Literature DB >> 34554568

X-ray bi-prism interferometry-A design study of proposed novel hardware.

Grant T Gullberg1, Uttam Shrestha1, Sally Ji Who Kim2, Youngho Seo1, Michael Fuller3.   

Abstract

PURPOSE: Advances in X-ray phase-contrast imaging can obtain excellent soft-tissue contrast of phase-shift, attenuation, and small-angle scatter. Here, we present fringe patterns for different design parameters of X-ray bi-prism interferometry imaging systems. Our aim is to develop bi-prism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. We also introduce a novel X-ray tube design that uses temporal multiplexing to provide simultaneous virtual "electronic phase stepping" that replace "mechanical phase stepping" popular with grating-based interferometry setups.
METHODS: In our investigation, we develop expressions for the irradiance distribution pattern of a bi-prism interferometer composed of multiple point sources and multiple bi-prisms. These expressions are used to plot fringe patterns for X-ray design parameters, including size of point source, number of point sources, and point source separation, and bi-prism design parameters including material, angle, number of bi-prisms, period, and bi-prism array to X-ray source and detector distances.
RESULTS: Results show that the fringe patterns for a bi-prism interferometry system are not longitudinally periodic as with grating interferometers that produce a Talbot-Lau carpet. It is also shown that at 59 keV X-rays the bi-prism material should be something comparable to nickel to obtain reasonable fringe visibility.
CONCLUSION: The irradiance distribution pattern demonstrates that bi-prism interferometry may provide comparable or improved fringe visibility to that of gratings. Special care is given to present our findings within the context of previous advancements. A single-shot image acquisition approach using a temporal multiplexed, high-power X-ray source provides virtual electronic phase stepping without focal spot sweeping. This provides multiple images, each at the same exposure and the same projection view, from different fringe locations that allow one to derive the attenuation, phase, and dark-field images of the sample without mechanical phase stepping of a grating.
© 2021 American Association of Physicists in Medicine.

Entities:  

Keywords:  X-ray phase-contrast imaging; X-ray tube design; bi-prism interferometry; dark-field imaging; small-angle scatter

Mesh:

Year:  2021        PMID: 34554568      PMCID: PMC8614238          DOI: 10.1002/mp.15241

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.506


  20 in total

1.  Moiré interferogram phase extraction: a ridge detection algorithm for continuous wavelet transforms.

Authors:  Heng Liu; Alexander N Cartwright; Cemal Basaran
Journal:  Appl Opt       Date:  2004-02-01       Impact factor: 1.980

2.  A bi-prism interferometer for hard X-ray photons.

Authors:  A F Isakovic; A Stein; J B Warren; A R Sandy; S Narayanan; M Sprung; J M Ablett; D P Siddons; M Metzler; K Evans-Lutterodt
Journal:  J Synchrotron Radiat       Date:  2010-05-18       Impact factor: 2.616

3.  A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging.

Authors:  Eric E Bennett; Rael Kopace; Ashley F Stein; Han Wen
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

4.  Motionless phase stepping in X-ray phase contrast imaging with a compact source.

Authors:  Houxun Miao; Lei Chen; Eric E Bennett; Nick M Adamo; Andrew A Gomella; Alexa M DeLuca; Ajay Patel; Nicole Y Morgan; Han Wen
Journal:  Proc Natl Acad Sci U S A       Date:  2013-11-11       Impact factor: 11.205

5.  Tensor Tomography of Dark Field Scatter using X-ray Interferometry with Bi-prisms.

Authors:  Grant T Gullberg; Michael Fuller; Uttam Shrestha; Youngho Seo
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2018-11-15

6.  Axial resonance of periodic patterns by using a Fresnel biprism.

Authors:  Ana Doblas; Genaro Saavedra; Manuel Martinez-Corral; Juan C Barreiro; Emilio Sanchez-Ortiga; Anabel Llavador
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2013-01-01       Impact factor: 2.129

7.  Non-binary phase gratings for x-ray imaging with a compact Talbot interferometer.

Authors:  Andre Yaroshenko; Martin Bech; Guillaume Potdevin; Andreas Malecki; Thomas Biernath; Johannes Wolf; Arne Tapfer; Markus Schüttler; Jan Meiser; Danays Kunka; Maximilian Amberger; Juergen Mohr; Franz Pfeiffer
Journal:  Opt Express       Date:  2014-01-13       Impact factor: 3.894

Review 8.  X-ray phase imaging reaching clinical uses.

Authors:  Atsushi Momose
Journal:  Phys Med       Date:  2020-11-17       Impact factor: 2.685

9.  A Universal Moiré Effect and Application in X-Ray Phase-Contrast Imaging.

Authors:  Houxun Miao; Alireza Panna; Andrew A Gomella; Eric E Bennett; Sami Znati; Lei Chen; Han Wen
Journal:  Nat Phys       Date:  2016-04-25       Impact factor: 20.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.