Topographic and tomographic changes of keratoconus and postrefractive surgery ectasia are expected to be preceded by a corneal biomechanical weakening.[1] The field of corneal biomechanics has been gaining interest in the last couple of decades for the early detection of keratoconus and postrefractive surgery ectasias, among several other reasons, which include assessment of different cross-linking techniques and myopia progression in children. The assessment and interpretation of corneal biomechanics depends on the device used. Ocular response analyzer (ORA) and corneal visualization Scheimpflug technology (CORVIS ST) are the two main devices used clinically to study biomechanics in vivo. ORA has been reported to have lesser sensitivity and specificity in detecting biomechanical weakening, and in recent years, most studies are performed using CORVIS ST. The main research questions when it comes to the field of refractive surgery are i) Which procedure is biomechanically stronger, ii) Differentiating normal corneas postrefractive surgery from postrefractive surgery ectasia, and iii) Predicting postrefractive surgery ectasia earlier. Before we delve into the individual questions, we need to understand certain basics while interpreting CORVIS ST biomechanical outputs. i) Several two-dimensional univariate values measuring biomechanics such as DA, A1, and A2 are prone to be affected by CCT (corneal thickness) and IOP; just because a cornea is thinner or has a lower distending IOP, the tissue may be interpreted as weaker despite the strength being normal. Therefore, we must choose to utilize multivariate indices which are independent of CCT and IOP. ii) Interpretation of corneal biomechanics should not consider only the corneal center, but the whole of the cornea and the influence of whole globe biomechanics as well. For example, biomechanics of the corneal center may not reflect a peripheral corneal ectasia earlier and likewise, a weaker or stronger scleral wall is known to influence the deformation amplitude of the cornea. Finite element modelling (FEM)-based index such as Stress Strain Index (SSI) is the first in this right direction.[2] SSI is not influenced by CCT or IOP and represents the actual strength of the cornea in lay man terms. Which procedure is biomechanically stronger? There have been several studies done using ORA and CORVIS to study biomechanical changes post LASIK, PRK, and SMILE. Though earlier studies using ORA have shown that LASIK has a greater biomechanical weakening compared to SMILE,[3] recent studies using CORVIS ST have variable conclusions.[45] When LASIK and SMILE are matched for the changes in CCT, they have shown similar biomechanical weakening.[6] There is only one study now showing SSI changes in early postoperative time following LASIK.[7] There are more studies needed using the novel SSI and CBI-LVC with longer-term follow ups and also involve the effects of long-term wound healing to check how LASIK differs from SMILE. Differentiating normal corneas postrefractive surgery from post refractive surgery ectasia Though several univariate indices provided by CORVIS ST have been variably successful in differentiating normal corneas from postrefractive surgery ectatic ones in the past, the best index as on date is the CBI-LVC, with sensitivity and specificity over 90% for a cutoff of 0.20.[8] For all corneas postrefractive surgery, surgeons must use this index which is different from CBI to build a larger database, so that this index can be further tested and refined. Predicting postrefractive surgery ectasia earlier: The existing indices from CORVIS ST can help differentiate a cornea which is biomechanically weaker from a normal cornea, adjusting for CCT and IOP. However, they cannot predict how much a laser refractive procedure can weaken a particular cornea. There is a relatively newer published work on predictive modelling using FEM,[9] and also a software called “AcuSimX” which can help predict the level of biomechanical weakening a cornea undergoing a specific form of refractive surgery develops. This tool needs to be studied and compared with the actual measured long-term biomechanical weakening postrefractive surgery, denoted by CBI-LVC and SSI. This can be a significant value addition in the field of refractive surgery, which can let the surgeon know the risk of ectasia preoperatively itself. Finally, there are newer devices, which are not commercially available until now, such as polarization sensitive OCT,[10] which can visualize the collagen distribution within the cornea and identify weakening. Results from these devices, when studied and interpreted along with the advancements above, are likely to revolutionize our understanding of corneal biomechanics in the near future.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  9 in total

1.  In Vivo Prediction of Air-Puff Induced Corneal Deformation Using LASIK, SMILE, and PRK Finite Element Simulations.

Authors:  Mathew Francis; Pooja Khamar; Rohit Shetty; Kanchan Sainani; Rudy M M A Nuijts; Bart Haex; Abhijit Sinha Roy
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-11-01       Impact factor: 4.799

2.  Changes in corneal biomechanics during small-incision lenticule extraction (SMILE) and femtosecond-assisted laser in situ keratomileusis (FS-LASIK).

Authors:  Kaiwei Cao; Lina Liu; Ting Yu; Feng Chen; Ji Bai; Ting Liu
Journal:  Lasers Med Sci       Date:  2019-08-29       Impact factor: 3.161

3.  Title.

Authors:  Riccardo Vinciguerra; Renato Ambrósio; Ahmed Elsheikh; Farhad Hafezi; David Sung Yong Kang; Omid Kermani; Shizuka Koh; Nanji Lu; Prema Padmanabhan; Cynthia J Roberts; Suphi Taneri; William Trattler; Paolo Vinciguerra
Journal:  J Cataract Refract Surg       Date:  2021-02-24       Impact factor: 3.351

4.  Comparison of corneal biomechanical changes after LASIK and F-SMILE with CorVis ST.

Authors:  Eman A Abd El-Fattah; Alaa A El Dorghamy; Ahmed M Ghoneim; Hisham A Saad
Journal:  Eur J Ophthalmol       Date:  2020-07-22       Impact factor: 2.597

5.  Biomechanics of LASIK Flap and SMILE Cap: A Prospective, Clinical Study.

Authors:  Pooja Khamar; Rohit Shetty; Ravish Vaishnav; Mathew Francis; Rudy M M A Nuijts; Abhijit Sinha Roy
Journal:  J Refract Surg       Date:  2019-05-01       Impact factor: 3.573

6.  Determination of Corneal Biomechanical Behavior in-vivo for Healthy Eyes Using CorVis ST Tonometry: Stress-Strain Index.

Authors:  Ashkan Eliasy; Kai-Jung Chen; Riccardo Vinciguerra; Bernardo T Lopes; Ahmed Abass; Paolo Vinciguerra; Renato Ambrósio; Cynthia J Roberts; Ahmed Elsheikh
Journal:  Front Bioeng Biotechnol       Date:  2019-05-16

7.  Ultrahigh Resolution Polarization Sensitive Optical Coherence Tomography of the Human Cornea with Conical Scanning Pattern and Variable Dispersion Compensation.

Authors:  Florian Beer; Rahul P Patil; Abhijit Sinha-Roy; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Appl Sci (Basel)       Date:  2019-10-11       Impact factor: 2.679

8.  Short term changes in corneal stress-strain index and other corneal biomechanical parameters post-laser in situ keratomileusis.

Authors:  Vaishal P Kenia; Raj V Kenia; Onkar H Pirdankar
Journal:  Indian J Ophthalmol       Date:  2021-10       Impact factor: 1.848

9.  Corneal biomechanical properties after SMILE versus FLEX, LASIK, LASEK, or PRK: a systematic review and meta-analysis.

Authors:  Hui Guo; Seyed M Hosseini-Moghaddam; William Hodge
Journal:  BMC Ophthalmol       Date:  2019-08-01       Impact factor: 2.209