectively. Wang et al analyzed the parameters of CUES and SE before and after NAC for BC, and the results showed that the AUCs of CEUS and SE in predicting the efficacy of NAC were 0.86 and 0.72, respectively, and the predictive accuracies were 89% and 91%, respectively.42 They indicated that CEUS and SE had equal advantages in predicting the response to NAC, which was the same conclusion as that of the Gu et al study.64 However, SE also has certain limitations. First, SE is highly dependent on the operators due to manual pressurization. As a result, human error can occur due to the difference in the measurement by different operators. Second, the elastography score is based on the visual observation of the color of the ROI, which is highly subjective and may also introduce human error. SWE, which uses acoustic radiation force to introduce a disturbance and measures the speed of propagation of shear waves, can be used in conjunction with Hooke’s law to derive the Young’s modulus of tissue.60,66,67 The parameter maximum stiffness (Emax), mean stiffness (Emean), and standard deviation (SD), where E is defined by Young’s modulus and measured in kilopascals and SD gives an indication of heterogeneity, refer to the elasticity values of the tissue within an ROI outlined on the US image. High mean stiffness values are more likely to be malignant.66–70 SWE can play a complementary role to conventional US.66,67 Stiffer tumors were found to be less likely to exhibit clinical responses and pCR.71 Young’s modulus of tumors with pCR after NAC was lower than that of tumors without pCR.59 The change in Young’s modulus before and after NAC could be calculated, and the larger the change was, the more likely was the indication of a response to NAC.56,59,72 SWE is also believed to be an effective early predictor of pCR after NAC. Evans et al demonstrated that the changes in tumor stiffness after 3 weeks of NAC were closely related to pCR.56 Jing et al showed that the response to NAC could be predicted by the change in Young’s modulus two weeks after NAC, and the predictive sensitivity and specificity were 73% and 86%, respectively.72 One advantage of SWE is that residual fibrous masses with no residual cancer tend to appear compliant in SWE, so that assessment by SWE is less prone to errors. However, there are a few limitations of SWE. It is difficult to assess deep lesions in BC patents, and the technique is influenced by patients’ breathing.56

Three-Dimensional (3D) Techniques for Assessing Response to NAC

A 3D automated breast volume scanner (ABVS) is another novel and innovative imaging technique in breast ultrasound. ABVS is not only an observer-independent, automated and standardized method but also provides a large field of view using high-frequency transducers, and computer-aided detection software significantly reduces interpretation time.73 ABVS has the ability to calculate volume using 3D imaging software, and multiple studies have shown a higher correlation with histopathological tumor response than conventional US.73 van Egdom et al compared the efficacy of ABVS and MRI in predicting the efficacy of NAC.74 In the study, MRI and ABVS showed absolute concordance in 73% of patients for mid-NAC evaluation. Tumor response to NAC in midtreatment was evaluated using the product change in the two largest perpendicular diameters (PC) or the longest diameter change (LDC) in the study by Wang et al.75 All four prediction methods (PC on axial planes, LDC on axial planes, PC on coronal planes and LDC on coronal planes) displayed high AUCs (0.83–0.89), and the sensitivity, specificity, PPV, and NPV were 86–88%, 62–85%, 28–51%, 96–98%, respectively. ABVS was used to predict final pCR after 4 cycles of chemotherapy. The results demonstrated that the ABVS is a useful tool for the evaluation of pCR after NAC. There are also additional 3D technologies applied in US, such as 3D power color US and 3D CEUS. Folkman et al emphasized the importance of angiogenesis in tumor growth.76 Vascular endothelial growth factors (VEGFs) are important regulatory cytokines, and microvessel density (MVD) has been the gold standard for assessing tumor angiogenesis. 3D power color flow with high-definition flow (HDF) technology facilitates the detection of vascular morphology imaging and better discriminates malignant breast tumors from benign lesions than 2D Doppler US. 3D power Doppler US provides high-resolution Doppler signal reflection and is not limited by the angle of the vessel, allowing 3D imaging of relevant vessels and observation of a tumor vascular mass by comparing perfusion changes and vessel density before and after NAC.77–79 3D power Doppler US with HDF was considered to accurately predict response according to determination of changes in vascularity after NAC. The vascularization index (VI, the ratio between the color boxes and the total number of voxels in the volume of interest, representing the vessel density in the defined volume), flow index (FI, the mean energy of the voxel per color, representing the average intensity of flow), and vascularization-flow index (VFI, mean color value for all voxels in the volume, representing the intensity of both vascularization and flow) were extracted for estimation of vascularization and flow index. It was demonstrated that the most accurate prediction of pCR was achieved after the second chemotherapy treatment, with an accuracy of 88% and an AUC of 0.76.80 The combined advantages of CEUS and 3D-US, 3D-CEUS, can evaluate tumor vascularity in a three-dimensional field. In Jia’s research, the 3D-CEUS score and DCE-MRI score were calculated according to the distribution and shape of breast tumor blood vessels in 3D-CEUS, and the enhancement pattern and index of tumor blood vessels in DCE-MRI, MVD and VEGF were also calculated.81 The results showed that the 3D-CEUS score, DCE-MRI score, MVD and VEGF were significantly decreased after NAC. It was also shown that the efficacy of 3D-CEUS and DCE-MRI in predicting pCR after NAC was consistent. The sensitivity, specificity, PPV, NPV, and AUC were 88% and 88%, 100% and 100%, 100% and 100%, 98% and 98% and 0.93 and 0.99, respectively, when the 3D-CEUS score was <1 and Δ3D-CEUS score was >6 after NAC. The study also demonstrated that the 3D-CEUS score was significantly correlated with MVD and VEGF both before and after NAC, while DCE-MRI was not correlated with MVD or VEGF. These results showed that 3D-CEUS is effective for assessing the response to NAC. Although 3D power color US and 3D-CEUS are rarely used in the clinic, they have a high accuracy in predicting the efficacy of NAC and are related to angiogenic factors, and 3D techniques still have certain development prospects.

Other US Techniques for Assessing Response to NAC

Changes in tumor echogenicity have also been applied to predict the response to NAC. Matsuda et al retrospectively examined 52 patients with triple-negative BC who received NAC and calculated changes in echogenicity.82 Pixel values are represented in black to white as different numeric values. It was demonstrated that the echogenicity changes (ratio and difference) in tumor and fat regions before and after NAC would predict pCR. The sensitivity, specificity and AUC were 70–74%, 81–82% and 0.78–0.80, respectively. Dobruch-Sobczak et al found that the changes in the echogenicity of tumors after 3 courses of NAC exhibited the strongest statistical correlation with the percentage of residual malignant cells used in histopathology to assess the response to treatment (odds ratio=60).83 Changes in tumor echogenicity were demonstrated to predict response with satisfactory accuracy and may be considered for early NAC monitoring. Assessing changes in echogenicity is based on the backscattered spectrum of QUS.84 NAC can induce microstructural transformation, cell death, heterogeneous tumor morphology and edema. These cellular organizational changes alter US backscatter and increase tumor echogenicity.85 Conventional US imaging involves “B-mode” images and loses much of the frequency-dependent information with the conversion of radiofrequency (RF) data. Compared to conventional US, QUS imaging retains these RF data and displays the data as a frequency spectrum using a fast Fourier transform (FFT) algorithm.86 As a result, QUS was found to predict the response to NAC more accurately by supplying more information from US images. QUS uses variation in the acoustic property within tissues to characterize microstructural features and has been used in the detection of tumor response to chemotherapy of cancer.87 QUS parameters include MBF (midband fit), SS (spectral slope), SI (spectral intercept), ACE (attenuation coefficient estimate), SAS (spacing among scatterers), ASD (acoustic-scatterer diameter) and AAC (average acoustic-scatterer concentration). Sannachi et al analyzed QUS parameters and texture features extracted from QUS parameters.87 The accuracies ranged from 68% to 92% according to different multifeature response classification algorithms (a linear discriminant analysis (LDA), a k-nearest-neighbor classifier (KNN), and a radial-basis-function support vector machine classifier (SVM-RBF)) to differentiate treatment responders. Tadayyon et al analyzed the capacity for predicting the response to NAC with QUS and an artificial neural network (ANN) classifier.88 They found that the sensitivity, specificity, accuracy, and AUC of the QUS model with an ANN classifier for predicting response were 89%, 85%, 87%, and 0.90, respectively. Changes in QUS parameters, particularly ultrasound backscatter intensity-based parameters, could distinguish responders and nonresponders at a later stage (week 8), while texture features could distinguish responders and nonresponders at early stages (weeks 1 and 4). The authors demonstrated an early-stage treatment response prediction model developed by combining QUS with texture analysis.87 Another study by Piotrzkowska-Wróblewska et al demonstrated that an integrated backscatter marker of QUS can better characterize the tumor pathological response and at an earlier stage (after the second and third NAC courses) of therapy with AUCs of 0.69 and 0.82, respectively.89 Recently, it was reported that the NIR technique utilizes intrinsic hemoglobin contrast, which is directly related to tumor angiogenesis and has shown great potential for evaluating tumor vasculature and oxygen consumption responses to NAC by optical tomography and optical spectroscopy.90 DOT is an optical imaging technique that uses near-infrared light to probe the absorption and scattering properties of biological tissues and to acquire information on tumor physiology, biochemistry, angiogenesis, and hypoxia.91–95 DOT combined with US has been explored for breast cancer diagnosis and monitoring NAC responses in BC. Combining pretreatment hemoglobin content and hemoglobin changes measured at early treatment cycles with standard pathological variables improves the predictive accuracy of NAC.96 The size and total hemoglobin concentration (THC) of the lesions were measured 1 day before biopsy and 1 to 2 days before surgery to predict BC response to NAC using US-guided DOT in the research of Zhi et al.91 The sensitivity, specificity, accuracy, PPV, NPV, and AUC were 74% and 80%, 77% and 53%, 77% and 38%, 93% and 88%, 74% and 77%, 0.75 and 0.69, respectively, when ΔTHC was 23.9% and ΔSIZE was 42.6%. Moreover, ΔTHC and ΔSIZE can be used for response evaluation and earlier prediction of the response after three rounds of NAC. The authors considered US-guided DOT to be useful for early evaluation and prediction of the response to NAC. The sensitivity, specificity, accuracy, PPV, and NPV of different US assessment methods for the prediction of neoadjuvant chemotherapy response in BC according to the results of the literature review are shown in Table 1. In addition, Figures 1 and 2 show US manifestations of different assessment methods in BC after NAC.
Table 1

Accuracy, Sensitivity, Specificity, Accuracy, PPV, and NPV of Different Assessment Methods for the Prediction of Neoadjuvant Chemotherapy Response in Breast Cancer

Sen(%)Spe(%)Accuracy(%)PPV(%)NPV(%)
Grayscale US36–6178–9071–7460–6729–75
CEUS85–9678–8784–869278
Elastography59–10063–10074–8371–7966–86
ABVS86–8862–8528–5196–98
3D power Doppler US(HDF)88
3D-CEUS8810010098
QUS(ANN)898587
DOT7477779374

Abbreviations: Sen, sensitivity; Spe, specificity; PPV, positive predictive value; NPV, negative predictive value; CEUS, contrast-enhanced ultrasound; ABVS, automated breast volume scanner; HDF, high-definition flow; QUS, quantitative ultrasound; ANN, artificial neural network; DOT, diffuse optical tomography.

Figure 1

① Representative ultrasound B-mode images and elastography images for a nonresponder and a responder acquired before and after treatment. (A) Nonresponders typically exhibited no change in tumor elasticity during treatment for several weeks (average strain ratios ranged from 1.29±0.04 before treatment to 1.23±0.11 at week 8). (B) Responders exhibited visibly detectable changes in tumor stiffness (average strain ratios ranged from 1.26±0.11 before treatment to 1.04±0.05 at week 8). Reprinted from Translational Oncology, Vol 6/edition number 1, Falou O, Sadeghi-Naini A, Prematilake S, et al, Evaluation of neoadjuvant chemotherapy response in women with locally advanced breast cancer using ultrasound elastography, Pages No.17–24, Copyright (2013), with permission from Elsevier. 57 ② SWE and corresponding pathologic images from a complete response patient after NAC. (A) The mean tumor stiffness value as determined at baseline was 223.1 kPa. (B) After the second cycle of chemotherapy, the mean tumor stiffness value was 44.7 kPa, and Δ-stiffness was 77.9%. (C and D) Pathological results before chemotherapy and after surgery. Reproduced with permission from Jing H, Cheng W, Li ZY, et al, Early evaluation of relative changes in tumor stiffness by shear wave elastography predicts the response to neoadjuvant chemotherapy in patients with breast cancer and John Wiley & Sons, Inc. © 2016 by the American Institute of Ultrasound in Medicine.72 ③ CEUS and TIC images from a complete response patient after NAC. Before NAC, (A) grayscale US showed a hypoechoic lesion with an irregularly shaped and distinct margin. (A) A CEUS image obtained 39 s after contrast agent injection showed an inhomogeneous hyperenhancement lesion with an indistinct margin. (B) The TIC on CEUS shows strong and rapid perfusion. After NAC, (C) US showed a decrease in the tumor size. (C) CEUS showed hypo-enhancement. (D) The TIC at CEUS shows weak and slow enhancement. Reprinted from European Journal of Radiology, Vol 103, Wan CF, Liu XS, Wang L, Zhang J, Lu JS, Li FH, Quantitative contrast-enhanced ultrasound evaluation of pathological complete response in patients with locally advanced breast cancer receiving neoadjuvant chemotherapy, Pages No. 118–123, Copyright (2018), with permission from Elsevier 49 ④ Example of the ABVS used for response evaluation. Frontal view (anterior-posterior) of the right breast. The left picture shows the tumor (upper left corner) pre-NAC. The right picture shows the same patients mid-NAC with a smaller tumor (upper left corner). Adapted from European Journal of Radiology, Vol 104, van Egdom LSE, Lagendijk M, Heijkoop EHM, et al, Threedimensional ultrasonography of the breast; An adequate replacement for MRI in neoadjuvant chemotherapy tumour response evaluation? - RESPONDER trial, Pages No. 94–100, Copyright (2018), with permission from Elsevier.74

Figure 2

⑤ Tumor margin obtained on 3D-HDF US images and an established 3D contour. (A) The tumor margin was sketched on a 2D slice B-mode US image, and the 3D contours were then established. The sketched margin is indicated with a blue dotted line. (B) Full image of 3D contours and vascular flow direction of the tumor. Reproduced from Shia WC, Huang YL, Wu HK, Chen DR, Using flow characteristics in three-dimensional power Doppler ultrasound imaging to predict complete responses in patients undergoing neoadjuvant chemotherapy and John Wiley and Sons. © 2017 by the American Institute of Ultrasound in Medicine.80 ⑥ Image of a responder case obtained by using ultrasound-guided diffuse optical tomography. (A and B) US images show US measuring a presize of 3.6 cm and a postsize of 0.7 cm in diameter. (C and D) Pre- and posttreatment reconstructed optical absorption maps show that the lesion was resolved in slices from 1 (top left, left to right) to 7 (bottom left, left to right) and from 2 to 4 (top row, left to right). The pre- and posttreatment THCs were 279.0 μmol/L and 128.0 μmol/L, respectively. The vertical color scale from blue to red is the THC in micromoles per liter from low to high. Reprinted from Translational Oncology, Vol 11/edition number 1, Zhi W, Liu G, Chang C, et al, Predicting treatment response of breast cancer to neoadjuvant chemotherapy using ultrasound-guided diffuse optical tomography, Pages No.56–64, Copyright (2018), with permission from Elsevier.91 ⑦ Changes in peripheral vessels before and after completion of NAC in breast cancer patients displayed by 3D-CEUS. (A) Before NAC, the 3D-CEUS image showed coarse peripheral vessels with radial distribution (arrow) at the strongest stage of perfusion. (B) After completion of NAC, radial peripheral vessels (arrow) disappeared at the strongest stage of perfusion. Reproduced from Jia WR, Tang L,Wang DB, et al. Three-dimensional contrast-enhanced ultrasound in response assessment for breast cancer: a comparison with dynamic contrast-enhanced magnetic resonance imaging and pathology. Sci Rep. 2016;6:33832.81 ⑧ Changes in rim perfusion displayed by 3D-CEUS before and after completion of NAC for another breast cancer patient. (A) Before NAC, 3D-CEUS image showed coarse rim perfusion (arrow) at the strongest stage of perfusion. (B) After completion of NAC, rim perfusion (arrow) disappeared at the strongest stage of perfusion. Reproduced from Jia WR, Tang L,Wang DB, et al. Three-dimensional contrast-enhanced ultrasound in response assessment for breast cancer: a comparison with dynamic contrast-enhanced magnetic resonance imaging and pathology. Sci Rep. 2016;6:33832.81 ⑨ QUS images from a representative non-responder (NR2) patient and a representative responder patient with outlines of core and margin ROIs. (A) B-mode images, (B) SS image, (C) SI images, (D) MBF images, (E) SAS images, (F) ASD, and (G) AAC images obtained prior to chemotherapy treatment initiation. Reproduced from Tadayyon H, Gangeh M, Sannachi L, et al. A priori prediction of breast tumour response to chemotherapy using quantitative ultrasound imaging and artificial neural networks. Oncotarget. 2019;10 (39):3910–3923.88

Accuracy, Sensitivity, Specificity, Accuracy, PPV, and NPV of Different Assessment Methods for the Prediction of Neoadjuvant Chemotherapy Response in Breast Cancer Abbreviations: Sen, sensitivity; Spe, specificity; PPV, positive predictive value; NPV, negative predictive value; CEUS, contrast-enhanced ultrasound; ABVS, automated breast volume scanner; HDF, high-definition flow; QUS, quantitative ultrasound; ANN, artificial neural network; DOT, diffuse optical tomography. ① Representative ultrasound B-mode images and elastography images for a nonresponder and a responder acquired before and after treatment. (A) Nonresponders typically exhibited no change in tumor elasticity during treatment for several weeks (average strain ratios ranged from 1.29±0.04 before treatment to 1.23±0.11 at week 8). (B) Responders exhibited visibly detectable changes in tumor stiffness (average strain ratios ranged from 1.26±0.11 before treatment to 1.04±0.05 at week 8). Reprinted from Translational Oncology, Vol 6/edition number 1, Falou O, Sadeghi-Naini A, Prematilake S, et al, Evaluation of neoadjuvant chemotherapy response in women with locally advanced breast cancer using ultrasound elastography, Pages No.17–24, Copyright (2013), with permission from Elsevier. 57 ② SWE and corresponding pathologic images from a complete response patient after NAC. (A) The mean tumor stiffness value as determined at baseline was 223.1 kPa. (B) After the second cycle of chemotherapy, the mean tumor stiffness value was 44.7 kPa, and Δ-stiffness was 77.9%. (C and D) Pathological results before chemotherapy and after surgery. Reproduced with permission from Jing H, Cheng W, Li ZY, et al, Early evaluation of relative changes in tumor stiffness by shear wave elastography predicts the response to neoadjuvant chemotherapy in patients with breast cancer and John Wiley & Sons, Inc. © 2016 by the American Institute of Ultrasound in Medicine.72 ③ CEUS and TIC images from a complete response patient after NAC. Before NAC, (A) grayscale US showed a hypoechoic lesion with an irregularly shaped and distinct margin. (A) A CEUS image obtained 39 s after contrast agent injection showed an inhomogeneous hyperenhancement lesion with an indistinct margin. (B) The TIC on CEUS shows strong and rapid perfusion. After NAC, (C) US showed a decrease in the tumor size. (C) CEUS showed hypo-enhancement. (D) The TIC at CEUS shows weak and slow enhancement. Reprinted from European Journal of Radiology, Vol 103, Wan CF, Liu XS, Wang L, Zhang J, Lu JS, Li FH, Quantitative contrast-enhanced ultrasound evaluation of pathological complete response in patients with locally advanced breast cancer receiving neoadjuvant chemotherapy, Pages No. 118–123, Copyright (2018), with permission from Elsevier 49 ④ Example of the ABVS used for response evaluation. Frontal view (anterior-posterior) of the right breast. The left picture shows the tumor (upper left corner) pre-NAC. The right picture shows the same patients mid-NAC with a smaller tumor (upper left corner). Adapted from European Journal of Radiology, Vol 104, van Egdom LSE, Lagendijk M, Heijkoop EHM, et al, Threedimensional ultrasonography of the breast; An adequate replacement for MRI in neoadjuvant chemotherapy tumour response evaluation? - RESPONDER trial, Pages No. 94–100, Copyright (2018), with permission from Elsevier.74 ⑤ Tumor margin obtained on 3D-HDF US images and an established 3D contour. (A) The tumor margin was sketched on a 2D slice B-mode US image, and the 3D contours were then established. The sketched margin is indicated with a blue dotted line. (B) Full image of 3D contours and vascular flow direction of the tumor. Reproduced from Shia WC, Huang YL, Wu HK, Chen DR, Using flow characteristics in three-dimensional power Doppler ultrasound imaging to predict complete responses in patients undergoing neoadjuvant chemotherapy and John Wiley and Sons. © 2017 by the American Institute of Ultrasound in Medicine.80 ⑥ Image of a responder case obtained by using ultrasound-guided diffuse optical tomography. (A and B) US images show US measuring a presize of 3.6 cm and a postsize of 0.7 cm in diameter. (C and D) Pre- and posttreatment reconstructed optical absorption maps show that the lesion was resolved in slices from 1 (top left, left to right) to 7 (bottom left, left to right) and from 2 to 4 (top row, left to right). The pre- and posttreatment THCs were 279.0 μmol/L and 128.0 μmol/L, respectively. The vertical color scale from blue to red is the THC in micromoles per liter from low to high. Reprinted from Translational Oncology, Vol 11/edition number 1, Zhi W, Liu G, Chang C, et al, Predicting treatment response of breast cancer to neoadjuvant chemotherapy using ultrasound-guided diffuse optical tomography, Pages No.56–64, Copyright (2018), with permission from Elsevier.91 ⑦ Changes in peripheral vessels before and after completion of NAC in breast cancer patients displayed by 3D-CEUS. (A) Before NAC, the 3D-CEUS image showed coarse peripheral vessels with radial distribution (arrow) at the strongest stage of perfusion. (B) After completion of NAC, radial peripheral vessels (arrow) disappeared at the strongest stage of perfusion. Reproduced from Jia WR, Tang L,Wang DB, et al. Three-dimensional contrast-enhanced ultrasound in response assessment for breast cancer: a comparison with dynamic contrast-enhanced magnetic resonance imaging and pathology. Sci Rep. 2016;6:33832.81 ⑧ Changes in rim perfusion displayed by 3D-CEUS before and after completion of NAC for another breast cancer patient. (A) Before NAC, 3D-CEUS image showed coarse rim perfusion (arrow) at the strongest stage of perfusion. (B) After completion of NAC, rim perfusion (arrow) disappeared at the strongest stage of perfusion. Reproduced from Jia WR, Tang L,Wang DB, et al. Three-dimensional contrast-enhanced ultrasound in response assessment for breast cancer: a comparison with dynamic contrast-enhanced magnetic resonance imaging and pathology. Sci Rep. 2016;6:33832.81 ⑨ QUS images from a representative non-responder (NR2) patient and a representative responder patient with outlines of core and margin ROIs. (A) B-mode images, (B) SS image, (C) SI images, (D) MBF images, (E) SAS images, (F) ASD, and (G) AAC images obtained prior to chemotherapy treatment initiation. Reproduced from Tadayyon H, Gangeh M, Sannachi L, et al. A priori prediction of breast tumour response to chemotherapy using quantitative ultrasound imaging and artificial neural networks. Oncotarget. 2019;10 (39):3910–3923.88

Conclusions

The goals of NAC have anecdotally been to enable breast conservation and prognostic information. US enables the advantages of portability, low cost, convenient follow-up detection without radiation emission and so on. In general, grayscale US has a low accuracy in the evaluation of the efficacy of NAC, while CEUS, elastography, 3D techniques, and other US techniques (QUS, DOT) can improve the accuracy of prediction. US technology combined with functional examination would be a great development prospect in assessing the response to NAC, and US is expected to be increasingly accepted to predict the efficacy of NAC in the future. However, this paper reviewed only the changes in BC mass after NAC by US and did not examine changes in lymph nodes in the corresponding region. A more detailed review would incorporate the changes in BC masses and lymph nodes observed by US after NAC.
  95 in total

1.  Clinical imaging for the prediction of neoadjuvant chemotherapy response in breast cancer.

Authors:  Mitsuhiro Hayashi; Yutaka Yamamoto; Hirotaka Iwase
Journal:  Chin Clin Oncol       Date:  2020-06

2.  [Detection of liver metastases--comparison of contrast--enhanced ultrasound using first versus second generation contrast agents].

Authors:  T Bernatik; D Becker; D Neureiter; J Hänsler; M Frieser; S Schaber; E G Hahn; D Strobel
Journal:  Ultraschall Med       Date:  2003-06       Impact factor: 6.548

3.  Using Flow Characteristics in Three-Dimensional Power Doppler Ultrasound Imaging to Predict Complete Responses in Patients Undergoing Neoadjuvant Chemotherapy.

Authors:  Wei-Chung Shia; Yu-Len Huang; Hwa-Koon Wu; Dar-Ren Chen
Journal:  J Ultrasound Med       Date:  2017-01-21       Impact factor: 2.153

Review 4.  Role of Magnetic Resonance Imaging in Detection of Pathologic Complete Remission in Breast Cancer Patients Treated With Neoadjuvant Chemotherapy: A Meta-analysis.

Authors:  Yan-Lin Gu; Si-Meng Pan; Jie Ren; Zhi-Xue Yang; Guo-Qin Jiang
Journal:  Clin Breast Cancer       Date:  2017-01-11       Impact factor: 3.225

5.  A new histological grading system to assess response of breast cancers to primary chemotherapy: prognostic significance and survival.

Authors:  Keith N Ogston; Iain D Miller; Simon Payne; Andrew W Hutcheon; Tarun K Sarkar; Ian Smith; A Schofield; Steven D Heys
Journal:  Breast       Date:  2003-10       Impact factor: 4.380

6.  New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1).

Authors:  E A Eisenhauer; P Therasse; J Bogaerts; L H Schwartz; D Sargent; R Ford; J Dancey; S Arbuck; S Gwyther; M Mooney; L Rubinstein; L Shankar; L Dodd; R Kaplan; D Lacombe; J Verweij
Journal:  Eur J Cancer       Date:  2009-01       Impact factor: 9.162

7.  Measurement of residual breast cancer burden to predict survival after neoadjuvant chemotherapy.

Authors:  W Fraser Symmans; Florentia Peintinger; Christos Hatzis; Radhika Rajan; Henry Kuerer; Vicente Valero; Lina Assad; Anna Poniecka; Bryan Hennessy; Marjorie Green; Aman U Buzdar; S Eva Singletary; Gabriel N Hortobagyi; Lajos Pusztai
Journal:  J Clin Oncol       Date:  2007-09-04       Impact factor: 44.544

8.  Amelioration of anxiety, depression, and chemotherapy related toxicity after crocin administration during chemotherapy of breast cancer: A double blind, randomized clinical trial.

Authors:  Roham Salek; Mansoureh Dehghani; Seyed Ahmad Mohajeri; Ali Talaei; Azar Fanipakdel; Seyed Alireza Javadinia
Journal:  Phytother Res       Date:  2021-06-24       Impact factor: 5.878

9.  Breast Cancer Treatment Response Monitoring Using Quantitative Ultrasound and Texture Analysis: Comparative Analysis of Analytical Models.

Authors:  Lakshmanan Sannachi; Mehrdad Gangeh; Hadi Tadayyon; Sonal Gandhi; Frances C Wright; Elzbieta Slodkowska; Belinda Curpen; Ali Sadeghi-Naini; William Tran; Gregory J Czarnota
Journal:  Transl Oncol       Date:  2019-07-17       Impact factor: 4.243

10.  Agreement between MRI and pathologic breast tumor size after neoadjuvant chemotherapy, and comparison with alternative tests: individual patient data meta-analysis.

Authors:  Michael L Marinovich; Petra Macaskill; Les Irwig; Francesco Sardanelli; Eleftherios Mamounas; Gunter von Minckwitz; Valentina Guarneri; Savannah C Partridge; Frances C Wright; Jae Hyuck Choi; Madhumita Bhattacharyya; Laura Martincich; Eren Yeh; Viviana Londero; Nehmat Houssami
Journal:  BMC Cancer       Date:  2015-10-08       Impact factor: 4.430

View more
  1 in total

1.  Development of Gene Expression-Based Random Forest Model for Predicting Neoadjuvant Chemotherapy Response in Triple-Negative Breast Cancer.

Authors:  Seongyong Park; Gwansu Yi
Journal:  Cancers (Basel)       Date:  2022-02-10       Impact factor: 6.639

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.