| Literature DB >> 34694759 |
Amit K Gupta1, Mansi Khanna2, Souradeep Roy1, Shalini Nagabooshanam1, Ranjit Kumar1,3, Shikha Wadhwa1,3, Ashish Mathur1,4.
Abstract
The occurrence of heavy metal ions in food chain is appearing to be a major problem for mankind. The traces of heavy metals, especially Pb(II) ions present in water bodies remains undetected, untreated, and it remains in the food cycle causing serious health hazards for human and livestock. The consumption of Pb(II) ions may lead to serious medical complications including multiple organ failure which can be fatal. The conventional methods of heavy metal detection are costly, time-consuming and require laboratory space. There is an immediate need to develop a cost-effective and portable sensing system which can easily be used by the common man without any technical knowhow. A portable resistive device with miniaturized electronics is developed with microfluidic well and α-MnO2 /GQD nanocomposites as a sensing material for the sensitive detection of Pb(II). α-MnO2 /GQD nanocomposites which can be easily integrated with the miniaturized electronics for real-time on-field applications. The proposed sensor exhibited a tremendous potential to be integrated with conventional water purification appliances (household and commercial) to give an indication of safety index for the drinking water. The developed portable sensor required low sample volume (200 µL) and was assessed within the Pb(II) concentration range of 0.001 nM to 1 uM. The Limit of Detection (LoD) and sensitivity was calculated to be 0.81 nM and 1.05 kΩ/nM/mm2 , and was validated with the commercial impedance analyser. The shelf-life of the portable sensor was found to be ∼45 days.Entities:
Mesh:
Substances:
Year: 2021 PMID: 34694759 PMCID: PMC8675782 DOI: 10.1049/nbt2.12042
Source DB: PubMed Journal: IET Nanobiotechnol ISSN: 1751-8741 Impact factor: 2.050
FIGURE 1Schematic of nanosensor fabrication and the Pb(II) detection strategy using portable resistive device and validation with the impedance analyser (EIS)
FIGURE 2(a) SEM micrograph recorded at 20 keV, (b) EDX spectrum, (c) TEM image obtained at 120 keV, (d) FTIR spectrum obtained within 4000 cm−1 to 500 cm−1 of α‐MnO2/GQD nanocomposites
FIGURE 3(a) Sensor calibration of Pb(II) detection (0.001 nM–1 μM) at 500 mV using portable resistive device, (b) Shelf‐life analysis of Pb(II) sensor performed over 50 days at regular intervals of 5 days 1 μM Pb(II) has been used for shelf‐life studies
FIGURE 4(a) Nyquist plot at various Pb(II) concentrations in the range 100 Hz–1 MHz at 100 mV AC, (b) Sensor calibration within 0.001 nM–1 μM Pb(II) at 20 kHz, (c) Nyquist spectra of Pb, Cd, DBF (Dibenzofuran) and BPA (Bisphenol‐A) highlighting the effects of potential interferants towards Pb detection. The concentration of each of the chosen compounds for interference analysis is 1 µM
Comparison of LoD and sensitivity calculated using the EIS and the developed portable Pb(II) monitoring device
| Sl. No | Pb(II) Sensing Strategy Employed | LoD (nM) | Sensitivity (kΩ/nM/mm2) |
|---|---|---|---|
| 1 | Portable resistive device | 0.81 | 1.05 |
| 2 | Commercial EIS | 0.84 | 0.53 |
A comparison of the developed Pb(II) sensors with those reported in the literature
| Electrode | Detection Technique | LOD (μg L−1) | Reference |
|---|---|---|---|
| Bi/poly(1,8‐diaminonaphthalene) modified carbon paste electrode | SWV | 0.3 | [ |
| Bi nanoparticles/Nafion®‐modified pencil graphite electrodes | ASV | 31.1 | [ |
| Screen‐printed carbon electrodes | SWASV | 2.0 | [ |
| Cu electrode | ASV | 4.4 | [ |
| Bi–C nanocomposite | SWASV | 0.7 | [ |
| BiNPs | SWASV | 2.0 | [ |
| CoFe2O4/Bi nanocomposite | SWASV | 1.5 | [ |
| SWCNT/screen printed electrodes | SWASV | 0.4 | [ |
| α‐MnO2/GQD/Au electrodes | EIS | 0.3 (0.81 nM) | Present work |
*ASV = Anodic stripping voltammetry; SWV = Square wave voltammetry; SWASV = Square wave anodic stripping voltammetry.