Literature DB >> 34612175

Particle-phase collection efficiency of the OVS and IFV Pro personal pesticide samplers.

Shaunae Alex1, Matthew Sovers1, Patrick T O'Shaughnessy1.   

Abstract

The inhalable aerosol sampling criterion has been developed to characterize the efficiency of particles entering the nose and/or mouth. However, pesticides can exist in the air in both vapor and particulate phases, which complicates exposure assessments. The American Conference of Governmental Industrial Hygienists (ACGIH) has established an IFV (inhalable fraction and vapor) endnote for chemicals such as many pesticides that need to be evaluated for both their inhalable fraction and vapor concentrations to fully characterize worker exposures. The purpose of this study was to evaluate the particle-phase collection efficiency of a commonly-used pesticide sampler, the OSHA Versatile Sampler (OVS) as well as a recently developed sampler, the IFV Pro. The OVS was not designed as an inhalable aerosol sampler, whereas the IFV Pro contains a sampling head scaled to that of the Institute of Medicine (IOM) sampler, which is known to closely follow the inhalable sampling criterion. Laboratory experiments involving a vertical-flow, low-velocity scheme, and finely graded test dusts with known median aerodynamic diameter were used to determine sampler collection efficiencies. The collection efficiency of the OVS was evaluated as recommended by the manufacturer and after two modifications made to potentially improve its collection efficiency. The OVS was found to substantially under-sample relative to the inhalable criterion, and the two modifications did not provide substantial improvements to the original configuration. Conversely, the collection efficiency of the IFV Pro was found to compare closely to that of the IOM, although collecting 9% more mass. When applied side-by-side with the OVS sampler in a chamber into which ethylene glycol was sprayed as a proxy for a pesticide, the IFV Pro collected an average of 1.9-fold more mass than the OVS for the same flow rate and sample time.

Entities:  

Keywords:  Efficiency; inhalable; pesticides; samplers

Mesh:

Substances:

Year:  2021        PMID: 34612175      PMCID: PMC8755619          DOI: 10.1080/15459624.2021.1989443

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  12 in total

Review 1.  New experimental methods for the development and evaluation of aerosol samplers.

Authors:  Laurie A Brixey; Samuel Y Paik; Douglas E Evans; James H Vincent
Journal:  J Environ Monit       Date:  2002-10

2.  Pesticide aerosol characteristics in the vicinity of an agricultural vehicle cab during application.

Authors:  Denis Bémer; Joelle Fismes; Isabelle Subra; Veronique Blachère; Jean-Claude Protois
Journal:  J Occup Environ Hyg       Date:  2007-07       Impact factor: 2.155

3.  Laboratory study of selected personal inhalable aerosol samplers.

Authors:  Peter Görner; Xavier Simon; Richard Wrobel; Edmond Kauffer; Olivier Witschger
Journal:  Ann Occup Hyg       Date:  2010-02-10

4.  A collaborative European study of personal inhalable aerosol sampler performance.

Authors:  L C Kenny; R Aitken; C Chalmers; J F Fabriès; E Gonzalez-Fernandez; H Kromhout; G Lidén; D Mark; G Riediger; V Prodi
Journal:  Ann Occup Hyg       Date:  1997-04

5.  Development and field testing of a miniaturized sampling system for simultaneous sampling of vapours and droplets.

Authors:  Dietmar Breuer; George C Dragan; Claudia Friedrich; Carsten Möhlmann; Ralf Zimmermann
Journal:  Environ Sci Process Impacts       Date:  2015-02       Impact factor: 4.238

6.  Proposed international conventions for particle size-selective sampling.

Authors:  S C Soderholm
Journal:  Ann Occup Hyg       Date:  1989

7.  A new personal sampler for airborne total dust in workplaces.

Authors:  D Mark; J H Vincent
Journal:  Ann Occup Hyg       Date:  1986

Review 8.  Oral bioaccessibility of semi-volatile organic compounds (SVOCs) in settled dust: A review of measurement methods, data and influencing factors.

Authors:  Gaëlle Raffy; Fabien Mercier; Philippe Glorennec; Corinne Mandin; Barbara Le Bot
Journal:  J Hazard Mater       Date:  2018-03-21       Impact factor: 10.588

9.  Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

Authors:  Zuocheng Wang; Leonardo Calderón; Allison P Patton; MaryAnn Sorensen Allacci; Jennifer Senick; Richard Wener; Clinton J Andrews; Gediminas Mainelis
Journal:  J Air Waste Manag Assoc       Date:  2016-11       Impact factor: 2.235

10.  Spray Droplet Characterization from a Single Nozzle by High Speed Image Analysis Using an In-Focus Droplet Criterion.

Authors:  Sofija Vulgarakis Minov; Frédéric Cointault; Jürgen Vangeyte; Jan G Pieters; David Nuyttens
Journal:  Sensors (Basel)       Date:  2016-02-06       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.