OBJECTIVES: To evaluate the effect of the position of microcoil proximal end on the incidence of microcoil dislocation during CT-guided microcoil localization of pulmonary nodules (PNs). METHODS: This retrospective study included all patients with PNs who received CT-guided microcoil localization before video-assisted thoracoscopic urgery (VATS) resection from June 2016 to December 2019 in our institution. The microcoil distal end was less than 1 cm away from the nodule, and the microcoil proximal end was in the pleural cavity (the pleural cavity group) or chest wall (the chest wall group). The length of microcoil outside the pleura was measured and divided into less than 0.5 cm (group A), 0.5 to 2 cm (group B) and more than 2 cm (group C). Microcoil dislocation was defined as complete retraction into the lung (type I) or complete withdrawal from the lung (type II). The rate of microcoil dislocation between different groups was compared. RESULTS: A total of 519 consecutive patients with 571 PNs were included in this study. According to the position of microcoils proximal end on post-marking CT, there were 95 microcoils in the pleural cavity group and 476 in the chest wall group. The number of microcoils in group A, B, and C were 67, 448 and 56, respectively. VATS showed dislocation of 42 microcoils, of which 30 were type II and 12 were type I. There was no statistical difference in the rate of microcoil dislocation between the pleural cavity group and the chest wall group (6.3% vs 7.6%, x2 = 0.18, p = 0.433). The difference in the rate of microcoil dislocation among group A, B, and C was statistically significant (11.9%, 5.8%, and 14.3% for group A, B, and C, respectively, x2 = 7.60, p = 0.008). In group A, 75% (6/8) of dislocations were type I, while all eight dislocations were type II in group C. CONCLUSIONS: During CT-guided microcoil localization of PNs, placing the microcoil proximal end in the pleura cavity or chest wall had no significant effect on the incidence of microcoil dislocation. The length of microcoil outside the pleura should be 0.5 to 2 cm to reduce the rate of microcoil dislocation. ADVANCES IN KNOWLEDGE:: CT-guided microcoil localization can effectively guide VATS to resect invisible and impalpable PNs. Microcoil dislocation is the main cause of localization failure. The length of microcoil outside the pleura is significantly correlated with the rate and type of microcoil dislocation. Placing the microcoil proximal end in the pleura cavity or chest wall has no significant effect on the rate of microcoil dislocation.
OBJECTIVES: To evaluate the effect of the position of microcoil proximal end on the incidence of microcoil dislocation during CT-guided microcoil localization of pulmonary nodules (PNs). METHODS: This retrospective study included all patients with PNs who received CT-guided microcoil localization before video-assisted thoracoscopic urgery (VATS) resection from June 2016 to December 2019 in our institution. The microcoil distal end was less than 1 cm away from the nodule, and the microcoil proximal end was in the pleural cavity (the pleural cavity group) or chest wall (the chest wall group). The length of microcoil outside the pleura was measured and divided into less than 0.5 cm (group A), 0.5 to 2 cm (group B) and more than 2 cm (group C). Microcoil dislocation was defined as complete retraction into the lung (type I) or complete withdrawal from the lung (type II). The rate of microcoil dislocation between different groups was compared. RESULTS: A total of 519 consecutive patients with 571 PNs were included in this study. According to the position of microcoils proximal end on post-marking CT, there were 95 microcoils in the pleural cavity group and 476 in the chest wall group. The number of microcoils in group A, B, and C were 67, 448 and 56, respectively. VATS showed dislocation of 42 microcoils, of which 30 were type II and 12 were type I. There was no statistical difference in the rate of microcoil dislocation between the pleural cavity group and the chest wall group (6.3% vs 7.6%, x2 = 0.18, p = 0.433). The difference in the rate of microcoil dislocation among group A, B, and C was statistically significant (11.9%, 5.8%, and 14.3% for group A, B, and C, respectively, x2 = 7.60, p = 0.008). In group A, 75% (6/8) of dislocations were type I, while all eight dislocations were type II in group C. CONCLUSIONS: During CT-guided microcoil localization of PNs, placing the microcoil proximal end in the pleura cavity or chest wall had no significant effect on the incidence of microcoil dislocation. The length of microcoil outside the pleura should be 0.5 to 2 cm to reduce the rate of microcoil dislocation. ADVANCES IN KNOWLEDGE:: CT-guided microcoil localization can effectively guide VATS to resect invisible and impalpable PNs. Microcoil dislocation is the main cause of localization failure. The length of microcoil outside the pleura is significantly correlated with the rate and type of microcoil dislocation. Placing the microcoil proximal end in the pleura cavity or chest wall has no significant effect on the rate of microcoil dislocation.
Authors: Subroto Paul; Nasser K Altorki; Shubin Sheng; Paul C Lee; David H Harpole; Mark W Onaitis; Brendon M Stiles; Jeffrey L Port; Thomas A D'Amico Journal: J Thorac Cardiovasc Surg Date: 2010-02 Impact factor: 5.209
Authors: Theo J Klinkenberg; Lars Dinjens; Rienhart F E Wolf; Anthonie J van der Wekken; Caroline van de Wauwer; Geertruida H de Bock; Wim Timens; Massimo A Mariani; Harry J M Groen Journal: J Surg Oncol Date: 2017-02-23 Impact factor: 3.454
Authors: Jason K Lempel; Daniel P Raymond; Usman Ahmad; Susan O'Malley; Michael A Bolen; Ruffin Graham; Joseph T Azok; Jennifer Bullen; Siva Raja; Sudish Murthy Journal: J Vasc Interv Radiol Date: 2018-08-31 Impact factor: 3.464
Authors: Laura L Donahoe; Elsie T Nguyen; Tae-Bong Chung; Lan-Chau Kha; Marcelo Cypel; Gail E Darling; Marc de Perrot; Shaf Keshavjee; Andrew F Pierre; Thomas K Waddell; Kazuhiro Yasufuku Journal: J Thorac Dis Date: 2016-08 Impact factor: 2.895
Authors: Jonathan C L Rodrigues; Andrew F Pierre; Kate Hanneman; Michael Cabanero; John Kavanagh; Thomas K Waddell; Tae-Bong Chung; Mini Pakkal; Shaf Keshavjee; Marcelo Cypel; Kazuhiro Yasufuku; Elsie T Nguyen Journal: Radiology Date: 2019-02-05 Impact factor: 11.105
Authors: Lan-Chau T Kha; Kate Hanneman; Laura Donahoe; Taebong Chung; Andrew F Pierre; Kazuhiro Yasufuku; Shafique Keshavjee; John R Mayo; Narinder S Paul; Elsie T Nguyen Journal: J Thorac Imaging Date: 2016-01 Impact factor: 3.000