| Literature DB >> 34674449 |
Akira Higashimori1, Yuji Nadatani1, Hirotsugu Maruyama1, Yasuhiro Fujiwara1.
Abstract
Entities:
Year: 2021 PMID: 34674449 PMCID: PMC9329639 DOI: 10.5946/ce.2021.175
Source DB: PubMed Journal: Clin Endosc ISSN: 2234-2400
Fig. 1.Overview photographs for tested devices. (A) Modified mask. (B) Vinyl box with continuous suction. (C) Vinyl box without suction. (D) Aerosol box.
Fig. 2.Comparison of the total amount of airborne particles among the different experimental conditions. (A) Time series chart of each intervention over the 6 min experimental period. Lines represent the median total particle count (0.3–2 µm) of six separate trials. Coughs were generated every 30 seconds through the experimental period. (B) The number of total airborne particles during the simulation is shown on a scatter plot with medians and interquartile ranges. n=432. **p<0.01 (versus no device use). n.s, not significant.
Comparison of endoscopist exposure of total particles between four aerosol containment devises, no device use, and baseline
| Baseline | No devise use | Modified mask | Vinyl-box with suction | Vinyl-box without suction | Aerosol box | |
|---|---|---|---|---|---|---|
| Total particle amount | 322,324 (313,711-332,993) | 370,817 (350,303-433,071) | 327,693 (334,670-342,485) | 333,120 (327,103-337,072) | 346,822 (340,451-355,023) | 378,030 (361,893-396,436) |
| Baseline | - | <0.001 | 0.37 | 0.73 | <0.001 | <0.001 |
| No device use | <0.001 | - | <0.001 | <0.001 | <0.001 | 0.61 |
| Modified mask | 0.37 | <0.001 | - | 0.99 | 0.08 | <0.001 |
| Vinyl-box with suction | 0.73 | <0.001 | 0.99 | - | 0.02 | <0.001 |
| Vinyl-box without suction | <0.001 | <0.001 | 0.08 | 0.02 | - | <0.001 |
| Aerosol box | <0.001 | 0.61 | <0.001 | <0.001 | <0.001 | - |
Values are presented as median (interquartile range).