Literature DB >> 346162

Serum ionised calcium concentration: measurement versus calculation.

S C Conceicao, D Weightman, P A Smith, J Luno, M K Ward, D N Kerr.   

Abstract

Four hundred and eighteen measurements of serum ionised calcium, total calcium, and protein concentrations were made from 47 normal volunteers, 104 patients with chronic renal failure (33 being treated conservatively and 71 with regular haemodialysis), and 83 renal transplant recipients. The serum ionised calcium concentration was measured with an Orion SS-20 meter and calculated from the total serum calcium and protein concentrations by using three formulae and a nomogram. In the normal subjects and patients undergoing regular haemodialysis, whose serum calcium concentrations were in or near the normal range, three of the calculations gave results similar to those obtained by direct measurement. In patients with conservatively treated chronic renal failure and those who had received renal transplants, however, there was poor aggrement between the methods. When patients with hypercalcaemia and hypocalcaemia from all the groups were considered separately there was again poor agreement between calculated and measured concentrations of serum ionised calcium. Of the patients whose measured concentrations of serum ionised calcium were high, 69-76% were classified as normal by the four indirect methods. We conclude that calculation of the serum ionised calcium concentrations is not an adequate substitute for direct measurement.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 346162      PMCID: PMC1604303          DOI: 10.1136/bmj.1.6120.1103

Source DB:  PubMed          Journal:  Br Med J        ISSN: 0007-1447


  6 in total

1.  Evaluation of a new automatic calcium ion analyzer.

Authors:  S Madsen; K Olgaard
Journal:  Clin Chem       Date:  1977       Impact factor: 8.327

2.  Determination of diffusible serum calcium.

Authors:  E B ZEISLER
Journal:  Am J Clin Pathol       Date:  1954-05       Impact factor: 2.493

3.  Measurement of serum and plasma ionic calcium with the "Space-Stat 20 Ionized Calcium Analyzer".

Authors:  H Husdan; M Leung; D Oreopoulos; A Rapoport
Journal:  Clin Chem       Date:  1977-09       Impact factor: 8.327

4.  CONSTRUCTION OF A CARTESIAN NOMOGRAM FOR THE LAW OF MASS ACTION.

Authors:  F C McLean
Journal:  Science       Date:  1935-08-02       Impact factor: 47.728

5.  Letter: Adjustment of plasma calcium measurements.

Authors:  R W Marshall; B E Nordin
Journal:  Br Med J       Date:  1974-06-29

6.  Variation in plasma calcium with induced changes in plasma specific gravity, total protein, and albumin.

Authors:  E M Berry; M M Gupta; S J Turner; R R Burns
Journal:  Br Med J       Date:  1973-12-15
  6 in total
  10 in total

1.  Serum calcium measurement: Total versus free (ionized) calcium.

Authors:  Laxmayya Sava; Sandhya Pillai; Umesh More; Alka Sontakke
Journal:  Indian J Clin Biochem       Date:  2005-07

2.  Serum intact parathyroid hormone and ionised calcium concentration in children with renal insufficiency.

Authors:  S E Ledermann; A Johnson; M J Dillon; R S Trompeter; T M Barratt
Journal:  Pediatr Nephrol       Date:  1994-10       Impact factor: 3.714

3.  Measuring serum calcium.

Authors:  J A Kanis; A J Yates
Journal:  Br Med J (Clin Res Ed)       Date:  1985-03-09

4.  Ionised calcium in rheumatoid arthritis: effect of non-steroidal anti-inflammatory drugs.

Authors:  M G Bramble; D R Blake; T White; J Sly; D N Kerr
Journal:  Br Med J       Date:  1980-09-27

5.  Continuous in vivo measurement of plasma ionized calcium.

Authors:  R Greger; H Oberleithner; F Lang; H Sporer
Journal:  Pflugers Arch       Date:  1980-03       Impact factor: 3.657

6.  Is the routine measurement of ionized calcium worthwhile in patients with cancer?

Authors:  J A Riancho; R Arjona; J Sanz; J M Olmos; R Valle; J R Barceló; J González-Macías
Journal:  Postgrad Med J       Date:  1991-04       Impact factor: 2.401

7.  Serum calcium levels in rheumatoid arthritis.

Authors:  D L Scott; M Farr; C F Hawkins; R Wilkinson; A M Bold
Journal:  Ann Rheum Dis       Date:  1981-12       Impact factor: 19.103

8.  Osteopenia with decreased bone formation in beagles with malabsorption syndrome.

Authors:  B N Kunkle; R W Norrdin; R K Brooks; R W Thomassen
Journal:  Calcif Tissue Int       Date:  1982-07       Impact factor: 4.333

9.  Continuous ambulatory peritoneal dialysis: one year's experience in a UK dialysis unit.

Authors:  R Gokal; M McHugh; R Fryer; M K Ward; D N Kerr
Journal:  Br Med J       Date:  1980-08-16

10.  Incidence of hypercalcaemia and primary hyperparathyroidism in relation to the biochemical profile.

Authors:  J S Harrop; J E Bailey; J S Woodhead
Journal:  J Clin Pathol       Date:  1982-04       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.