Literature DB >> 3457347

The effects of cyclical axial motion on rotary endodontic instrument fatigue.

D N Dederich, K L Zakariasen.   

Abstract

A potential problem with the use of rotary engine-driven files to flare canals is metal fatigue and subsequent breakage. This study analyzes the effects of cyclical axial motion on instrument failure by fatigue testing of endodontic files with and without cyclical axial motion. Eighteen new instruments, sizes 15 to 45, were mounted in a lathe and turned at 1650 rpm in the lubricated lumen of a curved Pyrex capillary tube until failure occurred. Nine instruments of each size were turned with cyclical axial motion and nine were turned without it. The results indicated that cyclical axial motion can significantly extend the life span of rotary engine files. Torsional forces were not considered in this study.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3457347     DOI: 10.1016/0030-4220(86)90186-6

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  5 in total

1.  Influence of axial movement on fatigue of ProFile Ni-Ti rotary instruments: an in vitro evaluation.

Authors:  Marie-Chantal Avoaka; Youssef Haïkel
Journal:  Bosn J Basic Med Sci       Date:  2010-05       Impact factor: 3.363

2.  An in vitro evaluation of the effect of deep dry cryotreatment on the cutting efficiency of three rotary nickel titanium instruments.

Authors:  Gingu Koshy George; Kavitha Sanjeev; Mahalaxmi Sekar
Journal:  J Conserv Dent       Date:  2011-04

3.  Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files.

Authors:  Álvaro Zubizarreta-Macho; Jesús Mena Álvarez; Alberto Albaladejo Martínez; Juan José Segura-Egea; Javier Caviedes Brucheli; Rubén Agustín-Panadero; Roberto López Píriz; Óscar Alonso-Ezpeleta
Journal:  J Clin Med       Date:  2019-12-24       Impact factor: 4.241

4.  Mechanical Properties of ProTaper Gold, EdgeTaper Platinum, Flex Gold and Pro-T Rotary Systems.

Authors:  Murilo Alcalde; Marco Antonio Hungaro Duarte; Pablo Andrés Amoroso Silva; Pedro Henrique Souza Calefi; Emmanuel Silva; Jussaro Duque; Rodrigo Vivan
Journal:  Eur Endod J       Date:  2020-12

5.  Influence of Sodium Hypochlorite and Chlorhexidine on the Dynamic Cyclic Fatigue Resistance of XP Endo Shaper Instruments.

Authors:  Alexandra Aparecida Tanomaru; Ana Grasiela Limoeiro; Adriana de Jesus Soares; Elson Lopes Medeiros Junior; Gabriel Rocha Campos; Sílvia Kaoru Hamasaki; Wayne Martins Nascimento; Luiz Meton Horta; Paula Avelar da Silva Ribeiro Goulart; Viviane Rangel do Couto; Patrícia Bastos Alves; Verônica Magalhães; Danilo De Luca Campos; Marcos Frozoni
Journal:  Eur J Dent       Date:  2021-12-22
  5 in total